VERSAFIT-1/8-2-SP Overview

VERSAFIT-1/8-2-SP

VERSAFIT-1/8-2-SP Parametric

Parameter NameAttribute value
Wall typesingle
Product SeriesVERSAFIT
Voltage (max) (kV).6
colorred
Shrinkage2:1
MaterialIrradiated modified polyolefin
flexibilityVery flexible
Fluid typeChemicals/Solvents, Water, Lubricants, Hydraulic Fluids, Aviation Fuels, Defrosters
Expand inner diameter (minimum value)3.23 mm [ .128 in ]
Recovered inner diameter (maximum value)1.57 mm [ .062 in ]
Recovered wall thickness (nominal).51 mm [ .02 in ]
Recovered wall thickness (tolerance).16 mm [ .006 in ]
Shrinkage temperature (min) (°C)70
Resistanttension, liquid, wrinkle
Operating temperature range (°C)-55 – 135
FlammabilityHigh flame retardancy
Shrinkage temperature (°C)90
fluid resistancesplash proof
Applicable areaglobal, global
Encapsulation methodspool
Product sourceUS
Low outgassingno
Versafit
Highly flame-retardant, low recovery
temperature, heat-shrinkable tubing
Versafit heat-shrinkable tubing is a
cost-effective choice for many
commercial and military applications.
Versafit tubing is made from a
specially formulated, crosslinked
polyolefin to provide high flame-
retardance (VW-1), excellent flexibility,
and a low shrink temperature (to
reduce installation time).
Versafit tubing performs a variety
of functions in commercial and
military applications:
Temperature rating
Full recovery temperature:
Continuous operating temperature:
90°C
–55°C to 135°C
®
PBBs
PBBEs
PBBOs
s
s
s
Electrically insulates and protects
in-line components, disconnect
terminals, and splices.
Bundles wires for very flexible
light-duty harnesses.
Identifies or color-codes wires,
cables, terminals, and components.
Versafit tubing hot-stamps
extremely well.
thermal stability and resistance to
physical abuse.
Unlike other typical flame-retardant
tubings, Versafit tubing is free of
polybrominated biphenyls (PBBs) and
polybrominated biphenyl oxides and
ethers (PBBOs/PBBEs). In Europe,
these chemicals are classified as
environmentally hazardous
substances.
Compared to noncrosslinked
materials, Versafit tubing has a higher
temperature rating and exhibits better
Specifications*
Type
Versafit
Raychem
RW-3009
UL
E35586 VW-1
600V, 125°C
CSA
LR31929 VW-1
600V, 125°C
Military
AMS-DTL-23053/5
Classes 1 and 3
*
When ordering, always specify latest issue.
Dimensions (millimeters/inches)
W
Expanded as supplied
D
Fully recovered after heating
d
Size
3/64
1/16
3/32
1/8
3/16
1/4
3/8
1/2
5/8
3/4
1
1 1/4
1 1/2
2
3
4
Inside diameter
D
Expanded as supplied
1.63 ± 0.2
0.064 ± 0.008
1.85 ± 0.2
0.073 ± 0.007
2.79 ± 0.2
0.110 ± 0.007
3.43 ± 0.2
0.135 ± 0.007
5.21 ± 0.3
0.205 ± 0.010
7.11 ± 0.3
0.280 ± 0.010
10.16 ± 0.4
0.400 ± 0.015
13.72 ± 0.4
0.540 ± 0.015
16.90 ± 0.4
0.665 ± 0.015
20.45 ± 0.4
0.805 ± 0.015
25.53 ± 0.4
1.055 ± 0.015
33.40 ± 0.7
1.315 ± 0.025
39.88 ± 0.8
1.570 ± 0.030
52.83 ± 1.0
2.080 ± 0.040
78.49 ± 1.0
3.090 ± 0.040
104.14 ± 1.3
4.100 ± 0.050
d (max.)
Recovered after heating
0.6
0.023
0.8
0.031
1.2
0.046
1.6
0.062
2.4
0.093
3.2
0.125
4.8
0.187
6.4
0.250
8.0
0.315
9.5
0.375
12.7
0.500
15.9
0.625
19.1
0.750
25.4
1.000
38.1
1.500
50.8
2.000
Wall thickness
W
Recovered after heating**
0.40 ± 0.08
0.016 ± 0.003
0.43 ± 0.08
0.017 ± 0.003
0.51 ± 0.08
0.020 ± 0.003
0.51 ± 0.08
0.020 ± 0.003
0.51 ± 0.08
0.020 ± 0.003
0.64 ± 0.08
0.025 ± 0.003
0.64 ± 0.08
0.025 ± 0.003
0.64 ± 0.08
0.025 ± 0.003
0.76 ± 0.08
0.030 ± 0.003
0.76 ± 0.08
0.030 ± 0.003
0.89 ± 0.13
0.035 ± 0.005
1.02 ± 0.15
0.040± 0.006
1.02 ± 0.15
0.040 ± 0.006
1.14 ± 0.16
0.045 ± 0.007
1.27 ± 0.20
0.050 ± 0.008
1.40 ± 0.23
0.055 ± 0.009
**Wall thickness will be less if tubing recovery is restricted during shrinkage.
Ordering information
Colors
Size selection
Standard packaging
Ordering description
Standard
Black, white, red, blue, yellow and green
Nonstandard
Brown, orange, violet, and gray
Always order the largest size that will shrink snugly over the component being covered.
A variety of special order sizes are available.
On spools.
Specify product name, size, and color; for example, Versafit 1/4-0 (0=Black).
Hello everyone!! I have a question for VHDL experts!!!
Hello everyone!! I have a question for VHDL experts!!! The problem is mainly with the following statement: --#20100403# Question: I don't know what's going on? If the following three statements are no...
randy67 FPGA/CPLD
Urgent help, about the USART serial communication (sp3232) problem of STM32F407VGT6 chip (please help if you pass by)
Today I would like to ask you a question about the serial port communication of STM32F407 . Actually, this is a very basic question, but I have to ask you.1. Problem descriptionThe microcontroller use...
annysky2012 stm32/stm8
Computer Simulation of High Frequency Electronic Circuits
I recently did two computer simulations of high-frequency electronic circuits... an AM receiver and an FM transmitter... They are very crude... I welcome your comments and suggestions......
open82977352 Talking
Gesture remote control
Gesture remote control Author: brother0952Project BackgroundToday's smart homes are developing very rapidly, and the ways to control home appliances are diverse, from the initial mechanical buttons, t...
brother0952 ST MEMS Sensor Creative Design Competition
How to properly place the inductor on the power supply PCB? You will understand it in seconds after reading this article!
[i=s]This post was last edited by ohahaha on 2019-6-3 11:25[/i] [font=微软雅黑][size=4] [/size][/font][align=center][b][font=微软雅黑][size=4]First, we ask the question: where should the coil be placed? [/siz...
ohahaha Energy Infrastructure?
When developing in MDK, how do I select the include parths in the Add TivaWare Hooks step? What is it used for?
When developing in MDK, how do I select the include parths in the Add TivaWare Hooks step? What is it used for?...
小海93 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1141  1549  1102  2342  1166  23  32  48  24  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号