Preventa
™
XUSL Light Curtains
Catalog
File 9007
06
CONTENTS
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page
Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
XUSLP Type 4 Body Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
XUSLN Type 2 Hand Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
XUSL Light Curtain Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Building a New Electric World
2
©
2006 Schneider Electric All Rights Reserved
07/2006
Preventa™ XUSL Light Curtains
Selection
Preventa XUSL Light Curtains: Selection
Applications
Functions
Device
Packaging, conveyor systems, materials handling, warehousing, stocking, etc.
Body protection (300, 400, 500 and 600 mm)
Safety light curtains, type 4
1 to 6 beam light curtains with infrared
transmission (1 transmitter-receiver pair)
Hand protection (30 mm)
Safety light curtains, type 2
Multi-beam light curtains with infrared
transmission (1 transmitter-receiver pair)
Products
Conformity to
standards
Machine Assemblies
Product certifications
Type of ESPE
Degree of protection
Dimensions (W x D)
Protected height
(min/max)
Conforming to EN 999
ANSI/RIA R15.06, ANSI B11:19-1990, OSHA
1910.217(C), OSHA 1910.212, type 4 (ESPE)
conforming to IEC 61496-1 and 2
IEC 61496-1 and IEC 61496-2 type 2 (ESPE)
Machinery directive 98/37/EC, Work equipment Machinery directive 98/37/EC, Work equipment
directive 89/655/EEC and EMC directive 89/336/ directive 89/655/EEC and EMC directive 89/336/
EEC
EEC
CE, TUV, UL, CSA
Type 4
IP 65
2.05 x 2.17 in. (52 mm x 55 mm)
29.53 to 70.87 in. (750 to 1800 mm)
(1 to 6 light beams)
2.6 to 65.6 ft. (0.8 to 20 m) or 2.6 to 230 ft
(0.8 to 70 m) depending on configuration
2.6 to 25.6 ft. (0.8 to 8 m) for light curtains with
passive receiver
< 16 to < 24 ms depending on light beam coding
selected
CE, TUV. UL, CSA
Type 2
IP 65
1.12 x 1.26 in. (28.5 x 32 mm)
5.91 to 59.06 in. (150 to 1500 mm)
(hand protection)
Range (min/max)
0.98 to 49.21 ft (0.3 to 15 m)
Response time
14 to 24 ms
2 solid-state PNP outputs (N.O.)
c
24 Vdc,
≤
500 mA
Short-circuit protection
1 x 100 mA,
c
24 Vdc PNP alarm output
Functions integrated in the light curtain:
•
automatic or manual start depending on
version
Contacts
Safety
Auxiliary
2 solid-state PNP outputs (N.O.)
c
24 Vdc,
≤
650 mA
Short-circuit protection
1 solid-state 100 mA,
c
24 Vdc PNP output
Functions integrated in the light curtain:
•
Auto/Manual start and manual 1
st
cycle,
•
EDM (external devices monitoring),
•
test input,
•
3 light beam codings available,
Muting via external module
c
24 Vdc ± 20%, 2 A
XUSLPpppp
4
Main functions
“Muting” function
(inhibition of the light curtain “detection”
function)
Supply voltage
Product type
Page number
Muting via external module
c
24 Vdc ± 20%, 2 A
XUSLNGSCpppp, XUSLNGSDpppp
12
07/2006
©
2006 Schneider Electric All Rights Reserved
3
Preventa™ XUSLP Light Curtains
Technical Data
Preventa XUSLP Light Curtains: Technical Data
Light curtain type
XUSLPpppp
Conformity approvals
Conformity to standards
Certifications
European directives
ANSI/RIA R15.06, ANSI B11:19-1990, OSHA 1910.217(C), OSHA 1910.212, IEC 61496-1-2 for type 4
ESPE
e,
TUV, UL, CSA
Machinery directive 98/37/EC, Work equipment directive 89/655/EEC and EMC directive 89/336 EEC
Environment
Ambient air temperature
Relative humidity
Degree of protection
Shock and vibration resistance
Materials
Mounting
Conforming to IEC 61496-1
Operating
For storage
+ 32 to + 131 °F (0 to + 55 °C)
-13 to +167 °F (- 25 to+ 75 °C)
95% maximum, without condensation
IP 65
Shock resistance: 10 gn, impulse 16 ms,
Vibration resistance: 10…55 Hz, amplitude: 0.014 ± 0.0020 in. (0.35 ± 0.05 mm)
Casing: aluminium with electrostatically applied red (RAL 3000) polyester paint finish; end caps: 20%
fiberglass impregnated polycarbonate. Front face: acrylic.
End brackets (included)
Optical characteristics
Minimum object sensitivity (MOS)
Nominal sensing range (Sn)
Protected height
Effective aperture angle (EAA)
Light source
Resistance to ambient light
11.8, 15.8, 19.7, and 23.6 in. (300, 400, 500, and 600 m) and single beam (Body protection)
2.6 - 65.6 ft (0.8 - 20 m) or 2.6 - 230 ft (0.8 - 70 m) depending on configuration and 2.6 - 25.6 ft
(0.8 - 8 m) for light curtains with passive receiver.
Depending on number of light beams
2.5° at 9.8 ft (3 m)
GaAIAs LED, 850 nm
Conforming to IEC/EN 61496-2
Electrical characteristics
Response time
ms
< 16 to < 24 depending on light beam coding selected
c
24 Vdc ± 20% 2 A conforming to IEC 61496 and IEC 60204-1
Power supply
Transmitter
Receiver
Maximum current consumption
(no-load)
Resistance to interference
Safety outputs OSSD (Output Signal Switching Devices)
Auxiliary output
Monitoring activation of output switching devices (MPCE/EDM)
Signalling
Transmitter
Receiver
Transmitter
Receiver
Transmitter/receiver pre-wired
connector
Transmitter/receiver
Transmitter
Receiver
mA
A
mA
mA
100
1.6 (with maximum load)
100
300
Conforming to EN 61496-1
2 solid-state PNP (N.O.) outputs
≤
650 mA,
c
24 Vdc (Short-circuit protected)
1 solid-state output 100 mA,
c
24 Vdc, PNP
50 mA,
c
24 Vdc
1 LED (power supply)
3 LEDs (stop, run, interlock) and a 2-digit display for diagnostics
M12, 5-pin, male connector or terminal block
M12, 8-pin, male connector or terminal block
22 awg (0.32 mm
2)
0.016
Ω
per foot (0.055
Ω
per meter) for 22 awg (0.32 mm
2
) c.s.a. cable
Pre-wired connectors with cable lengths of 16.4, 32.8, 49.2 and 98.4 ft (5, 10, 15 and 30 m) are available
separately. The maximum cable length is 394 ft (120 m), depending on the load current and power supply.
Connections
(1)
Cable guage
Cable resistance
Cable lengths
Functions
Start:
Auto/Manual, manual 1
st
cycle,
Monitoring of external switching devices (EDM: External Devices Monitoring),
Test (MTS: Monitoring Test Signal) for XUS LPZ only,
Alignment aid by display of each light beam broken,
Display of operating modes and alarm by LEDs and 2-digit display.
Selection of Auto/Manual, relay monitoring, alarm or auxiliary output functions, light beam coding and
selection of sensing distance using configuration switches.
Monitoring of the function (open or closed) as well as the response time of the power components.
Configurable using configuration switches.
Instigates the stop instruction of the light curtain by opening the contact (simulated intrusion)
Possible with external module
XPSLMS1150.
(1)
Pre-wired female connectors to be ordered separately, see page 7.
Functions
Monitoring of external switching devices
(EDM = External Devices Monitoring)
“Test” function (MTS)
“Muting” function
Ordering Information . . . . . . . 5 - 7
Dimensions. . . . . . . . . . . . . . 8 - 9
Wiring Diagrams . . . . . . . .10 - 11
4
©
2006 Schneider Electric All Rights Reserved
07/2006
Preventa™ XUSLP Light Curtains
Ordering Information
Preventa XUSLP Light Curtains: Ordering Information
Transmitter-receiver pairs for body protection
(1)
Protection height 11.8, 15.8, 19.7, and 23.6 in. (300, 400, 500, and 600 mm) and single beam.
Sensing distance 2.6 - 65.6 ft (0.8 - 20 m) or 2.6 - 230 ft (0.8 - 70 m) (depending on configuration)
-- 2 PNP safety outputs
Response time
Light beam coding
A
ms
–
19.69 (500)
23.62 (600)
< 24
< 24
< 24
< 24
< 24
< 24
< 24
< 24
B
ms
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
C
ms
< 16
< 16
< 16
< 16
< 16
< 16
< 16
< 16
1
2
2
3
3
4
5
6
PNP
PNP
PNP
PNP
PNP
PNP
PNP
PNP
XUSLPZ1AM
XUSLPZ2A0500M
XUSLPZ2A0600M
XUSLPZ3A0400M
XUSLPZ3A0500M
XUSLPZ4A0300M
XUSLPZ5A0300M
XUSLPZ6A0300M
9.9 (4.500)
13.9 (6.300)
14.8 (6.700)
15.9 (7.200)
19.0 (8.600)
18.1 (8.200)
21.0 (9.500)
22.9 (10.400)
Protection height
in. (mm)
Number of light
beams
Auxiliary output
Catalog number
(2)
Weight
lb. (kg)
XUSLPZ1AM
15.75 (400)
19.69 (500)
11.81 (300)
11.81 (300)
11.81 (300)
(1)
(2)
Supplied with 2 sets of 2 brackets with mounting hardware and a user guide with certificate of conformity.
Pre-wired female connectors to be ordered separately, see page 7.
To order a receiver only, add the letter
R
to the end of the reference for the corresponding transmitter-receiver pair.
Example: reference XUSLPZ2A0600M becomes
XUSLPZ2A0600MR
for the receiver only.
To order a transmitter only, add the letter
T
to the end of the reference for the corresponding transmitter-receiver pair.
Example: reference XUSLPZ2A0600M becomes
XUSLPZ2A0600MT
for the transmitter only.
Transmitter-receiver pairs for body protection, with passive receiver
(1)
XUSLPZ3AppppM
The
XUSLPB
system integrates the receiver and transmitter into one assembly, the transceiver, which is mated with a passive reflector unit. The passive
unit does not require electrical connections.
Protection height 19.7 and 23.6 in. (500 and 600 mm). Sensing distance 2.6 to 26.3 ft (0.8 to 8 m)
-- 2 PNP safety outputs
Response time
Light beam coding
A
ms
19.69 (500)
23.62 (600)
(1)
(2)
< 24
< 24
B
ms
< 20
< 20
C
ms
< 16
< 16
2
2
PNP
PNP
XUSLPB2A0500M
XUSLPB2A0600M
13.9 (6.300)
14.8 (6.700)
Protection height
in. (mm)
Number of light
beams
Auxiliary output
Catalog number
(2)
Weight
lb (kg)
Supplied with 2 sets of 2 brackets with mounting hardware and a user guide with certificate of conformity.
Pre-wired female connectors to be ordered separately, see page 7.
To order a receiver only, add the letter
R
to the end of the reference for the corresponding transmitter-receiver pair.
Example: reference XUSLPB2A0500M becomes
XUSLPB2A0500MR
for the receiver only.
To order a transmitter only, add the letter
T
to the end of the reference for the corresponding transmitter-receiver pair.
Example: reference XUSLPB2A0600M becomes
XUSLPB2A0600MT
for the transmitter only.
XUSLPB2pp
Æ
File E198201
NIPF ESPE
Class 219153
®
Technical Data . . . . . . . . . . . . . . 4
Dimensions. . . . . . . . . . . . . . 8 - 9
Wiring Diagrams . . . . . . . .10 - 11
07/2006
©
2006 Schneider Electric All Rights Reserved
5