EEWORLDEEWORLDEEWORLD

Part Number

Search

MA-S20ASC10

Description
磁性 磁簧开关 磁体 NC 电缆引线 盒
CategoryThe sensor    MagneticSensor   
File Size609KB,6 Pages
ManufacturerOmron Automation and Safety
Download Datasheet Parametric View All

MA-S20ASC10 Overview

磁性 磁簧开关 磁体 NC 电缆引线 盒

MA-S20ASC10 Parametric

Parameter NameAttribute value
category
MakerOmron Automation and Safety
seriesMA-STI
PackageBulk
type磁簧开关
Output typeNC
Actuator materialmagnet
Termination styleCable leads
Voltage - Power supply230VAC
must work-
must be released-
Operating temperature-10°C ~ 55°C(TA)
Package/casingbox
Basic product numberMA-S20
Safety Interlock Switches
MA-S Series
Stainless Steel Magnetically Actuated
Safety Interlock Switches and Actuators
• Stainless steel cases—both switch and actuator are housed in stainless steel
for applications that require the use of this robust and corrosion resistant
material
• Large selection—choose from a variety of contact configurations housed in
stainless steel to satisfy the most demanding applications
• NEMA 6 enclosure enables the MA-S Series switches to satisfy most applica-
tion requirements
• Misalignment tolerant—the non-contact actuation of the MA-S Series switches
makes them very tolerant to misalignment of up to 10 mm (0.39 in.)
• High temperature—the MA-S switches and cables are designed to operate in
temperatures up to 125°C (257°F)
• Long life—the MA-S Series safety interlock switches are designed for a
minimum of one million actuations
• A Rapid Delivery Product: Select models are available for shipment today or
within 3 to 5 days
R
C
US
Specifications
Electrical
Safety Contacts:
Conforms to EN1088, EN292, EN60204-1
UL and C-UL listed
G
All Models Unless Indicated
AC models
DC models
MA-S2, S21, 34, 35, 36
MA-S2, S21, 34, 35,S36
AC models
DC models
AC models
DC models: All except MA-35
DC model: MA-35
AC models
DC models: All except MA-35
AC models
DC models
Safety Contact Operating Distance:
Auxiliary Contacts:
Aux. Contact Operating Distance:
Safety Rated Voltage:
Safety Rated Current:
Internal Fuse
External Fuse (Customer Supplied)
Electrical Life:
Mechanical—Special Safety Reed
Closing Time:
Drop-Out Time:
Bounce Time:
Shock:
Vibration:
Mechanical
Mounting:
Case & Actuator Material:
Wiring Connection:
Weight:
Color:
Mechanical Life:
Environmental
Protection:
Operating Temperature:
MA-S2, 36 — 1 N/C
MA-S20, S21 — 2 N/C
MA-S2, 34, 36 — 1 N/C
MA-S20, S21, 35, 36 — 2 N/C
Make 7-12 mm (0.28-0.47 in.); Break 12-25 mm (0.47 to 0.98 in.)
1 N/O
Make 10-13 mm (0.39-0.51 in.); Break 8-10 mm (0.31-0.39 in.)
230 VAC
30 VDC
2 A max., fuse externally 1.6 A quick acting
1 A, fuse externally 800 mA quick acting
0.3 A max., fuse externally 0.2 A quick acting
2 A fast acting
1 A fast acting
1.6 A fast acting
0.8 A fast acting
1 x 10
6
Safety.
Aux.
3.0 mS
0.5 mS
2.1 mS
0.3 mS
0.7 mS
0.7 mS
10 G
10 G
10 G, 50 to 100 Hz
Any position
Stainless steel
Various lengths or male M12 micro connector
600 g (1 lb. 5 oz.)
Stainless steel
10 x 10
6
IP67 (NEMA 6)
-10 to 95°C (14 to 203°F); Connector Models: -10 to 55°C (14 to 131°F)
-10 to 55°C (14 to 131°F)
-10 to 125°C (14 to 257°F)
-20 to 70°C (-4 to 158°F)
MA-S2, S20, S21
MA-34, 35, 36
MA-35HT
EN1088, EN292, EN60204-1
CE marked for all applicable directives
MA-S2, S20, S21
UL and C-UL
MA-34, 35, 36
UL and C-UL
Reliability Data
per EN ISO 13849-1: – B10d: 2.00E+06
Specifications are subject to change without notice. Note: The safety contacts of the STI switches are described as normally closed (N/C) i.e., with the
guard closed, actuator in place, and the machine able to be started.
Storage Temperature
Compliance
Standards:
Approvals/Listings:
www.omron247.com
G-103
How to take advantage of the flexibility of the integrated ADC in MCUs to differentiate your design from the competition - Part 1
Have you ever wondered why MSP microcontrollers (MCUs) offer flexibility in their integrated analog-to-digital converters (ADCs), such as programmable resolution or power modes? This level of flexibil...
maylove Microcontroller MCU
The code copy part of 44b0?
;********************************************************;Copy and paste RW data/zero initialized data *;********************************************************LDR r0, =|Image$$RO$$Limit| ; is the en...
yanglong0322 ARM Technology
Problems with Bluetooth transparent transmission mode and AT mode
I used the transparent mode to connect the Bluetooth module and the mobile phone Bluetooth. After the transparent mode of this Bluetooth module was set, it took effect after powering on again. I want ...
chenbingjy RF/Wirelessly
The entry point of an embedded program is not main but reset
A question for those who develop embedded systems: Is the main() function the place where the program starts to execute? My teachers in college always said that the entry point of the program is the m...
haopijin NXP MCU
ZigBee Gateway
Dear experts, I am a senior graduate designer. I am not very good at designing a ZigBee gateway based on ESP8266. :) I would like to ask for your guidance....
light龙少女 RF/Wirelessly
Several hidden security tools in WinXP
Several hidden security tools in WinXPIn Windows XP, there are more than 100 various tools hidden on the installation CD, which cover all aspects of the operating system, from network, Internet connec...
wo2000ailuo RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2  1958  1239  2206  2416  1  40  25  45  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号