ERL05422K00FKEK500

Description
Fixed Resistor,
CategoryPassive components    The resistor   
File Size138KB,4 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance
Download Datasheet Parametric View All

ERL05422K00FKEK500 Overview

Fixed Resistor,

ERL05422K00FKEK500 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7271683708
Reach Compliance Codeunknown
ECCN codeEAR99
YTEOL6.45
structureTubular
Lead diameter0.41 mm
Lead length31.75 mm
Installation featuresTHROUGH HOLE MOUNT
Number of terminals2
Maximum operating temperature150 °C
Minimum operating temperature-65 °C
Package diameter1.68 mm
Package length3.81 mm
Package formAxial
method of packingBULK
Rated power dissipation(P)0.125 W
Rated temperature70 °C
resistance422000 Ω
Resistor typeFIXED RESISTOR
surface mountNO
technologyMETAL FILM
Temperature Coefficient100 ppm/°C
Terminal shapeWIRE
Tolerance1%
Operating Voltage200 V
ERL Industrial
www.vishay.com
Vishay Dale
Metal Film Resistors, Industrial / High Reliability
FEATURES
• Same materials and construction as the
MIL-PRF-39017 resistors
• 100 % stabilization and screening tests.
Undergoes group A testing to MIL-PRF-39017
(power conditioning, short time overload,
DC resistance) prior to shipping.
• Epoxy coated construction provides superior
moisture protection
• Traceability of materials and processing
• Very low noise (-40 dB)
• Vishay Dale has complete capability to develop specific
reliability programs designed to customer requirements
• Material categorization: for definitions of compliance
please see
www.vishay.com/doc?99912
STANDARD ELECTRICAL SPECIFICATIONS
GLOBAL MODEL
POWER RATING
P
70 °C
W
0.125
MAXIMUM WORKING
VOLTAGE
(1)
V
200
RESISTANCE
RANGE
4.7 to 1M
1.1M to 22M
1 to 10M
11M to 22M
4.3 to 3.01M
3.3M to 22M
1 to 2.7M
3M to 22M
10 to 2.7M
3M to 22M
TOLERANCE
±%
1, 2
2, 5, 10
1, 2
2, 5, 10
1, 2
2, 5, 10
1, 2
2, 5, 10
1, 2, 5, 10
1, 2, 5, 10
TEMPERATURE
COEFFICIENT
± ppm/°C
100
200
100
200
100
200
100
200
100
200
ERL05..500
ERL07..500
0.25
250
ERL20..500
0.5
350
ERL32..500
1.0
500
ERL62..500
2.0
500
Note
(1)
Continuous working voltage shall be
P
x
R
or maximum working voltage, whichever is less.
TECHNICAL SPECIFICATIONS
PARAMETER
Voltage Coefficient, max.
Dielectric Strength
Insulations Resistance
Operating Temperature Range
Terminal Strength
Solderability
Weight
g
UNIT
ppm/V
V
AC
°C
lb
CONDITION
5/V when measured between 10 % and full rated voltage
ERL05-500 = 300; ERL07-500 and ERL20-500 = 500; ERL32-500 = 1000; ERL62-500 = 900
10
9
min. dry;
10
11
min. after moisture test
-65 to +150
2 lb pull test on ERL05-500; 5 lb pull test on all other sizes
Continuous satisfactory coverage when tested in accordance with MIL-STD-202, method 208
ERL05-500 = 0.11; ERL07-500 = 0.35; ERL20-500 = 0.75; ERL32-500 = 1.05; ERL62-500 = 1.30
Revision: 15-Mar-16
Document Number: 31105
1
For technical questions, contact:
ff2aresistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Beaglebone black finally arrived
[b]Beaglebone black has finally arrived. Move it, move it! [/b]...
7leaves DSP and ARM Processors
In WINCE, where are the file allocation table (FAT table) and file directory table (FDT table) of the FAT32 file system of NAND FLASH located in NAND FLASH? Or is it not necessary?
In WINCE, where are the file allocation table (FAT table) and file directory table (FDT table) of the FAT32 file system of NAND FLASH located in NAND FLASH? Or is it not necessary?...
renrongwen Embedded System
Iar compilation
The iar project provided by the customer has a configuration similar to that of a general iar project, but there is one difference as shown in the following figureHowever, a problem will occur when co...
蓦然回首qbb stm32/stm8
XJ4241 Oscilloscope Schematic Diagram
XJ4241 Oscilloscope Schematic Diagram...
shamoxue DIY/Open Source Hardware
What is the difference between a failed start and a failed start?
There are start failure and failure start pressure plates on the generator-transformer protection cabinet. What is the difference between these two pressure plates? How to understand?...
jek9528 Industrial Control Electronics
Sensortag issues
I use smart RF as the host and burn the SimpleBLECentral program in it. Sensortag is used as the slave and burns the sensortag in the protocol stack. The Bluetooth cannot establish a connection. I bur...
xuanyi Wireless Connectivity

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 498  950  2296  692  541  11  20  47  14  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号