EEWORLDEEWORLDEEWORLD

Part Number

Search
 PDF

BF030-24C-B0-0200-0220-0600-LD

Description
Board Connector, 24 Contact(s), 2 Row(s), Male, Straight, 0.079 inch Pitch, Surface Mount Terminal, Black Insulator,
CategoryThe connector    The connector   
File Size97KB,1 Pages
ManufacturerGlobal Connector Technology
Environmental Compliance
Download Datasheet Parametric View All

BF030-24C-B0-0200-0220-0600-LD Overview

Board Connector, 24 Contact(s), 2 Row(s), Male, Straight, 0.079 inch Pitch, Surface Mount Terminal, Black Insulator,

BF030-24C-B0-0200-0220-0600-LD Parametric

Parameter NameAttribute value
Termination typeSURFACE MOUNT
Plug contact pitch0.079 inch
Match contact row spacing0.079 inch
OptionsGENERAL PURPOSE
Insulator colorBLACK
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation option 1LOCKING
Number of connectorsONE
PCB contact patternRECTANGULAR
Contact materialCOPPER ALLOY
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Mixed contactsNO
PCB contact row spacing4.2 mm
Dielectric withstand voltage500VAC V
Filter functionNO
maximum insertion force2 N
Insulation resistance1000000000 Ω
Evacuation force-minimum value0.2 N
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
UL Flammability Code94V-0
GuidelineUL
Is it Rohs certified?Yes
ECCN codeEAR99
Is SamacsysN
YTEOL0
Objectid314413559
Reach Compliance CodeCompliant
Country Of OriginMainland China
body width0.157 inch
subject depth0.086 inch
body length0.945 inch
Durability100 Cycles
Rated current (signal)2 A
Contact to complete cooperationSN ON NI
Contact resistance20 mΩ
insulator materialLIQUID CRYSTAL POLYMER
Installation methodSTRAIGHT
Installation typeBOARD
PCB row number2
Number of rows loaded2
Terminal pitch2 mm
Connector typeBOARD CONNECTOR
Contact point genderMALE
Total number of contacts24
ULN 2803a and PLC usage issues
Hello everyone, I would like to ask a question: PLC s7 312 output is connected to the pull-up resistor 10kΩ connected to the input of uln 2803a, the COM terminal of uln 2803a is connected to 24v, and ...
Nickfzx PCB Design
How does ARM operate directly on physical addresses?
It turns out that adding the offset 0xA0000000 in MIPS is enough. What about ARM? How to do it? I am using S3C2440...
yuno1 ARM Technology
About EVC Controls
Is there any place where I can download third-party controls for EVC, like BCGCBPRO, TreeChart, etc. under VC?...
wdwcymwjy Embedded System
6410+DDR1 256MB
I am currently using Samsung's official BSP, which uses 128MB mDDR, but we are now using DDR1, which consists of four 32M x 16 DDR1 chips to form a 256MB memory. Let's use it as 128MB first. For debug...
cjw007 Embedded System
Is there any way to block public messages? It's a waste of time.
Is there any way to block public messages? It's a waste of time....
深圳小花 Talking
Design of multi-visual sensor measurement and control system based on CAN bus
5 CAN bus communication CAN bus is a multi-master field bus. Each node has the right to send information to other nodes. Its protocol is simple, real-time, reliable and anti-interference, high bus uti...
frozenviolet Automotive Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2846  2630  174  1752  797  58  53  4  36  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号