Parameter NameAttribute value
package instruction,
Reach Compliance Codeunknown
Other featuresREMOTE SHUTDOWN
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
CertificationCE, TUV, UL
Efficiency (main output)84%
high61 mm
Maximum input voltage264 V
Minimum input voltage85 V
length190 mm
Maximum operating temperature71 °C
Minimum operating temperature-20 °C
Maximum output current18 A
Nominal output voltage36 V
ProtectOUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL
Ripple voltage (main output)0.05303 Vrms
Maximum total power output648 W
width120 mm
Base Number Matches1
AC-DC Power Supplies Enclosed Type
Ordering information
PBA/PBW
PBA/PBW
PBA300F
PB
1
2
A
3
300
4
F
5
-5
6
-O
R
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
1Series
name
2Single
output
3Output
wattage
4Universal
input
5Output
voltage
6Optional
*5
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F3 :Reverse air exhaust
type
F4 :Low speed fan
N1 :with DIN rail
Refer to instruction manual
7.1.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA300F-3R3
198
ACIN 100V 3.3V 60A
ACIN 200V
*
3
3.3V 60A
PBA300F-5
300
5V 60A
5V 60A
PBA300F-7R5
300
7.5V 40A
7.5V 40A
PBA300F-12
324
12V 27A
12V 27A
PBA300F-15
330
15V 22A
15V 22A
PBA300F-24
336
24V 14A
24V 14(16.5)A
PBA300F-36
324
36V 9A
36V 9A
PBA300F-48
336
48V 7A
48V 7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V
CURRENT[A]
ACIN 200V
*
3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
1
RIPPLE[mVp-p]
-20 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-20 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-20 to +50
C
DRIFT[mV]
*
2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
-
RC
INPUT-FG
OUTPUT
-
RC
-
AUX-FG
OUTPUT-RC
-
AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
PBA300F-3R3 PBA300F-5
PBA300F-7R5 PBA300F-12 PBA300F-15
PBA300F-24
PBA300F-36
AC85 - 264 1
f
or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option
*
4)
3typ
4.1typ
1.6typ
2typ
50/60 (47 - 63)
68typ
74typ
76typ
78typ
78typ
79typ
81typ
71typ
77typ
79typ
81typ
81typ
82typ
84typ
0.98typ (Io=100%)
0.95typ (Io=100%)
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
3.3
5
7.5
12
15
24
36
60
60
40
27
22
14
9
60
60
40
27
22
14(16.5)
9
20max
20max
36max
48max
60max
96max
144max
40max
40max
60max
100max
120max
150max
150max
80max
80max
120max
120max
120max
120max
150max
140max
140max
160max
160max
160max
160max
160max
120max
120max
150max
150max
150max
150max
200max
160max
160max
180max
180max
180max
180max
240max
40max
50max
75max
120max
150max
240max
360max
60max
75max
120max
180max
180max
290max
440max
12max
20max
30max
48max
60max
96max
144max
300typ(ACIN 100/200V, Io=100%)
*
Start-up time is 500ms typ for less than 1minute of applying input again from turning off
20typ (ACIN 100/200V, Io=100%)
2.64 - 3.96
3.96 - 6.00
5.25 - 8.25
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60
3.30 - 3.40
5.00 - 5.15
7.50 - 7.80
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44
Works over 105% of rated current or 101% of peak current and recovers automatically
4.3 - 6.3
6.5 - 8.0
9.0 - 11.6
14.4 - 18.6
18.0 - 23.3
28.8 - 37.2
43.2 - 54.0
LED (Green)
Provided
Provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-20 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2
*
6
102
X
42
X
170mm [4.02
X
1.65
X
6.69 inches] (without terminal block and screw) (W
X
H
X
D) /1.0kg max
Forced cooling (internal fan)
*5
Please contact us about safety approvals for the model with option.
*6
Please contact us about class C.
*
A sound may occur from power supply at pulse loading.
PBA300F-48
79typ
82typ
OUTPUT
48
7
7
192max
300max
150max
400max
200max
500max
480max
600max
192max
the input voltage.
38.40 - 56.00
48.00 - 49.92
57.6 - 80.0
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4
Derating is required.Consult us for details.
PBA/PBW-16
PBA/PBW-16
51 MCU loads DSP program
The MCU is C8051F410, and the DSP is TMS320C6745. The MCU is connected to SPI1 of DSP. I want to write a program to load the MCU program to the DSP. Does anyone have a similar program that I can use a...
wxr7891 51mcu
What books should I learn to study computer hardware?
I am a sophomore. After entering university, I have been learning more about software. Now I feel that I have reached a bottleneck. I lack knowledge about hardware. Moreover, the school offers too few...
anzx23 Embedded System
stm32 chip program programming problem. . . .
The STM32F103C8T6 chip was used to develop the RCU control program. 500 units were mass-produced, and more than 30 of them could not be burned into the program. . When using J-link to burn a program, ...
zhj101zhj stm32/stm8
[Award Ceremony] Grab the post, I contribute to the Xilinx Resource Center!
Event Link:[Surprise for grabbing the post] I contribute to the Xilinx Resource Center! (04.01-06.30) https://bbs.eeworld.com.cn/thread-255480-1-1.html During the activity, the password for the encryp...
EEWORLD社区 FPGA/CPLD
About lm3s811 two duty cycle pwm sequential output
The problem is this, I want to output 50% pwm for several milliseconds and then output 70% pwm, but why does the program I wrote not loop when running, 50% pwm and then 70% pwm in an infinite loop. If...
赵金良2013 ARM Technology
Microcontroller C programming and application examples.part4
Microcontroller C programming and application examples.part4...
20023974 DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1229  1978  1556  2130  114  25  40  32  43  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号