EEWORLDEEWORLDEEWORLD

Part Number

Search

TM400-H

Description
high power general use insulated type
File Size65KB,4 Pages
ManufacturerPOWEREX
Websitehttp://www.pwrx.com/Home.aspx
Download Datasheet Compare View All

TM400-H Overview

high power general use insulated type

MITSUBISHI THYRISTOR MODULES
TM400DZ/CZ/PZ/UZ-M,-H,-24,-2H
HIGH POWER GENERAL USE
INSULATED TYPE
TM400DZ/CZ/PZ/UZ-M,-H,-24,-2H
I
T (AV)
V
RRM
Average on-state current ..........
400A
Repetitive peak reverse voltage
........
400/800/1200/1600V
V
DRM
Repetitive peak off-state voltage
........
400/800/1200/1600V
DOUBLE ARMS
Insulated Type
(DZ Type)
APPLICATION
DC motor control, NC equipment, AC motor control, Contactless switches,
Electric furnace temperature control, Light dimmers
OUTLINE DRAWING & CIRCUIT DIAGRAM
(DZ)
CR
1
K
1
K
2
G
2
K
2
Dimensions in mm
K
2
G
2
A
2
CR
2
K
1
G
1
A
1
K
1
K
2
A
2
A
1
60
50
36
16
26
36
G
1
K
1
(CZ)
3–φ6.5
CR
1
A
1
K
1
K
2
CR
2
A
2
K
1
G
1
K
2
G
2
24
23
35
24
44
24
35
80±
0.2
180
24
26
4–M8
80±
0.2
(PZ)
CR
1
Tab#110, t=0.5
9
A
1
K
1
K
2
CR
2
K
2
G
2
A
2
K
1
G
1
LABEL
36
50
(UZ)
CR
1
K
2
G
2
A
2
K
1
K
2
CR
2
K
1
G
1
9
(DZ Type)
A
1
(Bold line is connective bar.)
Feb.1999

TM400-H Related Products

TM400-H TM400DZ-H TM400-M TM400CZ TM400-24 TM400-2H
Description high power general use insulated type scr phse ctrl DL mod 800v 400a high power general use insulated type high power general use insulated type high power general use insulated type high power general use insulated type

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1849  2266  2304  1987  2771  38  46  47  40  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号