Rocker Switch, (on)-off-(on), Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2647LHAB17/101L110V Overview

Rocker Switch, (on)-off-(on), Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2647LHAB17/101L110V Parametric

Parameter NameAttribute value
Objectid313035118
Reach Compliance Codecompliant
Country Of OriginUK
ECCN codeEAR99
YTEOL8.89
Actuator colorWHITE
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact function(ON)-OFF-(ON)
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
illuminationLAMP
Insulation resistance1000000000 Ω
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch actionMOMENTARY
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Is it true that positioning can be done through mobile phones?
The website is this: http://gps.ipl38.com/user/?433345-1.html. I tried it and it seems inaccurate. But I am not a registered user. Has anyone used it?...
zhangjun16 Talking
Ethernet Applications on MCU
Ethernet Applications on MCU...
lorant MCU
How to extract the digits of an integer
I would like to ask you how to extract the digits of a six-digit integer and put them into an array. For example, for the six-digit number 246358, we need to put the digits 2, 4, 6, 3, 5, 8 into the a...
33love Microcontroller MCU
Super cool AVR library functions, header files and usage examples provided by GNU official
[size=2]This file contains many commonly used peripheral applications, even vs1003 GPS, etc. I really admire this open source spirit. This site wants to organize the library functions under ICC [b] AV...
呱呱 Microchip MCU
[Construction Monitoring and Security System] 5. lv_port_esp32 project integrates Kaluga components
This article is about some of my experiences in studying IDF in recent days, and the content will be relatively scattered. 1. Preliminary attempt to add components to lv_port_esp32 In the previous rev...
sonicfirr DigiKey Technology Zone
Find Herun's amplifier IC
Find Herun's amplifier IC: HT317,...
Fred_1977 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1757  708  17  1736  774  36  15  1  35  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号