EEWORLDEEWORLDEEWORLD

Part Number

Search

3100-11-120-23

Description
Board Connector, 20 Contact(s), 1 Row(s), Male, Straight, 0.156 inch Pitch, Solder Terminal, White Insulator, Receptacle
CategoryThe connector    The connector   
File Size1MB,9 Pages
ManufacturerMethode Electronics Inc.
Download Datasheet Parametric View All

3100-11-120-23 Overview

Board Connector, 20 Contact(s), 1 Row(s), Male, Straight, 0.156 inch Pitch, Solder Terminal, White Insulator, Receptacle

3100-11-120-23 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codeunknown
ECCN codeEAR99
body width0.31 inch
subject depth0.355 inch
body length3.11 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationTIN OVER NICKEL
Contact completed and terminatedTIN OVER NICKEL
Contact point genderMALE
Contact materialBRASS
contact modeRECTANGULAR
Contact resistance5 mΩ
Contact styleSQ PIN-SKT
DIN complianceNO
Dielectric withstand voltage1500VAC V
Filter functionNO
IEC complianceNO
maximum insertion force8.896 N
Insulation resistance500000000000 Ω
Insulator colorWHITE
insulator materialPOLYESTER
JESD-609 codee3
MIL complianceNO
Manufacturer's serial number3100
Plug contact pitch0.156 inch
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number1
Number of rows loaded1
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
polarization keyHOUSING SIDE
Rated current (signal)7 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.737 inch
Terminal pitch3.96 mm
Termination typeSOLDER
Total number of contacts20
UL Flammability Code94V-0
Evacuation force-minimum value.556 N
Base Number Matches1
.156" (3.96mm) Single Row
Through Hole, Vertical Headers
3100 SERIES
(“TERMACON”)
PART NUMBER LEGEND
31XX-1-XXX-XX
PIN NUMBER, DIMS “A” & “B”
(SEE TABLE II)
NUMBER OF PINS
(SEE TABLE I)
PIN STYLE: “1” IS .045 SQ., “2” IS .045 RD.
INSULATOR TYPE
(STRAIGHT)
PIN PLATING
(SEE NOTE 3)
INSULATOR MATERIAL
(SEE NOTE 1)
MATING CONNECTORS: 3000 SERIES AND 3300 SERIES CRIMP
OR IDC STYLE CONNECTORS
North and South America:
Methode Electronics, Inc. Connector Products
1700 Hicks Road • Rolling Meadows, IL 60008 USA
847-392-3500 • Toll Free: 800-323-6864 • Fax: 847-392-9404
Email: info@methode.com • Web: www.methode.com/connector/index.html
Europe:
Methode Electronics Ireland, Ltd.
Unit H, Crossagalla Business Park, Ballysimon Rd. • Limerick, Ireland
+353 (0) 61 401222 • Fax: +353 (0) 61 401942
Email: info@methode.ie • Web: ireland.methode.com/main.html
Far East:
Methode Electronics Far East, Pte. Ltd.
1 Tuas Lane, Jurong Town • Singapore 638610
65-68615444 • Fax: 65-68614777
Email: sales@methode.com.sg • Web: www.methode.com/mefe/index.html
Ten elements to become a great engineer
First: Strong analytical skills: Ability to continuously examine things and think about ways to make them work better. Good engineers are naturally curious. Second, attention to detail: Even the sligh...
aone2008 Industrial Control Electronics
Is it possible to label people and then identify them through sensors (like RFID, but without the need for people to wear tags)?
RT, let me give you another example that I came up with. For example, when I enter the door, I magnetize people, and then use some kind of magnetic field sensing device to identify who is coming and h...
xuehu855025 Sensor
FM1182e chip parameters
I'm debugging the fm1182e echo cancellation chip recently, and I'm confused by the various parameters in it. I asked the technical support, but they didn't know anything. I'm asking for help from my c...
jiemei6617 Embedded System
About the design of traffic lights (beginners' confusion)
Everyone, I am a beginner of single-chip microcomputer. I have a question about using single-chip microcomputer to control traffic lights. If there are three different display lights, R, G, and Y, at ...
gxlcgxlc MCU
GEMPLUS card reader
Has anyone bought a GEMPLUS SIM card reader? Where can I buy one? Or are there any card readers that have the same function as it and can view the file system in the SIM card? It would be best if it s...
A11111 Embedded System
When debugging MSP430 chip under IAR, the program cannot be downloaded normally.
[b][size=3]When debugging MSP430 chips under IAR, the program cannot be downloaded normally. What is the reason for this? Why does this interface appear all the time? [/size][/b]...
依仁 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 248  14  461  2735  2423  5  1  10  56  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号