2646LPA222001L220V3/3

Description
Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2646LPA222001L220V3/3 Overview

Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2646LPA222001L220V3/3 Parametric

Parameter NameAttribute value
Objectid313143153
Reach Compliance CodeCompliant
Country Of OriginUK
ECCN codeEAR99
Is SamacsysN
YTEOL8.89
Installation featuresPANEL MOUNT
surface mountNO
Termination typeSCREW
Actuator colorBLACK
Actuator materialPOLYAMIDE
center contact materialSILVER
End contact materialSILVER
Shell materialPOLYAMIDE
Actuator length0.394 inch
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
Terminal length0.437 inch
Maximum contact voltage (AC)250 V
Insulation resistance1000000000 Ω
Switch typeROCKER SWITCH
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-ON
Actuator typeROCKER
Other features220VAC GREEN FLUROSCENT LAMP
Contact (AC) maximum rated power R load0.16HP@250VAC
Dielectric withstand voltage2500VRMS V
Maximum contact current (DC)10 A
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Electrical life10000 Cycle(s)
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
【Learn Power Supply from TI】 Series------TI Full-color LED Display Solution
[align=left][b][color=black] [color=red]This is the wonderful lecture courseware of Mr. Li Wei, a power engineer of TI, on October 16, 2012. If you like it, please download and watch it! [/color][size...
qwqwqw2088 Analogue and Mixed Signal
5 yuan a clamp meter
Last time I recommended a multimeter for 5 yuan to you , and this time I bought a few clamp meters for 5 yuan each.Uses 9V batteryThe workmanship is average and suitable for making electrician meters....
dcexpert DIY/Open Source Hardware
[FPGA Open Source Tutorial Series] Chapter 13B Building a Simple Application System for Serial Port Transmission and Storage Dual-Port RAM
[align=center][color=#000][size=15px][size=6][b]Build a simple application system with serial port receiving and transmitting and storage dual ports[/b][b]RAM[/b][b][/b][/size][/color][/align][align=c...
芯航线跑堂 FPGA/CPLD
What happened to my board?
My board is very strange today. EVC can be synchronized to the board, but when I press the browse button of the synchronization software, I can't see the files in my device. In other words, I can't tr...
像见 Embedded System
2.4G antenna design reference on PCB board
[i=s]This post was last edited by qwqwqw2088 on 2020-3-11 09:16[/i]For 2.4G PCB antenna, if cost and size are not considered, other antennas can be selected, such as patch antenna (small size, medium ...
qwqwqw2088 Wireless Connectivity
How to simulate photoelectric counting module in Proteus?
How can I simulate the photoelectric counting module in Proteus? I searched and found that someone said to use IRLINK. This photoelectric coupling is for infrared simulation. Is there any good way to ...
LcCode Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1171  2761  2420  486  1249  24  56  49  10  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号