Industrial and process control, distributed power, medical, ATE, communications,
defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to -IN voltage
PC to -IN voltage
PR to -IN voltage
SC to -OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +53
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V24C12T100BL2
24C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
V
OUT
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
B
Output Power
P
OUT
75W, 50W
125W, 100W, 50W
100W
150W, 100W, 50W
150W, 100W, 50W
150W,100W, 50W
150W, 100W, 50W
100W, 50W
150W, 100W, 50W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
24V Micro Family
Page 1 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Modules will operate to 16V
IN
after startup at >17.9V.
Below 18V, available power is reduced to 75% of max
rating.
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% /°C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Micro Family
Page 2 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20 ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30
Ω,
<30 pF
PC current = 1.0 mA
PC voltage = 5.5 V
Switch must be able to sink
≥4
mA. See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
24V Micro Family
Page 3 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 75W (e.g. S24C3V3C75BL, V24C3V3C75BL)
Parameter
Min
84.6
80.0
4.14
Efficiency
S24C3V3C75BL (enhanced efficiency)
V24C3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Typ
86.2
81.6
140
4.3
4
±0.02
26.1
26.1
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
175
4.46
6
±0.4
22.72
30.7
30.7
mV
Volts
Watts
%
Amps
Amps
Amps
3.3V
OUT
, 50W (e.g. S24C3V3C50BL, V24C3V3C50BL)
Parameter
Efficiency
S24C3V3C50BL (enhanced efficiency)
V24C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.6
75.0
4.14
Typ
84.0
79.2
240
4.3
1.6
±0.02
17.5
17.5
Max
Unit
%
300
4.46
3
±0.2
15.15
20.6
20.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 125W (e.g. S24C5C125BL, V24C5C125BL)
Parameter
Efficiency
S24C5C125BL (enhanced efficiency)
V24C5C125BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
83.0
6.0
Typ
86.5
84.5
150
6.25
4.3
±0.02
28.8
28.8
Max
Unit
%
188
6.5
5.3
±0.2
25.0
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p Nominal input full load 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250mV
0.0
25.5
17.5
5V
OUT
, 100W (e.g. S24C5C100BL, V24C5C100BL)
Parameter
Efficiency
S24C5C100BL (enhanced efficiency)
V24C5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.9
84.0
6.03
Typ
87.4
85.7
100
6.25
3.2
±0.02
23
23
Max
Unit
%
125
6.47
4.8
±0.2
20
27
27
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
2
24V Micro Family
Page 4 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 50W (e.g. S24C5C50BL, V24C5C50BL)
Parameter
Efficiency
S24C5C50BL (enhanced efficiency)
V24C5C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.5
83.0
6.03
Typ
87.8
84.5
80
6.25
1.3
±0.02
11.5
11.5
Max
Unit
%
100
6.47
2.1
±0.2
10
13.5
13.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
2
8V
OUT
, 100W (e.g. S24C8C100BL, V24C8C100BL)
Parameter
Efficiency
S24C8C100BL (enhanced efficiency)
V24C8C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
85.0
9.36
Typ
89.0
86.4
145
9.7
3
±0.02
14.4
14.4
Max
Unit
%
182
10.1
3.4
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 150W (e.g. S24C12C150BL, V24C12C150BL)
Parameter
Efficiency
S24C12C150BL (enhanced efficiency)
V24C12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.0
87.5
13.8
Typ
89.5
88.8
170
14.3
3.7
±0.02
14.4
14.4
Max
Unit
%
212
14.8
4.5
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p Nominal input full load 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.8
8.8
12V
OUT
, 100W (e.g. S24C12C100BL, V24C12C100BL)
Parameter
Efficiency
S24C12C100BL (enhanced efficiency)
V24C12C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.7
87.0
13.7
Typ
90.2
88.4
209
14.3
4.4
±0.02
9.59
9.59
Max
Unit
%
262
14.9
6.1
±0.2
8.33
10.9
10.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I would like to ask you, why do we need to configure these channels in PCFG3:PCFG0 of ADCON1 when CHS2:CHS0 of ADCON0 has already selected the AD channel? I feel that this is a bit redundant. It just ...
1. IO input design skills
01: Resistors or capacitors should be reserved on the lines that are prone to ESD intrusion, such as key input ports. If necessary, add components to enhance the system's abi...
[font=宋体][size=3] [/size][/font][font=Tahoma][size=3]I wanted to write a post about LM22676, but when I saw this event, I decided to take this as the theme and participate in the event. . . . [/size][...
There is a relatively detailed explanation about the clock system of MSP430 in the data sheet.This data comes from the data sheet of MSP430F5438A. ACLK: Auxiliary clock, can use 32KHz watch crystal, h...
1. Introduction
Since the 1980s, with the continuous development of automotive electronic technology, there are more and more electronic control units in automobiles, such as electronic fuel i...[Details]
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
Investment in
the
medical device
industry has been on the rise in recent years. In the past two years, venture capital for medical devices has almost doubled, reaching $4 billion in 2007. Fr...[Details]
Recently, news came from the certification department that the photovoltaic grid-connected inverter of Samil New Energy Co., Ltd. (hereinafter referred to as "Samil New Energy") has once again obta...[Details]
Liquid crystal display (LCD) panels have a wide range of applications, from small portable electronic devices to large fixed devices, including digital cameras, laptops, personal data assistants, d...[Details]
0 Introduction
There are many types of sensors, and the working principles, measurement targets and measurement environments of different types of sensors vary greatly. The corresponding detection s...[Details]
When the so-called "copycat phones" that flood the domestic mobile phone market move towards large screens, stereo amplifiers, touch controls, and even GPS navigation and mobile TV, the homogeneity...[Details]
The demand for improved healthcare environments is endless, so medical imaging equipment with higher resolution is needed to better observe the human body. High resolution brings problems with sign...[Details]
Battery clamps, commonly known as battery connectors, come in two sizes depending on the thickness of the battery terminals. One is the battery clamp used on thick terminals, with a positive termin...[Details]
Electrostatic coupling and interference occur when a charged object is close to the input of the circuit being measured. At low impedance, the effects of interference are not noticeable because th...[Details]
1 Introduction
Power supply ripple will interfere with the normal operation of electronic equipment, causing malfunctions such as computer crashes, data processing errors and control system fa...[Details]
0 Introduction
Pneumatic
artificial muscle,
also known as pneumatic muscle actuator (PMA), began to be studied in the 1950s. In recent years, it has been widely studied and applied ...[Details]
AUTOSAR is a hierarchical architecture for automotive electronic embedded software jointly launched by global automotive OEMs and suppliers. The hierarchical architecture consists of a microcontrol...[Details]