EEWORLDEEWORLDEEWORLD

Part Number

Search

E301J50AV2ME22

Description
ROCKER SWITCH, 3PDT, LATCHED, 5A, 28VDC, THROUGH HOLE-RIGHT ANGLE
CategoryMechanical and electronic products    switch   
File Size2MB,14 Pages
ManufacturerC&K
Download Datasheet Parametric View All

E301J50AV2ME22 Overview

ROCKER SWITCH, 3PDT, LATCHED, 5A, 28VDC, THROUGH HOLE-RIGHT ANGLE

E301J50AV2ME22 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerC&K
Reach Compliance Codenot_compliant
ECCN codeEAR99
Actuator typeLONG ROCKER
body width16.31 mm
body height12.7 mm
Body length or diameter14.35 mm
Contact (AC) maximum rated R load5A@125VAC
Maximum contact current (AC)5 A
Maximum contact current (DC)5 A
Contact (DC) maximum rated R load5A@28VDC
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)28 V
Electrical life30000 Cycle(s)
JESD-609 codee0
Manufacturer's serial numberE
Installation featuresTHROUGH HOLE-RIGHT ANGLE
Maximum operating temperature85 °C
Minimum operating temperature-30 °C
sealEPOXY TERMINAL SEALED
surface mountNO
Switch actionLATCHED
switch function3PDT
Switch typeROCKER SWITCH
Terminal surfaceTin/Lead (Sn/Pb) - with Nickel (Ni) barrier
Termination typeSOLDER
Base Number Matches1
C&K E Series
Sealed Miniature Rocker and Lever Handle Switches
Features/Benefits
Sealed against solder and cleaning
Typical Applications
Telecommunications
process contaminants
Instrumentation
ESD Resistance—all actuator options
Computers & peripherals
Rocker, case & bushing UL 94V-0
RoUS compliant
Models Available
Specifications
CONTACT RATING: B contact material: 0.4 VA max. @ 20 V AC or
DC max. Q contact material (E1XX & E2XX Models): 7.5 AMPS
@125 V AC or 28 V DC; 3 AMPS @ 250 V AC. (E3XX Models):
5 AMPS @ 125 V AC or 28 V DC; 2 AMPS @ 250 V AC.
See page H-37 for additional ratings.
ELECTRICAL LIFE: E1XX and E2XX models: 40,000 make-and-break
cycles at full load. E3XX models: 30,000 cycles.
CONTACT RESISTANCE: Below 10 m
typ. initial @
2-4 V DC, 100 mA, for both silver and gold plated contacts.
INSULATION RESISTANCE: 109
min.
ELECTROSTATIC DISCHARGE (ESD) OPTION: All actuator
options: 15,000 V DC max. @ sea level, actuator to terminals.
DIELECTRIC STRENGTH: 1000 Vrms min. @ sea level.
OPERATING TEMPERATURE: –30ºC to 85ºC.
SOLDERABILITY: Per MIL-STD-202F method 208D, or
EIA RS-186E method 9 (1 hour steam aging).
Materials
CASE & BUSHING: Glass filled nylon 6/6, flame retardant, heat
stabilized (UL 94V-0).
ACTUATOR: Nylon, black standard, internal o-ring seal standard
with all actuators.
FRAME: Spring steel, black standard.
SWITCH SUPPORT: Brass or steel, matte-tin plated.
ACTUATOR PIVOT & MOUNTING BRACKET: Nylon.
ACTUATOR PIVOT RETAINER: Stainless steel.
CONTACTS & TERMINALS: B contact material: Copper alloy, with gold
plate over nickel plate. Q contact material: Copper alloy, silver
plated. See page H-37 for additional contact materials.
TERMINAL SEAL: Epoxy.
HARDWARE: Nut, Screw & Lockwasher: Stainless steel.
Standoff: Nylon standard, aluminum available, consult Customer
Service Center.
NOTE:
Any models supplied with Q, B, G, S P & R contact material are RoHS compliant. For
the latest information regarding RoHS compliance, please go to: www.ittcannon.com/rohs.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages H-26 through H-39. For additional options not shown in catalog, consult Customer Service Center. All
models are process sealed to withstand machine soldering temperatures and pressure wash cleaning methods.
Rocker
Switch Function
E101
SP On-None-On
E103
SP On-Off-On
E105
SP Mom.-Off-Mom.
E107
SP On-Off-Mom.
E108
SP On-None-Mom.
E201
DP On-None-On
E203
DP On-Off-On
E205
DP Mom.-Off-Mom.
E207
DP On-Off-Mom.
E208
DP On-None-Mom.
E211
DP On-On-On
E213
DP On-On-Mom.
E215
DP Mom.-On-Mom.
E301
3P On-None-On
Actuator
J1
.531 long rocker
J2
Lever
J3
.906" long rocker
J11
Rocker with frame
J21
Lever with frame
J50
.362" long rocker
J60
Lever
J90
Lever
Terminations
A
Right angle, PC thru-hole
AV2
Vertical right angle, PC thru-hole
C
PC Thru-hole
Z
Solder lug
A3
Right angle, snap-in, PC thru-hole
AV3
Vertical right angle, snap-in, PC thru-hole
V3
.460" high, V-bracket
V4
.630" high, V-bracket
V5
Vertical right angle, PC thru-hole
V6
.460" high, V-bracket
V7
.630" high, V-bracket
V8
.953" high, V-bracket
V21
.555" high, V-bracket, snap-in
V31
.460" high, V-bracket, snap-in
Contact Material
B
Gold
K
Gold, tin-lead
P
Gold, matte tin
Q
Silver
M
Silver, tin-lead
S
Silver, matte-tin
G
Gold over silver
L
Gold over silver, tin-lead
R
Gold over silver, matte-tin
Seal
E
Epoxy
Actuator Color
2
Black
Frame Color
3
Red
2
Black
NONE
No frame color required
Metal Frame Color
(J11, J21 Actuators)
2
Black
H
H–26
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
www.ittcannon.com
Commissioned to develop industrial robot control system, if interested, please reply QQ79500116
Seven-degree-of-freedom robot, multi-robot industrial CAN bus control...
villaining Robotics Development
Looking for a battery module development program based on the SMBus1.1 protocol
[color=#222222][backcolor=rgb(238, 238, 238)][font=sans-serif]The BQ306 control chip is used internally, and the SMBUS1.1 protocol is followed. It is required to be able to read the battery capacity, ...
christopher7 ARM Technology
Using C2000 Launchpad to modify an XDS100 to simulate BBB
It's worth my hard work for several days... First of all, I would like to thank @石玉 for getting me a C2000 Launchpad. I can download and debug it now, but I want to ask, can it be faster?...
airqj Microcontroller MCU
51 MCU learning materials
Especially suitable for beginners...
deng3586002 51mcu
Why can't I enter the interrupt I set?
I used MSP430G2121 microcontroller to write a program for a rotary encoder switch. The encoder switch is EC11 (30 points and 15 pulses). I used the falling edge to trigger the interrupt. I set the fal...
wanyong19860402 Microcontroller MCU
How to connect to LAN host via GPRS module?
Recently I was working on a project using IWOW's TR800 for GPRS data transmission applications, and suddenly a question occurred to me. Since my GPRS module is assigned an intranet IP, if I want to co...
chrislove RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2637  2256  1878  1996  2650  54  46  38  41  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号