EEWORLDEEWORLDEEWORLD

Part Number

Search

PBW30F-15-E

Description
DC Power Cords IN MATING HARNESS PMC/MMC SERIES
CategoryPower/power management   
File Size527KB,7 Pages
ManufacturerCosel
Download Datasheet Parametric View All

PBW30F-15-E Online Shopping

Suppliers Part Number Price MOQ In stock  
PBW30F-15-E - - View Buy Now

PBW30F-15-E Overview

DC Power Cords IN MATING HARNESS PMC/MMC SERIES

PBW30F-15-E Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerCosel
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 115 V
Output Voltage-Channel 215 V
Number of Outputs2 Output
Output Power30 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 264 VAC/120 VDC to 350 VDC
Output Current-Channel 11 A
Output Current-Channel 21.4 A
Commercial/MedicalCommercial
Isolation Voltage3 kV
Mounting StyleChassis
Length103 mm
Width78 mm
Height34.5 mm
Input Frequency50 Hz/60 Hz
Load RegulationRegulated
Power - Convection30 W
Factory Pack Quantity35
Unit Weight11 oz
AC-DC Power Supplies Enclosed Type
Ordering information
PBA/PBW
PBA/PBW
PBW15F
PB
1
2
W
3
15
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-06-472
1Series
name
2Dual
output
3Output
wattage
4Universal
input
5Output
voltage
6Optional
*10
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBW15F-12
16.8
VOLTAGE[V]
*
6
t
12 ( +24 )
CURRENT1[A] 0.7
CURRENT2[A]
*
5
1.4
*
5
PBW15F-15
15.0
t
15 ( +30 )
0.5
1.0
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT1[A]
CURRENT2[A]
*
5
*
9
LINE REGULATION[mV]
*
11
*
3
LOAD REGULATION 1[mV]
*
11
*
4
LOAD REGULATION 2[mV]
*
11
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
DRIFT[mV]
*
2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
PBW15F-12
PBW15F-15
AC85 - 264 1
f
or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
8)
0.40typ (CURRENT1)
0.20typ (CURRENT1)
50/60 (47 - 440) or DC
74typ (CURRENT1)
78typ (CURRENT1)
77typ (CURRENT1)
80typ (CURRENT1)
15typ (CURRENT1) (At cold start)
30typ (CURRENT1) (At cold start)
0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
/ ( +30V reference number )
/ ( +24V reference number )
t
12
t
15
0.7
/ 0.7
0.5
/ 0.5
1.4
/-
1.0
/-
60max
/ 96max
60max
/ 96max
600max
/ 150max
600max
/ 150max
750max
/-
750max
/-
120max
/ 240max
120max
/ 240max
160max
/ 320max
160max
/ 320max
150max
/ 300max
150max
/ 300max
180max
/ 360max
180max
/ 360max
120max
150max
150max
180max
48max
60max
200typ(ACIN 100V, Io=100%)
*
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
9.60 - 13.2 (+V and -V are simultaneously adjusted)
13.2 - 16.5 (+V and -V are simultaneously adjusted)
11.5 - 12.5 (+V and -V CURRENT1)
14.4 - 15.6 (+V and -V CURRENT1)
Works over 105% of rated current and recovers automatically
16.8 - 24.0
20.0 - 29.0
LED (Green)
None
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
-10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Not built-in to active filter
*
7)
*
12
31
X
78
X
85mm [1.22
X
3.07
X
3.35 inches] (without terminal block) (W
X
H
X
D) / 200g max (with cover : 235g max)
Convection
side is fixed.
*5
The sum of +power -power must be less than output power.
*6
t12,t15
can be used as +24 and +30.
*7
When two or more units are used,they may not comply with
the harmonic attenuator. Please contact us for details.
*8
Derating is required.
*9
Figures to rated current 1.
*10
Please contact us about safety approvals for the model with
option.
*11
Please contact us about dynamic load and input response.
*12
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
Measured by 20MHz oscilloscope or Ripple-Noise
meter(equivalent to KEISOKU-GIKEN : RM101).
*2
Drift is the change in DC output for an eight hour period
after a half-hour warm-up at 25C.
*3
Figures for 0 to rated current 1.The current not measured
side is fixed.
*4
Figures for 0 to rated current 2.The current not measured
PBA/PBW-26
PBA/PBW-26
Compatible with Series 2600 SourceMeter instrument program commands
One aspect of the cost of implementing new test equipment involves switching from an existing, stable software program to support a new product.2600AWhen you purchase a Series 2600 SourceMeter instrum...
Jack_ma Test/Measurement
A little improvement on the invitation of 10 new friends to join the event
When we recommended friends to join EEORLD, we found that we could only do so by copying the website link or by typing many friends' email addresses into the designated area. It was really tiring. I t...
673652096 Suggestions & Announcements
Top 10 Reasons to Choose Windows CE
[b]What is Windows CE? [/b] Windows CE is a strategically important operating system. It has the characteristics of the Windows operating system, supporting 32-bit virtual memory mechanism, on-demand ...
spaceaky Embedded System
Dear experts, please help, as shown in the picture
Dear experts, please help, as shown in the picture...
tkyl01 Analog electronics
Below is me counting from 0 to 1000, but why is it wrong when I count to 6? Where did I go wrong?
Below is me counting from 0 to 1000, but why I got it wrong when I got to 6? Where did I go wrong? I am a novice and my level is not high.#includereg51.h #define uint unsigned int #define uchar unsign...
ylf175300 51mcu
I hope you can recommend a shell...
Suddenly I thought that this MP3 player should have a good shell. Does anyone have any recommendations? Thanks in advance. . ....
zhaojun_xf MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1383  2205  1313  2389  1783  28  45  27  49  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号