Industrial and process control, distributed power, medical, ATE, communications,
defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V375C12T150BL2
375C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
V
OUT
P
OUT
2V
50W
3.3V
50W, 75W
5V
50W, 100W
8V
100W
12V
75W, 150W
15V
75W, 150W
24V
75W, 150W
28V
75W, 150W
36V
75W, 150W
48V
75W, 150W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
2
= N/A
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
375V Micro Family
Page 1 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
375V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
204.7
429.2
242.5
212.2
446.3
467.5
1.1
Min
250
Typ
375
Max
425
500
247.5
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
+OUT to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
375V Micro Family
Page 2 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
375V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
.
375V Micro Family
Page 3 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
375V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
2V
OUT
, 50W (e.g. S375C2C50BL, V375C2C50BL)
Parameter
Efficiency
S375C2C50BL (enhanced efficiency)
V375C2C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
78.0
72
2.7
Typ
81.0
73.9
80
2.8
2.5
±0.02
28.8
28.8
Max
Unit
%
100
2.9
3.5
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
3.3V
OUT
, 75W (e.g. S375C3V3C75BL, V375C3V3C75BL)
Parameter
Efficiency
S375C3V3C75BL (enhanced efficiency)
V375C3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
79.0
4.14
Typ
85.0
80.5
94
4.3
3.9
±0.02
24.6
24.6
Max
Unit
%
118
4.46
5.9
±0.4
22.7
30.6
30.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
3.3V
OUT
, 50W (e.g. S375C3V3C50BL, V375C3V3C50BL)
Parameter
Efficiency
S375C3V3C50BL (enhanced efficiency)
V375C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.0
75.7
4.14
Typ
83.0
77
140
4.3
3.4
±0.02
17.5
17.5
Max
Unit
%
175
4.46
4
±0.2
15.15
20.6
20.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 100W (e.g. S375C5C100BL, V375C5C100BL)
Parameter
Efficiency
S375C5C100BL (enhanced efficiency)
V375C5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.3
80
6.03
Typ
82.3
81.8
120
6.25
3.1
±0.02
23
23
Max
Unit
%
150
6.47
5.5
±0.2
20
26
26
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
14
375V Micro Family
Page 4 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
375V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 50W (e.g. S375C5C50BL, V375C5C50BL)
Parameter
Efficiency
S375C5C50BL (enhanced efficiency)
V375C5C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
79.5
6.03
Typ
85.0
80.9
120
6.25
2.7
±0.02
11.5
11.5
Max
Unit
%
150
6.47
3.4
±0.2
10
13.5
13.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
7
8V
OUT
, 100W (e.g. S375C8C100BL, V375C8C100BL)
Parameter
Efficiency
S375C8C100BL (enhanced efficiency)
V375C8C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
82.5
9.36
Typ
87.0
83.7
180
9.7
3.6
±0.02
14.4
14.4
Max
Unit
%
225
10.1
4.2
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 150W (e.g. S375C12C150BL, V375C12C150BL)
Parameter
Efficiency
S375C12C150BL (enhanced efficiency)
V375C12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
85.0
13.7
Typ
86.0
86.0
220
14.3
5.4
±0.02
14.4
14.4
Max
Unit
%
275
14.9
7.4
±0.2
12.5
16.9
17.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 75W (e.g. S375C12C75BL, V375C12C75BL)
Parameter
Efficiency
S375C12C75BL (enhanced efficiency)
V375C12C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
84.0
13.7
Typ
88.0
85.5
100
14.3
3.5
±0.02
7.19
7.19
Max
Unit
%
125
14.9
4
±0.2
6.25
8.44
8.44
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Repost: From [url]www.hellodsp.com[/url], some comparisons between 2407 and 2812. Last night, a friend who just learned DSP asked me whether there was a big difference between 2407 and 2812. I could o...
Our company is planning to make a lithium battery capacity cabinet recently. Has anyone done this before? If anyone has, I hope they can share some information....
I want to add a power measurement function to my work. It doesn't need to be very accurate.Can I use a power measurement IC with external peripherals or can the MSP430 itself easily achieve this funct...
bib file is modified as follows, is it correct? MODULES ; Name Path Memory Type ; ScanDLL.dll $(_FLATRELEASEDIR)\ScanDLL.dll NK SH After the dll file is generated, which directory will it be placed in...
Iar for map430 compiler software selects the highest level in C-optimizations setting, compiles successfully, and the program runs normally, but any change in global.h, even a space, will cause deviat...
Sailing is gaining more and more attention. How to use modern technology to assist training and improve competition results is particularly important. Considering the real-time data collection in t...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
In recent years, with the increasing maturity of LED technology, LED light sources have been increasingly widely used due to their advantages of using low-voltage power supply, low energy consumpti...[Details]
1. Project Introduction
Beijing Benz-Daimler Chrysler Co., Ltd. is a joint venture between Beijing BAIC Group and Benz-Daimler Chrysler. In October 2005, it started to build a new automobile ...[Details]
1. Introduction
Stepper motor is a basic component that converts electrical energy into kinetic energy. It has been widely used in a variety of electromechanical equipment, such as various machine...[Details]
The battery and its management system are one of the key technologies of electric vehicles. In the past few years, most companies have encountered embarrassment in the development of electric vehic...[Details]
The cruise control system (CCS) of a vehicle is also called a constant speed driving system. It is an electronic control device that uses advanced electronic technology to automatically adjust the ...[Details]
1 Theoretical Analysis
Ultrasonic waves
When propagating in a suspension, the ultrasonic waves that encounter the suspended particles are scattered and attenuated at the interface, an...[Details]
Introduction
Every year, cars are equipped with more complex electronic systems to maximize comfort, safety, and performance while minimizing harmful emissions. According to market resea...[Details]
As the electromagnetic environment in space becomes increasingly complex, the shielded cables used to transmit weak signals in the test system are easily affected by external electromagnetic distur...[Details]
This paper mainly studies the parallel current sharing technology of Droop method DC/DC converters, and designs a current sharing converter with parallel output of two DC/DC converters based ...[Details]
1 Introduction
At present, with the growing calls for environmental protection and energy conservation, new types of transportation that are pollution-free and have diversified energy configur...[Details]
In a network-centric battlefield, all systems (platforms) are interconnected nodes that work together to provide mission-critical information to military personnel. This approach is driving the dev...[Details]