EEWORLDEEWORLDEEWORLD

Part Number

Search

MA-S2ASC3

Description
磁性 磁簧开关 磁体 NO/NC 电缆引线 盒
CategoryThe sensor    MagneticSensor   
File Size609KB,6 Pages
ManufacturerOmron Automation and Safety
Download Datasheet Parametric View All

MA-S2ASC3 Overview

磁性 磁簧开关 磁体 NO/NC 电缆引线 盒

MA-S2ASC3 Parametric

Parameter NameAttribute value
category
MakerOmron Automation and Safety
seriesMA-STI
PackageBulk
type磁簧开关
Output typeNO/NC
Actuator materialmagnet
Termination styleCable leads
Voltage - Power supply230VAC
must work-
must be released-
Operating temperature-10°C ~ 95°C(TA)
Package/casingbox
Basic product numberMA-S2
Safety Interlock Switches
MA-S Series
Stainless Steel Magnetically Actuated
Safety Interlock Switches and Actuators
• Stainless steel cases—both switch and actuator are housed in stainless steel
for applications that require the use of this robust and corrosion resistant
material
• Large selection—choose from a variety of contact configurations housed in
stainless steel to satisfy the most demanding applications
• NEMA 6 enclosure enables the MA-S Series switches to satisfy most applica-
tion requirements
• Misalignment tolerant—the non-contact actuation of the MA-S Series switches
makes them very tolerant to misalignment of up to 10 mm (0.39 in.)
• High temperature—the MA-S switches and cables are designed to operate in
temperatures up to 125°C (257°F)
• Long life—the MA-S Series safety interlock switches are designed for a
minimum of one million actuations
• A Rapid Delivery Product: Select models are available for shipment today or
within 3 to 5 days
R
C
US
Specifications
Electrical
Safety Contacts:
Conforms to EN1088, EN292, EN60204-1
UL and C-UL listed
G
All Models Unless Indicated
AC models
DC models
MA-S2, S21, 34, 35, 36
MA-S2, S21, 34, 35,S36
AC models
DC models
AC models
DC models: All except MA-35
DC model: MA-35
AC models
DC models: All except MA-35
AC models
DC models
Safety Contact Operating Distance:
Auxiliary Contacts:
Aux. Contact Operating Distance:
Safety Rated Voltage:
Safety Rated Current:
Internal Fuse
External Fuse (Customer Supplied)
Electrical Life:
Mechanical—Special Safety Reed
Closing Time:
Drop-Out Time:
Bounce Time:
Shock:
Vibration:
Mechanical
Mounting:
Case & Actuator Material:
Wiring Connection:
Weight:
Color:
Mechanical Life:
Environmental
Protection:
Operating Temperature:
MA-S2, 36 — 1 N/C
MA-S20, S21 — 2 N/C
MA-S2, 34, 36 — 1 N/C
MA-S20, S21, 35, 36 — 2 N/C
Make 7-12 mm (0.28-0.47 in.); Break 12-25 mm (0.47 to 0.98 in.)
1 N/O
Make 10-13 mm (0.39-0.51 in.); Break 8-10 mm (0.31-0.39 in.)
230 VAC
30 VDC
2 A max., fuse externally 1.6 A quick acting
1 A, fuse externally 800 mA quick acting
0.3 A max., fuse externally 0.2 A quick acting
2 A fast acting
1 A fast acting
1.6 A fast acting
0.8 A fast acting
1 x 10
6
Safety.
Aux.
3.0 mS
0.5 mS
2.1 mS
0.3 mS
0.7 mS
0.7 mS
10 G
10 G
10 G, 50 to 100 Hz
Any position
Stainless steel
Various lengths or male M12 micro connector
600 g (1 lb. 5 oz.)
Stainless steel
10 x 10
6
IP67 (NEMA 6)
-10 to 95°C (14 to 203°F); Connector Models: -10 to 55°C (14 to 131°F)
-10 to 55°C (14 to 131°F)
-10 to 125°C (14 to 257°F)
-20 to 70°C (-4 to 158°F)
MA-S2, S20, S21
MA-34, 35, 36
MA-35HT
EN1088, EN292, EN60204-1
CE marked for all applicable directives
MA-S2, S20, S21
UL and C-UL
MA-34, 35, 36
UL and C-UL
Reliability Data
per EN ISO 13849-1: – B10d: 2.00E+06
Specifications are subject to change without notice. Note: The safety contacts of the STI switches are described as normally closed (N/C) i.e., with the
guard closed, actuator in place, and the machine able to be started.
Storage Temperature
Compliance
Standards:
Approvals/Listings:
www.omron247.com
G-103
What is TV_RM? What is its function?
This is the 24V input power processing part on a microcontroller circuit board. What is TV_RM in the red circle? Is it a TVS tube? After being connected in parallel with the resistor, both ends are co...
frily Analog electronics
WinCE+CDMA Dial-up Internet Access
When I dial up to the Internet with CDMA in Wince 5.0, it prompts that the port opening fails. Do I need to power the CDMA first when dialing? If so, how do I power it?...
amanonline Embedded System
Triode Class A Power Amplifier
[img]file:///C:\Usersain\AppData\Roaming\Tencent\Users\1061862232\QQ\WinTemp\RichOle\$F9{79B`]L{~%5OCNWPFKM8.png[/img]Help! Why is it that when I use a triode to make a Class A amplifier, the input AC...
rainnnn Analog electronics
[Antique Problem Solving] How to solve the problem of multiple interrupt sources using C under DOS?
main() { while(1) { If there is a serial port interrupt, fill this byte into the buffer; if (the buffer is already a complete frame) process (display); if (there is a keyboard interrupt) process the k...
lyzj321 Embedded System
Is it necessary to use Renesas chips in the rematch?
[i=s]This post was last edited by paulhyde on 2014-9-15 03:12[/i] Does the semi-final have to use Renesas chips? Does anyone know?...
黄礼森 Electronics Design Contest
Application of capacitors in circuit design
Background: In order to coordinate the more comprehensive knowledge points of circuit design, I will introduce various commonly used devices and design concepts in circuit design in the near future, s...
灞波儿奔 Energy Infrastructure?

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2329  1624  1533  623  1646  47  33  31  13  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号