DB101G
THRU
DB107G
Single Phase 1.0 AMP. Glass Passivated Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
1.0 Ampere
Features
a
a
a
a
a
a
a
UL Recognized File # E-96005
Ideal for printed circuit board
Reliable low cost construction utilizing
molded plastic technique
High temperature soldering guaranteed:
250°C / 10 seconds / 0.375” ( 9.5mm )
lead length at 5 lbs., ( 2.3 kg ) tension
Small size, simple installation
Leads solderable per MIL-STD-202,
Method 208
High surge current capability
DB
DBS
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
@T
A
= 40°C
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated Load
(JEDEC method )
Maximum Instantaneous Forward Voltage
@ 1.0A
Maximum DC Reverse Current @ T
A
=25°C
at Rated DC Blocking Voltage @ T
A
=125°C
Operating Temperature Range T
J
Storage Temperature Range T
STG
DB101G DB102G DB103G DB104G DB105G DB106G DB107G
DBS
DBS
DBS
DBS
DBS
DBS
DBS
101G
102G
103G
104G
105G
106G
107G
50
35
50
100
70
100
200
140
200
400
280
400
1.0
50
1.1
600
420
600
800
560
800
Units
1000
V
700
V
1000
V
A
A
V
uA
uA
°C
°C
10
500
-55 to +150
-55 to +150
Note: DBS for Surface Mount Package.
- 470 -
RATINGS AND CHARACTERISTIC CURVES (DB101G THRU DB107G)
FIG.1- MAXIMUM DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
60
.06" (1.5mm)
PCB
Copper Pauls
.51" x .51"
(13mm x 13mm)
1.0
FIG.2- MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT
PEAK FORWARD SURGE CURRENT. (A)
Tj=25
0
C
Single Sine - Wave
(JEDEC Method)
AVERAGE FORWARD CURRENT. (A)
50
40
30
20
10
0
0.5
60Hz RESISTIVE OR
INDUCTIVE LOAD
0
20
40
60
80
o
100
120
140
150
1
2
4
6
10
20
40
60
100
AMBIENT TEMPERATURE. ( C)
NUMBER OF CYCLES AT 60Hz
FIG.3- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
100
FIG.4- TYPICAL FORWARD CHARACTERISTICS
PER BRIDGE ELEMENT
10
Tj=125
0
C
INSTANTANEOUS REVERSE CURRENT. ( A)
10
INSTANTANEOUS FORWARD CURRENT. (A)
1
1.0
0.1
.10
Tj=25
0
C
Tj=25 C
PULSE WIDTH-300 S
2% DUTY CYCLE
.01
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
140
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0
FORWARD VOLTAGE. (V)
100
FIG.5- TYPICAL JUNCTION CAPACITANCE PER
BRIDGE ELEMENT
CAPACITANCE.(pF)
10
Tj=25
0
C
f=1.0MHz
Vsig=50mVp-p
1
1.0
10
REVERSE VOLTAGE. (V)
100
- 471-