EEWORLDEEWORLDEEWORLD

Part Number

Search

A48125G-10

Description
Solid State Relay
CategoryLED optoelectronic/LED    photoelectric   
File Size183KB,3 Pages
ManufacturerCrydom
Websitehttp://www.crydom.com/en/index.shtml
Download Datasheet Parametric View All

A48125G-10 Overview

Solid State Relay

A48125G-10 Parametric

Parameter NameAttribute value
Objectid107843866
Reach Compliance Codecompliant
YTEOL0
Series
1-110/125A
120/240, 480 Vac - AC OUTPUT
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• Internal Snubber
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and ver-
sions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
A24125
D24125
HA48110
HD48110
HA48125
HD48125
MODEL NUMBERS
OUTPUT SPECIFICATIONS
1
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
AC CONTROL
DC CONTROL
A24110
D24110
24-280
110
150
600
1500
1.7
.25
9,340
10
500
24-280
125
150
600
1750
1.7
.22
12,700
10
500
48-530
110
150
1200
1500
1.7
.25
9,340
10
500
48-530
125
150
1200
1750
1.7
.22
12,700
10
500
3
[Arms]
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
qJC
) [°C/W]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
2
4
0.5
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec (AC Control)
0.5
0.5
0.5
INPUT SPECIFICATIONS
1
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
DC CONTROL
(D PREFIX)
AC CONTROL
(A PREFIX)
24V AC/DC CONTROL
(E SUFFIX)
3-32 Vdc
-32 Vdc
3.0 Vdc
1.0 Vdc
1500 Ohms (120/240V Models)
5
3.4mA @ 5 Vdc, 20mA @ 28Vdc
5
90-280 Vrms (60Hz)
---
90 Vrms
10 Vrms
60K Ohms
2mA @ 120 Vrms, 4mA @ 240 Vrms
18-36 Vrms/Vdc
---
18 Vrms/Vdc
4.0 Vrms/Vdc
9.0K Ohms
3mA @ 24 V
GENERAL NOTES
© 2007 CRYDOM Inc., Specifications subject to change without notice.
1
All parameters at 25°C unless otherwise specified.
2
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3
Heat sinking required, for derating curves see page 2.
4
Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
5
Input circuitry for 480V models incorporates active current limiter with 2mA typical input current..
For recommended applications and more information contact:
USA:
Sales Support (877) 502-5500
Tech Support
(877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 606030 •
FAX
+44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506
Series 1-110/125.
Rev. 052307
PAGE 1 OF 2
Welcome hongyang to join the embedded management team~~~
:victory: I look forward to working with the embedded moderator to make the embedded section better and better....
soso Embedded System
C2000 Essential for Getting Started
[b]1. I often see netizens posting questions about getting started with DSP. Here we summarize the C2000 entry questions: [/b][align=left][color=#000](1) When consulting about getting started with C20...
灞波儿奔 Microcontroller MCU
Failed to download the program to the target machine in evc?
I used to use EVC+Microsoft ActiveSync to download programs to the target machine for execution, but since I bought a new computer, during the installation of EVC, the system prompted: "The installed ...
后学 Embedded System
Add FIQ processing function to ucos
I am using the ucos code provided by mini2440. I want to add a FIQ handler to ucos. I made some changes in 2440init.s. The jump of FIQ in the exception vector table is changed to b FIQ_HANDLE Jump to ...
filmwind Real-time operating system RTOS
Help! Urgently looking for the layout of UA741
I need the layout of UA741 urgently. Can anyone help me?...
bily508 PCB Design
C8051 welding problems
I took the time to solder all the components, but there are still a few small regrets. 1. There is no 10K resistor in the distributed components, so this one is not soldered. I will look for it tomorr...
kaixinlaohe DIY/Open Source Hardware

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2875  2675  1684  1587  712  58  54  34  32  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号