All specifications are based on 25°C, Nominal Input Voltage (115V and 230V), <75% Humidity and Rated Output Load unless otherwise noted.
We reserve the right to change specifications based on technological advances.
GENERAL SPECIFICATIONS
Efficiency
Isolation Voltage
Switching Frequency
PHYSICAL SPECIFICATIONS
Weight
Dimensions (L x W x H)
Cooling
SAFETY CHARACTERISTICS
Safety Standards & Certifications
Safety Class
EMI
ESD
RS
EFT
Surge
CS
Voltage Dips, Short Interruptions and
Voltage Variations Immunity
TEST CONDITIONS
Input-Output, 1 minute Test Time
Min
3000
Typ
Max
Unit
VAC
kHz
See Table
65
0.21oz (6g)
1.38in x 0.65in x 0.43in
(35mm x 16.45mm x 11mm)
1.38in x 0.71in x 0.43in
(35mm x 18mm x 11mm)
Free Convection
SIP Model
SIP Model with 90º Bend
CE
RE
IEC/EN61000-4-2
IEC/EN61000-4-3
IEC/EN61000-4-4
IEC/EN61000-4-4
IEC/EN61000-4-5
IEC/EN61000-4-5
IEC/EN61000-4-6
IEC/EN61000-4-11
IEC60950, EN60950, UL60950
(11)
Class II
(4)
CISPR32/EN55032
CISPR32/EN55032
(5)
CISPR32/EN55032
(4)
CISPR32/EN55032
(5)
±4kV
10V/m
(5)
±2kV
(4)
±4kV
(5)
Line to line ±1kV
(4)
Line to line ±1kV/line to ground ±2kV
(5)
10Vr.m.s
(5)
0%, 70%
(5)
Class A
Class B
Class A
Class B
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
Add -F to model name to indicate 90º corner model.
When 3.3V/5V/9V/12V models are working in -20-40ºC temperature range output filter capacitor C2 needs 270µF/16V solid-state capacitor.
Ripple & Noise are measured by “parallel cable” method.
See Fig. 1 for typical application circuit.
See Fig. 2 for recommended circuit.
External electrolytic capacitors are required to use modules.
This part is open frame, at least 6.4mm safety distance between the primary and secondary external components of the module is needed to meet
safety requirement.
8. In order to increase the conversion efficiency of the product with light load in the design, the product will have audio noise when it is operating, but
it will not affect the product’s reliability and performance.
9. Module requires dispensing fixed after assembly.
10. Product customization available.
11. This product is Listed to applicable standards and requirements by UL.
*Due
to advances in technology, specifications subject to change without notice.