AAD600S
600 Watts
max
output power
Power Factor Correction
Single Output
Electrical Specifications
Input Voltage:
Input Current:
85-264 VAC, 47-63 Hz
<6.5A RMS @ 115 VAC @ full load
<3.5A RMS @ 230 VAC @ full load
9.0A RMS @ 85 VAC @ full load
<20A, pk @ 110 VAC, active soft start
<40A, pk @ 220 VAC, active soft start
(Active independant of cold or warm start)
>0.99 @ full load @ 230VAC input
Meets IEC1000-3-2
Meets CISPR 11 and 22 and FCC Part 15
Class B (conducted)
Internal AC line fuse; 250 VAC, 10A
Inrush Current:
Model
Switch Mode Power Supply
H.A.L.T.
TESTED
Highly
Accelerated
Life
Testing
Power Factor:
Harmonic Distortion:
EMI Filtering:
Input Protection:
Output Power:
Line Regulation:
Load Regulation:
PARD:
Hold-up Time:
Output Polarity:
Minimum Load:
Transient Response:
Output Rise Time:
Remote Sense:
Current Share:
Remote On/Off:
Up to 600W continuous
± 0.1%
±0.25%
<1% or 250mV
20MHz bandwidth
>16 ms @ full load
Output is floating
None
2% for 25% load change @ 1A/µs
<100 ms (10% to 90%)
Standard
Within 5%
Ground or TTL
LOW
= OFF
Open or TTL
HIGH
= ON
AC Power Fail:
TTL
LOW
logic “0” at least 2 ms before DC
output drops 5% (without signal jitter).
Open collector.
Open collector when output voltage is above
95% of rated
Square current limit; 105-130% of rated
Factory set, 125% ±5%
cycle AC to reset
Reverse current up to rated outputs
Auto off; auto reset upon cool down
Up to 92%
MIL-STD-HDBK 217E
200,000 hours @ 25°C, ground benign,
Highly Accelerated Life Testing
DC OK:
Overcurrent/Short Circuit:
Overvoltage Protection:
Reverse Voltage:
Thermal Protection:
Efficiency:
MTBF:
Available Voltage Outputs*
Voltage
Codes
Voltages
(Volts)
Continuous
Current
(Amps)
-4
-5
12
15
42
36
-6
-7
-8
24
28
36
23
20
16
-9
*
Consult factory for other voltages and OEM quantities.
Note: Standard models are shown
bold
48
12.5
PART # STRUCTURE:
MODEL
-
VOLTAGE CODE -
OPTION CODES
(See back)
-
V1
-
AAD600S
-
X
-
ABC....
Example: Part Number AAD600S-8-CF = 600W Power Factor Corrected, 36V @ 16A with sealed pots and overcurrent foldback
mode.
SEE
3rd PAGE FOR THE
AAD600S CODE TABLE AND AVAILABLE OPTIONS.
AAD600S
Options
(code)
DC OK Invert (U)
Metric Mounting (M)
OR-ing Diodes (O)
Droop Current Share (A)
Gold Plated Signal Connector (G)
Sealed Pots (C)
PF Invert (B)
Remote On/Off Invert (S)
Overcurrent Hiccup Mode (D)
Overcurrent Latch-off Mode (E)
Overcurrent Foldback Mode (F)
Standby Power (5VDC @ 1A) (P)**
**Voltage available as long as AC input is present
Model
Surge & ESD Test Levels
EN61000-4-5 Level 3
EN61000-4-2 Level 2
EN61000-3-2
EN61000-4-2 Level 3 (Air Only)
EN61000-4-4 Level 3
EN61000-4-11
Meets Class B conducted limits per
CISPR 11/22
and CFR 15 subpt B
Physical Specifications
Dimensions: (HxWxL)
Operating Temp:
1.59" x 4" x 9"
0 to 70°C; rated power to 50°C
derate linearly to 50% at 70°C.
5% to 90%, non-condensing
-50 to 85°C/20-90% RH
6,561' operating;
40,000' storage
IEC / EN / UL /
CSA 60950-1
CE
Declaration to Low Voltage Directive
2006/95/EC and
RoHS Directive 2011/65/EU
Relative Humidity:
Storage:
Altitude:
© Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice.
1
L
N
Item 40619 Rev A
TAMURA CORPORATION OF AMERICA
1040 South Andreasen Drive, STE. 100 Escondido, CA 92029-1951
(951) 699-1270 / Fax: (951) 676-9482
(800) 472-6624
www.tamuracorp.com
FM 32227
PRODUCT CODE TABLE
AAD600S Series Part Number Code Table
Standard Models
Tailored Models
Custom Models
AAD600S-X-YYYYYY
AAD600S-X-60ZZZ
AAD600S-61ZZZ
P/N Codes
DC Output
Voltage
Code
Output Voltage and Current
Codes
“X” Channel
(V1)
Volts
Amps
12.0
15.0
24.0
28.0
36.0
48.0
42.0
36.0
23.0
20.0
16.0
12.5
A
B
Standard Options
“Y” Code Description
4
5
6
7
8
9
Droop Current Share
PF Invert
C
D
E
F
G
M
O
P
S
U
Sealed pot
OCP Hicc-up Mode
OCP latch off mode
OCP fold back mode
Gold plated signal connector
Metric Mounting
OR-ing Diode
5Vdc, 1A Standby Output
Remote On/Off Invert
(Open is off)
DCOK Invert
Tailored Units (no safety changes: omit “X”
code
for non-standard output)
-------------------------
“60ZZZ” : “Z” – Factory
Assigned P/N
Harnesses Added,
Special test data …
ETC….
Custom Units
(safety critical changes)
-------------------------
“61ZZZ” : “Z” – Factory
Assigned P/N
ETC…..
Page 1 of 1
39296 Rev A2