HX10-NP

Description
current transducer HX 05~10-NP
File Size147KB,2 Pages
ManufacturerLEM
Websitehttp://www.lem.com
Download Datasheet Compare View All

HX10-NP Overview

current transducer HX 05~10-NP

Current Transducer HX 05...10-NP
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
=
5 .. 10 A
Electrical data
Primary nominal
r.m.s. current
I
PN
(A)
Series
Parallel
Primary current
measuring range
I
P
(A)
Series
±
15
±
30
Parallel
Primary Conductor
Diameter x Turns
(mm)
Type
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
2 isolated primary windings
Isolation voltage 3000V
Low power consumption
Extended measuring range(3x
I
PN
)
Power supply from ±12V to ±15V
Material according to UL94-V0
± 5
± 10
V
OUT
R
OUT
R
L
V
C
I
C
V
d
± 10
± 20
± 30
± 60
0.7d
x
(6T+6T)
1.0d
x
(3T+3T)
HX 05-NP
HX 10-NP
V
kΩ
V
mA
kV
kV
V
e
Output voltage @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
±4
Output impedance
< 50
Load resistance
10
1)
Supply voltage (± 5 %)
± 15
Current consumption
< ± 20
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn
Primary to secondary
>3
Primary 1 to primary 2
>1
R.m.s. voltage for partial discharge extinction
at
10pC
1
Impulse withstand voltage, 1.2/50µs
6
Advantages
kV
kV
Low insection losses
Easy to mount with automatic
handling system
Small size and space saving
High immunity to external
interference.
Accuracy-Dynamic performance data
X
ε
L
V
OE
V
OH
V
OT
TC
ε
G
t
r
f
Accuracy @
I
PN
,
T
A
= 25°C (without offset)
Linearity (0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 3 x
I
PN
Thermal drift of
V
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of
I
P
Frequency bandwidth (-3 dB)
2)
<±1
<±1
< ± 40
< ± 15
max. ± 1.5
± 0.1
3
50
% of
I
PN
% of
I
PN
mV
mV
mV/K
%/K
µs
kHz
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
General data
T
A
T
S
m
Ambient operating temperature
- 25 .. + 85 °C
Ambient storage temperature
- 25 .. + 85 °C
Mass
8
g
Min. internal creepage distance/clearance
5.5
mm
Isolation material group
I
Standards
EN50178
1)
Notes : Also operate at ±12V power supplies, measuring range reduced to ±2.5x
I
PN
2)
Small signal only to avoid excessive heating of the magnetic core
011012/2
LEM Components
www.lem.com

HX10-NP Related Products

HX10-NP HX05-NP
Description current transducer HX 05~10-NP current transducer HX 05~10-NP

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 271  2686  1045  160  2598  6  55  22  4  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号