EEWORLDEEWORLDEEWORLD

Part Number

Search

AV100-125

Description
voltage transducer AV 100 series
File Size42KB,2 Pages
ManufacturerLEM
Websitehttp://www.lem.com
Download Datasheet Compare View All

AV100-125 Overview

voltage transducer AV 100 series

Voltage Transducer AV100 Series
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
V
PN
= 50...1500 V
Electrical data
Primary nominal
R.m.s or DC voltage
Primary Voltage R.m.s. voltage for AC
Type
1)
measuring range
isolation test
(50 Hz/1min)
V
PN
(V)
V
Pmax
(V)
V
d
(kV)
50
± 75
3.3
AV 100-50
125
± 187.5
3.3
AV 100-125
150
± 225
3.3
AV 100-150
250
± 375
3.3
AV 100-250
500
± 750
3.3
AV 100-500
750
± 1125
4.3
AV 100-750
1000
± 1500
5.5
AV 100-1000
1500
± 2250
6.5
AV 100-1500
Not measurable overload
2 x V
Pmax
(1s/h)
V
DC
Measuring resistance
R
M min
R
M max
@
V
C
=11.4V
0
47
@
V
C
=22.8V
0
184
Secondary nominal r.m.s. current
50
mA
Supply voltage (± 5 %)
DC ± 12 .. 24
V
Current consumption
50+I
S
mA
Max Common mode voltage
U
HT+
+ U
HT-
≤ 4.2
k V
DC
and
U
HT+
- U
HT-
≤
V
PMAX
R.m.s. voltage for partial discharge
1.1
2)
kV
3)
extinction @ 10pC
2.2
kV
Features
Insulated plastic case recognized
according to UL 94-V0.
Included primary resistor
Advantages
Low power
Excellent accuracy
Very good linearity
Low thermal drift
Low response time
High bandwidth
High immunity to external
interference
Low disturbance in common mode.
ˆ
V
P
R
M
I
SN
V
C
I
c
V
e
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Power supplies for welding
applications
.
Accuracy - Dynamic performance data
X
G
X
G
X
G
Overall Accuracy @
V
PN
,
T
A
= + 25°C
Overall Accuracy @
V
PN
,
T
A
= - 25 .. + 70°C
Overall Accuracy @
V
PN
,
T
A
= - 40 .. + 85°C
Linearity @
T
A
= 25°C
Offset current @
V
P
= 0,
T
A
= 25°C
Response time @ 10 % of
V
Pmax
Frequency bandwidth (- 3 dB)
± 0.7
%
± 1.5
%
± 1.7
%
< 0.1
%
± 0.15
mA
Between 10 and 13 µs
DC .. 13
kHz
ε
L
I
O
t
r
f
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
Standards
- 40 .. + 85
- 50 .. + 90
375
EN 50155
EN 50124-1
NFF16101/2
°C
°C
g
Notes :
1)
Between primary and secondary
2)
For models AV 100-50 to 750
3)
For models AV 100-1000 & AV 100-1500
030523/4
LEM Components

AV100-125 Related Products

AV100-125 AV100-1000 AV100-50 AV100-750 AV100-500 AV100-250 AV100 AV100-1500 AV100-150
Description voltage transducer AV 100 series voltage transducer AV 100 series voltage transducer AV 100 series voltage transducer AV 100 series voltage transducer AV 100 series voltage transducer AV 100 series voltage transducer AV 100 series voltage transducer AV 100 series voltage transducer AV 100 series
g_pKato->Log?
What does this statement mean? It is often used when testing wince drivers: g_pKato->Log(LOG_PASS, TEXT("Simple ReadWriteTest succeeded")); g_pKato does not have any relevant definition?...
chunhuaqiouhsi Embedded System
ADC10 multi-channel input of msp430g2553
[i=s]This post was last edited by Hot Ximixiu on 2020-12-1 22:05[/i]msp430g2553 has 8 external channels for input. The following program will complete the 3-way input to control the on and off of 3 LE...
火辣西米秀 Microcontroller MCU
【TI Recommended Course】#Texas Instruments Field Transmitter Output Interface/Fieldbus Solution#
//training.eeworld.com.cn/TI/show/course/5695...
54chenjq TI Technology Forum
About TI's TMS320dm355 development issues
I recently bought a new board for learning, but I have never been exposed to it before. If anyone knows, please give me some advice. Thank you......
lixs688 Embedded System
Help! ! Does anyone have a C language example for MAX505?
Help! ! Who has the (C language) routines for MAX505 and MAX118? My email address is: haidaomaolin@163.com Maolin would like to thank you all....
wtynyi Programming Basics
Angle measurement solution
[i=s]This post was last edited by paulhyde on 2014-9-15 04:03[/i]The best solution for angle measurement is: photoelectric encoder, choose 360P/R, angle measurement resolution is 1 degree, output dire...
gzmiaody Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1800  38  59  299  1061  37  1  2  7  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号