Part Number

Search

34ADP22B9M2RT

Description
Toggle Switch, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size979KB,6 Pages
ManufacturerGrayhill
Websitehttp://www.grayhill.com
Environmental Compliance
Download Datasheet Parametric View All

34ADP22B9M2RT Overview

Toggle Switch, ROHS COMPLIANT

34ADP22B9M2RT Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7002683118
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Executor completedCHROME
Actuator length0.2 inch
Actuator materialBRASS
Actuator typeTOGGLE
Other featuresUL
body width0.45 mm
body height0.41 mm
Body length or diameter0.5 mm
Casing diameter0.465 inch
Nozzle length0.296 inch
Casing type1/4-40
center contact materialCOPPER ALLOY
Center contact platingGOLD
Contact (AC) maximum rated R load5A@125VAC
Maximum contact current (AC)5 A
Maximum contact current (DC)5 A
Contact (DC) maximum rated R load5A@28VDC
Contact functionON-(ON)
Contact resistance0.01 mΩ
contact timeMAKE-BEFORE-BREAK
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)28 V
Dielectric withstand voltage1000VRMS V
Electrical life40000 Cycle(s)
End contact materialCOPPER ALLOY
End contact platingGOLD
Shell materialSTAINLESS STEEL
Insulation resistance1000000000 Ω
insulator materialDIALLYL PHTHALATE
Installation featuresTHROUGH HOLE-STRAIGHT
Maximum operating temperature85 °C
Minimum operating temperature-30 °C
sealEPOXY TERMINAL SEALED
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typeTOGGLE SWITCH
Terminal length0.25 inch
Termination typeSOLDER
Series 34A: Miniature Toggle Switches
Miniature Toggle Switches
FEATURES
• Save Space and Weight
• SPDT, DPDT, 3PDT, and 4DPT Circuitry
• Choice of Actuators, Bushings and Terminations
• UL Recognized
MODELS
SPDT
MODEL NO.
SP1
SP2
SP3
SP4
SP5
TERM. COMM.
SERIES 34A
in inches (and millimeters)
.570
(14.48)
SWITCH POSITION
ON
NONE
ON
NONE
ON
OFF
OFF
(ON)
OFF
ON
2-3,5-6
OPEN
8-9
Toggle Switches
KEYWAY
ON
(ON)
ON
(ON)
(ON)
2-1,5-4
8-7
.415
(10.54)
.030
(0.76)
KEYWAY
THIS SIDE
9
6
3
.500
(12.7)
.650
(16.51)
1/4-40 UNS-2A
.350
(8.89)
.410
(10.41)
.185
(4.70)
EPOXY SEAL
.060
(1.52)
.190
(4.83)
8
5
2
7
4
1
()=MOMENTARY
02COMM.
05COMM.
08COMM.
Ø.115
(Ø 2.92)
1
3
SCHEMATIC
4
6
7
9
DPDT
MODEL NO.
DP1
DP2
DP3
DP4
DP5
TERM. COMM.
SWITCH POSITION
NONE
ON
NONE
ON
OFF
ON
OFF
(ON)
OFF
ON
2-3,
OPEN
5-6
05COMM.
KEYWAY
ON
(ON)
ON
(ON)
(ON)
2-1,
5-4
.350
(8.89)
.410
(10.41)
.505
(12.83)
.060
(1.52)
KEYWAY
THIS SIDE
6
5
4
3
2
1
.190
(4.83)
.500
(12.7)
.450
(11.43)
1/4-40 UNS-2A
Ø.115
(Ø 2.92)
.185
(4.70)
()=MOMENTARY
02COMM.
.350
(8.89)
1
3 4
SCHEMATIC
6
.030
(0.76)
EPOXY SEAL
3PDT
MODEL NO.
SP1
SP2
SP3
SP4
SP5
TERM. COMM.
.570
(14.48)
SWITCH POSITION
ON
NONE
ON
NONE
ON
OFF
OFF
(ON)
OFF
ON
2-3,5-6
OPEN
8-9
KEYWAY
ON
(ON)
ON
(ON)
(ON)
2-1,5-4
8-7
.415
(10.54)
.030
(0.76)
KEYWAY
THIS SIDE
9
6
3
.500
(12.7)
.650
(16.51)
1/4-40 UNS-2A
.350
(8.89)
.410
(10.41)
.185
(4.70)
EPOXY SEAL
.060
(1.52)
.190
(4.83)
8
5
2
7
4
1
()=MOMENTARY
02COMM.
05COMM.
08COMM.
Ø.115
(Ø 2.92)
1
3 4
SCHEMATIC
6 7
9
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
【Uncle T's Library】Generation, measurement and suppression of switching power supply ripple
Contents: 1. Switching power supply ripple generation 2. Switching power supply ripple test 3. Switching power supply ripple suppression 4. Summary...
wzt Power technology
What do these VHDL warnings mean (running in Quartus)?
LIBRARY IEEE; USE IEEE.STD_LOGIC_1164.ALL; ENTITY not1 IS PORT(a : IN STD_LOGIC; b : OUT STD_LOGIC); END not1; ARCHITECTURE no_t OF not1 IS BEGIN b <= NOT a; END no_t; I just learned VHDL and programm...
wwz04 Embedded System
systick_config() function debugging problem
[table=98%,rgb(222, 240, 251)] [tr][td] [/td][/tr] [/table]When the author used Keil5 to debug the systick_config() function [the chip used was GD32F450Z], the debugging would enter HardFault_Handler ...
明明很爱你 GD32 MCU
A brief discussion on the four combinations of security engineering
[align=left]Abstract: Starting from the comparison of domestic and foreign security projects, this paper analyzes the "four combinations" proposed by Professor Xu Tanlin for security projects, and poi...
maker Industrial Control Electronics
How to assign a separate segment to the bss of a C file in the link file?
I want to put the bbs of a C file in a separate segment. In this way, when the program is running, all the RAM in this segment will be cleared to restore a module to its initial state. The compiler I ...
woody_chen Programming Basics
stm32 generates 3 PWM channels, each with the same duty cycle and a phase difference of 120 degrees.
Can a timer be used to control a brushless DC motor?...
1208193886 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2840  479  1909  2876  605  58  10  39  13  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号