400E-3C-8.25L

Description
Electric Fuse, 25A, 8250VAC, 80000A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size383KB,5 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

400E-3C-8.25L Overview

Electric Fuse, 25A, 8250VAC, 80000A (IR), Inline/holder

400E-3C-8.25L Parametric

Parameter NameAttribute value
MakerLittelfuse
Reach Compliance Codeunknown
body height403.2 mm
Body length or diameter247.6 mm
Circuit protection typeELECTRIC FUSE
Manufacturer's serial number400E-3C-8.25
Installation featuresINLINE/HOLDER
physical size247.6mm x 403.2mm
Rated breaking capacity80000 A
Rated current25 A
Rated voltage (AC)8250 V
surface mountNO
Terminal shapeEND CAP
Base Number Matches1
E Rated Medium Voltage Fuses
Current Limiting
“E” Rated fuses have time current characteristics designed
to provide current limiting protection for power transformers,
potential transformers, power centers, feeder centers, and
unit sub stations. When properly applied, they can protect
against high and low value fault currents.
NEMA Standards for “E” rated medium voltage fuses require
that fuses rated 100E or less open within 300 seconds (5
minutes) when subjected to an RMS value of 200-240% of
the fuse’s continuous current rating; and fuses with an “E”
rating larger than 100E must open within 600 seconds (10
minutes) when subjected to an rms current of 220-240% of
the fuse’s continuous current rating. These values establish
one point on the time-current curve.
Application Note:
Since these fuses are used for the protection of general
purpose circuits which may contain transformers, motors,
and other equipment producing inrush and/or overload cur-
rents, fuses should generally be rated at 140% of the normal
full load current, and circuits should be analyzed to ensure
that system load currents will not exceed the current rating
of the fuse.
CHARACTERISTICS
Voltage Rating:
2,400 volts – 38,000 volts
Current Range:
10E – 600E
OPTIONS
I
I
Hermetically Sealed for use in hazardous locations
(add “S” suffix to part number)
Clip-lock (CL) and bolt-in styles available.
3"DIA
6.38"
9.75"
Dim.A
(Clip
Center)
Dim.B
FIGURE 14
FIGURE 15
FIGURE 16
E
RATED
Catalog
Number
10E-1C-2.75
15E-1C-2.75
20E-1C-2.75
25E-1C-2.75
30E-1C-2.75
40E-1C-2.75
50E-1C-2.75
65E-1C-2.75
80E-1C-2.75
100E-1C-2.75
125E-1C-2.75
150E-1C-2.75
200E-1C-2.75
125E-2C-2.75
150E-2C-2.75
175E-2C-2.75
200E-2C-2.75
225E-2C-2.75
250E-2C-2.75
300E-2C-2.75
350E-2C-2.75
400E-2C-2.75
450E-2C-2.75
Old
Catalog
Number
LCX 10E
LCX 30E
LCX 40E
LCX 50E
LCX 65E
LCX 80E
LCX 100E
LCX 125E
LCX 150E
LCX 175E
LCX 200E
LCX 250E
LCX 300E
LCX 400E
Size
10E
15E
20E
25E
30E
40E
50E
65E
80E
100E
125E
150E
200E
125E
150E
175E
200E
225E
250E
300E
350E
400E
450E
Dim. A
(inches)
Dim. B
(inches)
Max
Interrupting
Rating
RMS (Asym)
7"
10.875"
80,000
7"
10.875"
80,000
Figure
Number
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
2.75 Max. KV
67
Please tell me the function of the pull-up resistor of this transistor
The transistor in the figure is used as a switch to drive the buzzer, but the function of R41 in the figure is to pull up and provide a certain level to the transistor. Here is a question. VCC will al...
zhandizhandi Analog electronics
Question + How to enter sleep mode on MSP430
How does MSP430 enter sleep mode? What is the power consumption of MSP430 in sleep mode?...
lyncxy119 Microcontroller MCU
The error reporting method does not match the delegate? What's going on?
peripheralPort.SerialPort bbport = new peripheralPort.SerialPort(); Thread read485port=new Thread(new ThreadStart(bbport.ReadPort)); read485port.Start(); public override bool ReadPort(int NumBytes, re...
painache Embedded System
NXP Technology Center has been revamped. Do you like this interface?
[font=微软雅黑][size=5]>>[url=https://www.eeworld.com.cn/zhuanti/eewNXPminisite/]NXP Technology Center[/url] has been redesigned! ! ! Do you like this interface? [/size][/font]:victory:...
EEWORLD社区 NXP MCU
Registry configuration when making a CAB installer for wince.
Everyone knows that the Windows directory of wince cannot save files when the power is off. When installing the WINCE driver, the relevant registry contains the DLL file name. If we do not put the DLL...
wangyg007 Embedded System
Ask the analog electronics expert about the power amplifier circuit
The amplifier uses TDA2030, and the circuit uses the standard application given by DATASHEET (Figure 1). I calculated it and it worked, but there was no output after it was actually built. I built hal...
fighting Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 847  780  2590  111  172  18  16  53  3  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号