Part Number

Search

3-1393809-6

Description
通用 继电器 可插
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

3-1393809-6 Online Shopping

Suppliers Part Number Price MOQ In stock  
3-1393809-6 - - View Buy Now

3-1393809-6 Overview

通用 继电器 可插

3-1393809-6 Parametric

Parameter NameAttribute value
category
MakerTE Connectivity
seriesV23154, AXICOM
PackageBulk
Installation typePlugable
coil voltage48VDC
Contact shape-
Rated contact (current)2 A
switching voltage125VAC,150VDC - 最大
coil current15 mA
Coil typeNo latch
characteristic-
Termination stylePlug-in
Sealing level-
coil insulation-
Must pull in voltage-
Voltage must be released-
operating hours7.5 ms
release time3 ms
Operating temperature-40°C ~ 70°C
Contact materialSilver(Ag),Gold(Au)
Relay typeUniversal
Coil resistance3.2 kOhms
Basic product number1393809
Signal Relays
Cradle N Relay V23154/V23162
n
n
n
n
n
n
AXICOM
Multi purpose relay
Highly reliable
Great variety of contact arrangements and materials to meet
specific applications
Contacts for signal loads and currents up to 5 A
DC coil, operating voltage 1.5VDC to 125VDC; AC, latching and non-
latching coils on request
Sockets for easy and quick mounting of relays
Typical applications
Measurement and control equipment, control equipment in nuclear
powerplant, press controls with high safety requirements (force-guided
springs), telecommunications
Contact Data
Product code block 3
Contact arrangement
Max. switching voltage
Rated current
Limiting continuous current
at max. ambient temperature
2A
Breaking capacity max.
35 to 70W
see DC load breaking capacity curve below 50VA
Contact material
silver, gold-flashed
Contact style
single contact
Frequency of operation, without load, max. 50 ops./s
Operate / release time typ.
7.5/3ms
Mechanical endurance
app. 10
7
ops.
Max. DC breaking capacity, contact sets B1xx, C1xx
150
V_
120
B104/B110/B112
B604/B610/B612
C104/C110/C112
C404/C410
F104 to F107
max. 4 form C (4 CO)contacts, 2 form B (2 NC) contacts or 6 form A (6 NO) contacts (see product code table)
150VDC
36VDC
150VDC
36VDC
250VDC
125VAC
30VAC
125VAC
30VAC
250VAC
2A
0.2A
2A
0.2A
5A
2A
5W, 5VA
-
gold F
single contact
50 ops./s
7.5/3ms
app. 10
7
ops.
2A
35 to 70W
50VA
silver, gold-flashed
bifurcated contacts
50 ops./s
7.5/3ms
app. 10
7
ops.
2A
5W, 5VA
-
gold F
bifurcated contacts
50 ops./s
7.5/3ms
app. 10
7
ops.
5A
50 to 140W
500VA
silver, gold-flashed
single contact
10 ops./s
7.5/3ms
app. 10
7
ops.
Max. DC breaking capacity, contact sets F1xx
250
V_
200
U
100
140 W
70 W
U
150
80
100
80
100 W
60
60
50
DC voltage [VDC]
50
DC voltage [VDC]
safe breaking, no stationary arc
contact material Ag, gold flashed
40
40
40 W
safe breaking, no stationary arc
contact material Ag, gold flashed
50 W
30
30
0,3
0,4
0,5
0,6
0,8
1
1,5
DC current [A]
I
2A
20
0,2
0,3
0,4
0,5
0,6
0,8
1
1,5
DC current [A]
I
2
3
4
5A
04-2017, Rev. 0417
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
Microcontroller Experiment and Practice Tutorial
Microcontroller experiment and practical tutorial....
zhaozhi0810 MCU
How to grow quickly in a business ~ Sharing personal experience
After I started to manage this section, I didn't know how to start. After thinking about it, I still felt that I should write something. Should I write about my friends in the weekly report? Or write ...
绿茶 Talking about work
[FPGA 100 Questions] How to design the synchronization of asynchronous signals?
Often in design, we need to synchronize the design of asynchronous signals. The simplest example is asynchronous serial port design. Regarding how to synchronize asynchronous signals, the following di...
eeleader FPGA/CPLD
Has anyone configured a WINCE4.2 development environment in a virtual machine? Please tell me how to do it.
Selection of virtual machine Basic OS selection OS in virtual machine PlatForm Buider 4.2 is the best, but it is OK if it is not. This is very important, it will not work without it Programming tool E...
lylhust Embedded System
Question G
[i=s]This post was last edited by paulhyde on 2014-9-15 09:26[/i] I have useful information about Question G, I hope it is useful to you all....
sz_jian Electronics Design Contest
100 Questions on Microcontroller Application Programming Skills (PDF format, recommended download)
[font=宋体][size=4]Instructions: This document lists 100 corresponding targeted questions from several aspects, such as "Assembly language, basic characteristics of single-chip microcomputers", "How to ...
gnkjmcu MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2072  2661  563  1176  1818  42  54  12  24  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号