EEWORLDEEWORLDEEWORLD

Part Number

Search

3100-30T10999CJ

Description
3100-30T10999CJ=40A CONTACTOR
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size75KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance  
Download Datasheet Parametric View All

3100-30T10999CJ Online Shopping

Suppliers Part Number Price MOQ In stock  
3100-30T10999CJ - - View Buy Now

3100-30T10999CJ Overview

3100-30T10999CJ=40A CONTACTOR

3100-30T10999CJ Parametric

Parameter NameAttribute value
Terminal configurationquick connect, box lugs
Contactor typededicated
model98
Product CategoryElectromechanical relay
Product CategoriesRelay - Contactor
curved coverwith
moldedno
Auxiliary switch terminal arrangementWithout
Coil voltage (max) (VAC)120
Coil Voltage Rating (VAC)120
Coil resistance (Ω)180
Terminal switching voltage (max) (VAC)600
Drive Systemcomminicate
Terminal base materialsilver cadmium oxide
Electrode configuration3
Terminal Current Rating (A)40
Terminal arrangement3 Form X,3PST-NO-DM
Coil Termination6-32 screw, quick connect
Installation typepanel
mounting platewith
Wire size (mm²)2.08 – 21.2
Wire size (AWG)14 – 4
UL flammability ratingUL 94V-0
Institutional ApprovalObtained CSA certification, Obtained SEMKO certification, Obtained UL certification
Encapsulation methodliving block
Torque (in-lbs)40
Catalog 1308242
Issued 3-03 (PDF Rev. 3-04)
PRODUCTS UNLIMITED
Model 98 - 3100
series
Definite Purpose Contactor
3-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 3-pole contactors.
• Industry-standard mounting plate.
• Optional interlock/auxiliary switches available.
• Manual test button is standard.
• Coil dust cover helps keep dust and dirt away from magnet and coil area.
• Double E magnet system provides optimal performance.
Environmental Data
Temperature Range:
Storage and Operating: -40°C – +65°C.
Flammability:
UL 94-HB housing.
Mechanical Data
Contact Data @ 25°C
Arrangements:
3 Form X (3PST-NO-DM).
Maximum Ratings:
See Contact Ratings Table.
Material:
Silver Cadmium Oxide.
Contact Termination:
20, 25, 30 FLA Models
Type:
#10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size:
16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque:
25 in.-lbs.
40 FLA Models
Type:
Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size:
14-4 Cu/Al AWG
Tightening Torque:
40 in.-lbs.
Coil Termination:
Dual 0.250” (6.35 mm) quick connects, standard.
A 0.250” quick connect and a #6-32 screw, optional.
Arc Cover:
Optional on 20-30 FLA models, standard on 40 FLA models.
Weight:
16 oz. (455 g) approximately
Coil Data @ 25°C
Voltage:
24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Ratings
Full
Load
Amps
20
Number
of
Poles
3
Line
Voltage
240/277
480
600
240/277
480
600
Locked
Rotor
Amps
120
100
80
150
125
100
Resistive
Amps
Rating
30
30
30
35
35
35
Voltage
110/120
200/240
480/600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
Maximum Horsepower
Single
Phase
1.5
3
-
2
-
5
-
-
2
-
5
-
-
3
-
7.5
-
-
Three
Phase
-
7.5
7.5
-
7.5
10
15
20
-
10
10
15
20
-
10
10
20
25
25
3
30
3
240/277
480
600
180
150
120
40
40
40
40
3
240/277
480
600
240
200
160
50
50
50
Coil Data
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
24
18
6 -15
60
53
6.0
5
7
120
88
20 - 70
60
53
6.0
5
180
208/240
177
40 - 140
60
53
6.0
5
720
277
220
65 - 185
60
53
6.0
5
950
480
384
150 - 270
65
53
6.0
5
3100
Dimensions are shown for
832
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
How to enable SAM D21 interrupt?
The program compiled by atmel's library is relatively large, so I wrote my own driver now, using SERCOM3 as I2C, and enabled the interrupt enable set register, but why can't I enter the SERCOM3_Handle...
289811230 Microchip MCU
Tumbler remote control
The remote control is very easy to "lose". Although in most cases it is "lost but not lost" and can be found, it still takes a lot of trouble. Since it is difficult to find it when you are short, let ...
xyh_521 Creative Market
MCU Simulation Example
There are many examples in it, which are often used by undergraduate students....
wsh5106 MCU
Electronics use applet collection
[i=s] This post was last edited by paulhyde on 2014-9-15 03:04 [/i] Please refer to it when you want to use it....
非雪之悠 Electronics Design Contest
Help on MCS-51 microcontroller
The following is the digital clock program for the MCS-51 microcontroller. I would like to ask for help! Please help me with the question #include "reg51.h" unsigned char code disptab[] = {0xC0,0xF9,0...
348770408 51mcu
Debugging help for power chip mc34063
I have been adjusting mc34063 for a day today. The input voltage is 9V. I originally planned to reverse output -8V voltage, but there was a problem with the output, so I changed it to a step-down outp...
200445184 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 797  170  891  866  1889  17  4  18  39  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号