MFS-12P21C6

Description
磁性 磁簧开关 磁体 NO/NC 电缆引线 盒
CategoryThe sensor    MagneticSensor   
File Size546KB,5 Pages
ManufacturerOmron Automation and Safety
Download Datasheet Parametric View All

MFS-12P21C6 Overview

磁性 磁簧开关 磁体 NO/NC 电缆引线 盒

MFS-12P21C6 Parametric

Parameter NameAttribute value
category
MakerOmron Automation and Safety
seriesMFS-STI
PackageBulk
type磁簧开关
Output typeNO/NC
Actuator materialmagnet
Termination styleCable leads
Voltage - Power supply24VDC
must work-
must be released-
Operating temperature-10°C ~ 55°C(TA)
Package/casingbox
Basic product numberMFS-12
Safety Interlock Switches
MFS
For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specifc web page.
Magnetic Ferroresonant Stand-
Alone Safety Interlock Switch
• Tamper resistant—the combination of magnetic and ferroresonant
signals required to close the safety contacts makes the MFS very
tamper resistant
• Stand-alone—use for lower risk applications as a stand-alone
safety switch allowing direct switching of relays and contactors up
to 2 A at 230 VAC
• MFS-11 provides a visible LED which illuminates green when the
actuator is in range and contacts are closed
• MFS-12 provides a dual color LED indicator. The LED illuminates
green when the actuator is in range and the contacts are closed.
The LED illuminates Red when the actuator is out of range and
contacts are open.
• Compact size—mounts easily on 1-in. square tubing
• Use with safety monitoring relays in applications requiring a higher
level of safety reliability
• NEMA 4 enclosure enables water washdown cleaning
• A Rapid Delivery Product: Select models are available for shipment today or
within 3 to 5 days
R
C
US
Specifications
Electrical
Power Supply:
Power Consumption:
Max Cable Length:
Safety Outputs:
Auxiliary Contact:
Operating Distance:
Minimum Gap:
Safety Max Switched Current/Voltage:
Aux. Max. Switched Current/Voltage:
Max. Output Fuse:
Mechanical
Mounting:
Case Material:
Weight:
Color:
Indication:
Mechanical Life:
Environmental
Protection:
Operating Temperature:
Vibration/Shock:
Compliance
Standards:
MFS-11
24 VDC
2 VA
100 m
1 N/C or 2 N/C
ON = 6-9 mm; OFF = 10-12 mm
2 mm
2 A / 230 VAC; 2 A / 30 VDC
2 A / 230 VAC; 2 A / 30 VDC
2 A quick acting
2 x M4 screws, supplied
ABS
198 g (7 oz.)
Blue
Green = Guard Closed
10 x 10
6
IP67
-10 to 55°C (-14 to 131°F)
50-100 Hz / 10 g
MFS-12
Conforms to EN1088, EN292,
EN60204-1, EN954-1, EN947-5-3,
EN60947-5-1, EN50081, EN50082,
EN61000-6-2
UL and C-UL listed
G
2 N/C
1 N/O
Green = Guard Closed
Red = Guard Open
EN1088, EN292, EN60204-1, EN954-1, EN947-5-3, EN60947-5-1,
EN50081, EN50082, EN61000-6-2
Approvals/Listings:
CE marked for all applicable directives, UL and C-UL
Safety Category:
Cat. 3 per EN954-1 when used with an appropriate safety
monitoring relay
Specifications are subject to change without notice.
Note: The safety contacts of the STI switches are described as normally closed (N/C)—
i.e., with the guard closed, actuator in place, and the machine able to be started.
www.omron247.com
G-111
arm assembly instruction manual
...
白手梦想家 stm32/stm8
How to convert out file to asm file
[i=s] This post was last edited by dontium on 2015-1-23 13:24 [/i] Could any expert help meHow can I convert the out file to asm file...
xb123 Analogue and Mixed Signal
National Semiconductor's guidance document on switching power supply PCB design is highly recommended
National Semiconductor's guidance document on switching power supply PCB design is highly recommended...
simonprince PCB Design
ESD Threats to Portable Devices
The contact and separation of two non-conductive materials causes the transfer of electrons, thereby generating additional charges on each object. ESD occurs when the accumulated static charge is disc...
ESD技术咨询 Industrial Control Electronics
What does void rampgen_calc(RAMPGEN *v) mean in SVPWM?
void rampgen_calc(RAMPGEN *v) {// Compute the angle ratev->Angle += _IQmpy(v->StepAngleMax,v->Freq);// Saturate the angle rate within (-1,1)if (v->Angle>_IQ(1.0))v->Angle -= _IQ(1.0);else if (v->Angle...
jsw410923 DSP and ARM Processors
LM4F231H5QR QEI function ph1A port can not read pulse? The condition is that phA1 is connected to the frequency of 10-100KHZ.
unsigned int i;signed int j1=0,j0=0; // // The FPU should be enabled because some compilers will use floating- // point registers, even for non-floating-point code. If the FPU is not // enabled this w...
sxjmcu Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2297  1679  1649  1716  790  47  34  35  16  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号