High power-density, an industrial temperature range of -40°C to +85°C and extra features
like Remote-On-Off- control are just some of the characteristics of this converter, ideal for
highly sophisticated industrial designs. The RS series is available with isolation of 2kV or 3kV
by chosing option "/H2" or "/H3" in which case it is also ideal for medical applications which
additionally require EN-60601-1 certification.
Selection Guide
5V, 12V, 24V and 48V Input Types
Part Number
Input
Rated Output Output Current
Voltage Range Voltageat
Full Load
SIP8
(VDC)
(VDC)
(mA)
RS-xx3.3S (H2/H3)
4.5-9, 9-18
3.3
500
18-36, 36-72
RS-xx05S (H2/H3)
4.5-9, 9-18
5
400
18-36, 36-72
RS-xx09S (H2/H3)
4.5-9, 9-18
9
222
18-36, 36-72
RS-xx12S (H2/H3)
4.5-9, 9-18
12
166
18-36, 36-72
RS-xx15S (H2/H3)
4.5-9, 9-18
15
134
18-36, 36-72
RS-xx3.3D (H2/H3)
4.5-9, 9-18
±3.3
±250
18-36, 36-72
RS-xx05D (H2/H3)
4.5-9, 9-18
±5
±200
18-36, 36-72
RS-xx09D (H2/H3)
4.5-9, 9-18
±9
±111
18-36, 36-72
RS-xx12D (H2/H3)
4.5-9, 9-18
±12
±83
18-36, 36-72
RS-xx15D (H2/H3)
4.5-9, 9-18
±15
±67
18-36, 36-72
RS-xx3.3SZ (H2/H3)
9-36
3.3
500
18-72
RS-xx05SZ (H2/H3)
9-36
5
400
18-72
RS-xx09SZ (H2/H3)
9-36
9
222
18-72
RS-xx12SZ (H2/H3)
9-36
12
166
18-72
RS-xx15SZ (H2/H3)
9-36
15
134
18-72
RS-xx3.3DZ (H2/H3)
9-36
±3.3
±250
18-72
RS-xx05DZ (H2/H3)
9-36
±5
±200
18-72
RS-xx09DZ (H2/H3)
9-36
±9
±111
18-72
RS-xx12DZ (H2/H3)
9-36
±12
±83
18-72
RS-xx15DZ (H2/H3)
9-36
±15
±67
18-72
Efficiency
typ.
(%)
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
75
75
80
80
80
80
83
83
84
84
73
73
77
77
80
80
81
81
83
83
Max
Capacitive
Load
4700µF
1000µF
1000µF
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
4700µF
1000µF
1000µF
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
100
2 Watt
SIP8 Isolated
Single
&
Dual
Output
2011/65/EU
6/6
RoHS
EN-60950-1 Certified
EN-60601-1 Certified*
(*/H suffix )
RS
Derating-Graph
(Ambient Temperature)
RS-S(Z)_D(Z)
Output Power (%)
80
60
40
30
20
0
4:1
2:1
Safe Operating Area
-40
0
50 75 100
85
Operating Temperature °C
150
No suffix is standard isolation (1kVDC) e.g, RS-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS-0505S/H2, RS-0505DZ/H3
E-128
REV: 1/2014
2:1 Input
(RS-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
4:1 Input
(RS-SZ/DZ)
xx = 9-36Vin = 24
xx = 18-72Vin = 48
Refer to Application Notes
www.recom-power.com
ECONOLINE
DC/DC-Converter
Input Voltage Range
Output Accuracy
Line Voltage Regulation
Load Voltage Regulation
Minimum Load
Output Ripple and Noise (20MHz limited)
Switching Frequency
Efficiency at Full Load
Quiescent Current
Nominal input Voltage
(Standard, /H2 and /H3)
Isolation Voltage
Standard
/H2 Version
/H3 Version
Isolation Capacitance
Isolation Capacitance
Isolation Capacitance
Isolation Capacitance
Isolation Capacitance
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
Operating Temperature Range
(No Derating)
Storage Temperature Range
Relative Humidity
Package Weight
Packing Quantity
MTBF (+25°C)
(+85°C)
Certifications
2:1
4:1
Standard
/H2 and /H3
Standard
/H2 and /H3
Standard
/H2 and /H3
Full Load
RS-05xxS_D
RS-12xxS_D
RS-24xxS_D, SZ_DZ
RS-48xxS_D, SZ_DZ
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
2:1 Single
2:1 Single
2:1 Dual
2:1 Dual
4:1 Single/Dual
4:1 Single/Dual
20%-100% Load
RS-S_D(Z)
Series
2:1 and 4:1
±2% typ.
±0.5% max.
±0.5% max.
10%
(2)
50mVp-p max.
100kHz min. / 300kHz max.
See Selection Guide
40mA typ.
32mA typ.
25mA typ.
15mA typ.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
5pF min. / 30pF typ. / 60pF max.
200pF max.
30pF max
1GΩ min.
Continuous
–40°C to +85°C
–40°C to +75°C
–55°C to +125°C
95% RH
4.7g
22 pcs per Tube
using MIL-HDBK 217F
using MIL-HDBK 217F
Report: SPCLVD1212007
Report: MDD1205098-3 + RM1205098-3
1398 x 10
3
hours
210 x 10
3
hours
EN60950-1:2006 + 11:2009+A1:2010+A12:2011
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
Specifications
(measured at T
A
= 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified)
RS
}
Detailed Information see
Application Notes chapter "MTBF"
EN General Safety
EN Medical Safety
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1:
Note 2:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
www.recom-international.com
REV: 1/2014
E-129
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency / Load
100
80
60
40
RS-S_D(Z)
Series
RS-05xx types
2
1.70
1.5
RS-24xx
2412
Output Power (W)
2405
2415
2409
Efficiency %
1
0.5
0
20
0
0%
20%
40%
60%
80%
100%
4.5 5
6
7
8
9
Total Output current (%)
Input Voltage (V)
Package Style and Pinning (mm)
8 PIN SIP Package
9.20
Single Output
Dual Output
11.10
4.1
RECOM
RS-xxxx
****
0.50±0.05
RECOM
RS-xxxx
****
1 2 3
5 6 7 8
RECOM
RS-xxxxD
****
1 2 3
5 6 7 8
0.50±0.05
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin Connections
Recommended Footprint Details
2.54
1.0ø+0.15/0
Pin #
1
2
3
5
6
7
8
Single
–Vin
+Vin
CTRL
NC
+Vout
–Vout
NC*
Dual
–Vin
+Vin
CTRL
NC
+Vout
Com
–Vout
21.80
0.32
Bottom View
3.20
2.0
2.54
Top View
RS
NC = No Connection
NC* = NC, but no external Connection allowed.
Pin 8 (NC*)
This pin is used internally and must have no external connection.
Pin 5 (NC)
Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is ON.
There is no allowed low state for this pin.
Application Examples
ON/OFF CONTROL
V+
+Vin
V
IN
+
ON
OFF
V
IN
-
LEAVE OPEN
CTRL
+Vout
3
5~12
-Vin
1N4148
68
Ω
CTRL
-Vout
10K
FET.
V-
I
= 3V
O = 0.5V or GND
Remote ON/OFF
ON: open or high impendance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor
The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications.
The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property.
I am using Quartus 11.0, which does not have simulation capabilities. When I call Modelsim, I can only perform Gata level simulation, but not RTL level simulation. I am very confused. What is going on...
It is better to have more LEDs for running water lamps to make them feel better, so I add another string to make a total of 14 LEDs. TM1804 can be directly cascaded for expansion. The MCU uses a 1T 51...
The above figure is: the circuit diagram of differential input ADC conversion after differential acquisition voltage amplification
Vshunt is the normal voltage input, R1=R3 1K, R2=R4 5K, R6=R5 100Ω, V...
Hello everyone, I am debugging the LCD driver of A4 (ARM11) and I have encountered some problems. I don't know how to solve them. Please give me some advice. 1 When adjusting the backlight, the bright...
The jammer is a signal blocker, mainly composed of a chip and a radio transmitter. When the car owner presses the remote control lock button, the jammer interferes with the electronic lock receivin...[Details]
Amidst the wave of intelligent automotive transformation, advanced driver assistance is gradually emerging from cutting-edge technology into the mainstream, becoming a new frontier of industry comp...[Details]
In the summer of 2025, BlueOval SK, a joint venture between Ford and SK On, officially started production at its first battery factory in Kentucky.
According to the original plan, this w...[Details]
Electric vehicles' 12V batteries don't rely on a generator to power them. Only gasoline-powered vehicles rely on the engine to drive a generator to generate electricity while driving, which is used...[Details]
The practice of warming up a car originated with gasoline-powered vehicles. Warming up the engine allows it to enter a better working state and ensures good lubrication. This has become a habit for...[Details]
Charging is a familiar process for new energy vehicles, and as a source of battery energy, charging piles are crucial. New energy vehicle charging can be divided into fast charging and slow chargin...[Details]
Chinese characters are extensive and profound, and there are many different names for ESD tubes. How many of them do you know?
As far as I know, ESD diodes are currently known as ESD p...[Details]
During daily operation of an R-type power transformer, the voltage used varies as the equipment being used adjusts. This raises the question: can the transformer change voltage at this point? The a...[Details]
Inverter power supplies on the market can generally be divided into two categories: sine wave inverters and square wave inverters. Some engineers also like to categorize pure sine wave inverters as...[Details]
Lightweighting of automobiles is still a relatively unfamiliar term for automobiles. With the continuous improvement of environmental protection requirements, relevant regulations have also put for...[Details]
Traditionally, electrical energy is transmitted primarily through wires, requiring direct physical contact between the power source and the load. With the increasing number of electrical devices in...[Details]
The transition to SDVs (software-defined vehicles) involves more than just replacing parts; rather, it involves the organic connection of various elements, from internal vehicle systems to ext...[Details]
Shock absorbers, as the name implies, are responsible for cushioning and absorbing shocks in a car. So how much do you know about shock absorbers and how to replace them in electric cars?
...[Details]
System Principle
According to the average imbalance rate of the branch three-phase phase line load and the average value of the branch phase line current, the adjustment of the phase line load...[Details]
The BB-Black is a development platform based on the TI AM335X processor, manufactured and sold by Embest under license from BeagleBoard.org. The BB-Black boasts superior graphics performance among ...[Details]