EEWORLDEEWORLDEEWORLD

Part Number

Search

PMA100F-3R3-J1

CategoryPower/power management   
File Size613KB,9 Pages
ManufacturerCosel
Download Datasheet Parametric View All

PMA100F-3R3-J1 Online Shopping

Suppliers Part Number Price MOQ In stock  
PMA100F-3R3-J1 - - View Buy Now

PMA100F-3R3-J1 Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerCosel
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 13.3 V
Number of Outputs1 Output
Output Power66 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 264 VAC
Output Current-Channel 120 A
Commercial/MedicalCommercial
Isolation Voltage3 kV
Mounting StyleChassis
Length168 mm
Width34 mm
Height93 mm
Input Frequency50 Hz/60 Hz
Load RegulationRegulated
Factory Pack Quantity25
Unit Weight1.378 lbs
AC-DC Power Supplies Medical Type
Ordering information
PMA15F
PM
1
2
A
3
15
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAM-04-000
Low leakage current type : NAM series
*
The EMI/EMC Filter is recommended
to connect with several devices.
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
*5
T : Vertical terminal block
T1 : Horizontal terminal block
N : with Cover
J1 : VH(J.S.T.)connector type
Horizontal terminal block
(option : -T1)
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
Vertical terminal block
(option : -T)
Standard type
with Cover
(option : -N)
PMA15F-12
15.6
12V 1.3A
PMA15F-15
15
15V 1A
Specification is changed at
option, refer to Instruction
Manual.
PMA15F-3R3
9.9
3.3V 3A
PMA15F-5
15
5V 3A
PMA15F-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C
RIPPLE[mVp-p]
*1
-10 - 0C
0 to +50C
RIPPLE NOISE[mVp-p]
*1
-10 - 0C
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
PMA15F-3R3
PMA15F-5
PMA15F-12
PMA15F-15
PMA15F-24
AC85 - 264 1f (Refer to the Instruction Manual 1.1 and 3.2)
*3
0.30typ (Io=100%)
0.40typ (Io=100%)
0.15typ (Io=100%)
0.20typ (Io=100%)
50 / 60 (47 - 440)
76typ
76typ
66typ
70typ
74typ
79typ
79typ
67typ
74typ
78typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.05/0.10max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)
3.3
5
12
15
24
3.0
3.0
1.3
1.0
0.7
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
200typ (ACIN 100V, Io=100%)
*Start-up
time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 to 3.60
4.50 to 5.50
10.00 to 13.20
13.20 to 18.00
19.20 to 27.00
3.30 to 3.40
5.00 to 5.15
12.00 to 12.48
15.00 to 15.60
24.00 to 24.96
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
15.00 to 18.00
20.00 to 25.00
30.00 to 37.00
LED (Green)
Not provided
AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1
Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2
(Class A)
*6
(Not built-in to active filter
*4)
31X78X103mm [1.22X3.07X4.06 inches] (WXHXD) / 230g max (with cover : 265g max)
Convection
*5
*6
*
*
*
Please contact us about safety approvals for the model with option.
Please contact us about another class.
Parallel operation with other model is not possible.
Derating is required when operated with cover.
A sound may occur from power supply at peak loading.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
PMA
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
Derating is required.
When two or more units are used, they may not comply with the harmonic attenuator. Please
contact us for details.
PMA-2

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2332  1245  1955  2028  2819  47  26  40  41  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号