Parameter NameAttribute value
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-ON
Dielectric withstand voltage2500VRMS V
Switch typeROCKER SWITCH
Insulation resistance1000000000 Ω
Actuator typeROCKER
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact voltage (AC)250 V
Maximum contact current (DC)10 A
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Electrical life10000 Cycle(s)
End contact platingSILVER
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
Is SamacsysN
YTEOL8.89
Objectid312922510
Reach Compliance CodeCompliant
Country Of OriginUK
ECCN codeEAR99
Installation featuresPANEL MOUNT
Termination typeSCREW
center contact materialCOPPER
Center contact platingSILVER
End contact materialCOPPER
illuminationLAMP
surface mountNO
Actuator colorWHITE
Actuator materialPOLYAMIDE
Shell materialPOLYAMIDE
Actuator length0.354 inch
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
Terminal length0.437 inch
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
About the keyboard driver under PXA270
I would like to ask you all, we are using PXA270 platform + wince5.0. The customer gave us a hardware board and asked us to develop a driver. Originally, PXa270 has a keyboard interface, but the custo...
bluemoon Embedded System
Unveiling the ADI chip of the new Meizu PRO 6 Plus
[align=left][font=宋体]The following content is transferred from[/font]ADI[font=宋体]Chinese community:[/font][url=https://ezchina.analog.com/thread/14789]https://ezchina.analog.com/thread/14789[/url][/al...
新人不新 Analog electronics
Signals and Systems (3rd Edition)
Signals and Systems is a national key textbook for general higher education in the "Ninth Five-Year Plan" published by Higher Education Press. The editor is Zheng Junli, professor of the Department of...
arui1999 Download Centre
Can a 100A current flow through a PCB? Tips for setting up high current paths
The current of a normal PCB design will not exceed 10 A, or even 5 A. Especially in home and consumer electronics, the continuous working current on the PCB usually does not exceed 2 A. However, I rec...
btty038 PCB Design
Just saw this, I'll save it for later use of volatile
volatile is equivalent to telling the compiler that the things declared by it are changeable and uncertain, and may be changed by external programs (such as interrupt programs), and prohibiting the co...
yjch2009 Microcontroller MCU
hcnr201 isolation circuit problem
As shown in the picture, the simulation is good, giving a 0-5V sine wave, but after the actual board is powered on, the first op amp becomes hot and the power is also very high. What is the problem?...
关尔郑 Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 267  307  2540  1697  2283  6  7  52  35  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号