EEWORLDEEWORLDEEWORLD

Part Number

Search

LCS012T19PD22AY

Description
SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 9.95mm, THROUGH HOLE-STRAIGHT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size326KB,4 Pages
ManufacturerC&K Components
Environmental Compliance  
Download Datasheet Parametric View All

LCS012T19PD22AY Overview

SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 9.95mm, THROUGH HOLE-STRAIGHT, ROHS COMPLIANT

LCS012T19PD22AY Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1084500325
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Country Of OriginMainland China
ECCN codeEAR99
YTEOL7.7
Actuator stroke9.95 mm
Actuator typeLEVER
body width6.4 mm
body height9.8 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load.1A@250VAC
Maximum contact current (AC)0.1 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Installation featuresTHROUGH HOLE-STRAIGHT
Maximum operating force1.99 N
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Maximum pre-travel8 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSOLDER
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 250 V AC and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE:
-40ºC to +120ºC (without wire)
-40ºC to +85ºC (with UL1007 wire)
-40ºC to +105ºC (with UL1015 wire)
-40ºC to +105ºC (with UL1430 wire)
-40ºC to +80ºC (with UL1061 wire)
-40ºC to +120ºC (with UL1330 wire)
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
11.9 mm short lever
T05
17.4 mm short lever
T07
19.4 mm short lever
T13
25.5 mm lever
T19
33.3 mm lever
T28
40.7 mm lever
T43
55.9 mm lever
S26
18.6 mm simulated lever
A05
17.2 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
How to verify whether FLASH is working properly? How to detect if ID cannot be detected?
It's like this D~ After making several boards, one of them is running. JTAG can detect CPU. Can detect NORFLASH NANDFLASH ID. Can download BOOTLOADER to NORFLASH NANDFLASH and copy from FLASH to SDRAM...
精灵小妹 Embedded System
Request for the establishment of a smart agriculture section
Why doesn't our forum have a section on smart agriculture? I hope the administrator can set up such a section so that everyone can communicate together!...
wateras1 Suggestions & Announcements
A LiDAR Level Meter Silo Level Measurement Solution
Measurement solution: The laser radar is installed in the middle of the silo top and is aimed vertically downward at the center of the material pile for measurement. It is used to detect the material ...
程宇 Test/Measurement
Detailed explanation of ARM application system development - system design based on S3C4510B (Second Edition)
Detailed explanation of ARM application system development - system design based on S3C4510B (Second Edition)...
zoujin ARM Technology
Seeking an example of 430 dual-machine serial communication
Seeking an example of 430 dual-machine serial communication...
ljk926 Microcontroller MCU
Multisim simulation IR2103
I used multisim to make a driver simulation, but I don't know where the problem is. When the signal generator outputs a square wave, it says there is a problem with the simulation. I have been looking...
深情不及久伴 Motor Drive Control(Motor Control)

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2230  538  1503  2713  2048  45  11  31  55  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号