Part Number

Search

2641LPC42901L110V1

Description
Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2641LPC42901L110V1 Overview

Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2641LPC42901L110V1 Parametric

Parameter NameAttribute value
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
Country Of OriginUK
ECCN codeEAR99
Is SamacsysN
YTEOL8.89
Objectid312990347
Reach Compliance CodeCompliant
Termination typeSCREW
End contact materialCOPPER
Shell materialPOLYAMIDE
surface mountNO
Center contact platingSILVER
Installation featuresPANEL MOUNT
Actuator colorORANGE
Actuator materialPOLYAMIDE
center contact materialCOPPER
Actuator length0.394 inch
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
Terminal length0.437 inch
Actuator typeROCKER
Other features110VAC FLUORESCENT LAMP
Contact functionON-OFF
Contact (DC) maximum rated R load10A@24VDC
Maximum contact voltage (AC)250 V
Dielectric withstand voltage2500VRMS V
Insulation resistance1000000000 Ω
Switch typeROCKER SWITCH
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
End contact platingSILVER
Maximum contact current (DC)10 A
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Electrical life10000 Cycle(s)
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
ARMQQ exchange group 65564961
ARMQQ exchange group 65564961...
tang_lixin ARM Technology
MCU serial communication
One microcontroller sends, and the other receives. Now I have a problem. After each string is sent, the sending microcontroller has to delay for about 400us before it can continue to send the next str...
xyyyxmh Embedded System
Ready-made USB interface communication module
Hello everyone! We have designed an acquisition and storage module. This module is designed using STM32+128MByte flash, which means that the acquisition and storage parts are already completed, and th...
qiwan Programming Basics
xp system and virtual operating system linux in microsoft, how to let linux surf the internet
Description: The network configuration of my real host: IP Address (192.168.16.95) Gateway is (192.168.16.1) DNS is (202.96.134.133) I access the Internet through the landlord's hub. It binds my IP to...
zdhm Linux and Android
【MSP430 Sharing】Transplantation of embedded operating system μC/OS-Ⅱ on MSP430F168 microcontroller
This article presents a method for porting the embedded operating system I~C/OS-II to a microcontroller with less RAN space. Based on this method, I~C/OS-II was successfully ported to the NS P430FI68 ...
鑫海宝贝 Microcontroller MCU
Circuit Analysis Basics
[i=s]This post was last edited by paulhyde on 2014-9-15 09:16[/i] Basics of circuit analysis - still learning, a little behind!...
hanyunbo123 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2377  1140  1976  2054  1317  48  23  40  42  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号