Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC1R5-1203Sx-E CC1R5-1205Sx-E
CC1R5-1212Sx-E
CC1R5-1212Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1)
%
73
78
82
81
Current (typ)
(*1) A
0.151
0.160
0.152
0.154
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40° to +50°
C
C)
Max Power Total Regulation (max) (*4)
%
3
±
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4 - 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Operating Ambient Humidity
Environment
Storage Ambient Humidity
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
2
CC1R5-E
3
MODEL CC1R5-2403Sx-E CC1R5-2405Sx-E
CC1R5-2412Sx-E
CC1R5-2412Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1)
%
72
77
81
79
Current (typ)
(*1) A
0.076
0.081
0.077
0.079
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40° to +50°
C
C)
Max Power Total Regulation (max) (*4)
%
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Environment
Storage Ambient Humidity
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC1R5-4803Sx-E CC1R5-4805Sx-E
CC1R5-4812Sx-E
CC1R5-4812Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC48
Voltage Range
V
DC36-76
Input
Efficiency (typ)
(*1)
%
70
76
80
79
Current (typ)
(*1) A
0.039
0.041
0.039
0.040
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40° to +50°
C
C)
Max Power Total Regulation (max) (*4)
%
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Operating Ambient Humidity
Environment
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
CC1R5-E
Outline Drawing
CC1R5-xxxxxF-E (DIP type)
Shape/Dimensions
8.5max.
4
16.6±0.2
Recommended measurements for
mounting board
4.0
14.605
2.92
Outer shape of
product
16.51
2.54
(3.22)
0.5
1.905
a
3
2
7.62
12.7
1.905
b
4
5
a
2.7
13.08
12.7
7-ø1.0 (land diameter ø2.0)
2-ø1.5 (land diameter ø2.5)
3.5
2.54 5.08 2.54
16.51
1.0
b
0.5
7-0.3×0.6
1
b
6
7
a
2.7
CC1R5-xxxxxR-E (SMD type)
Shape/Dimensions
8.8max.
(3.22)
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
16.6±0.2
Recommended measurements for
mounting board
4.0
(3.22)
Outer shape of
product
2.54 5.08 2.54
3.2
3.5
t=0.3
10.16
7.62
t=0.3
(13.38)
16.51
Coplanarity: 0.1 or lower
1.8
19.81
1.8
2.54
(3.22)
3.2
15.6
22.0
2
7.62
5
7-0.3×0.6
6
7
(3.22)
1
2.54 5.08 2.54
3
4
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
Connection diagram
CC1R5-xxxxSx-E
+Vin
1
7
6
RC
–Vin
5
2
3
+Vout
Terminal connections
No.1
No.2
No.3
No.4
No.5
No.6
No.7
+Vin
RC
–Vin
NC
–Vout
TRM
+Vout
Load
CC1R5-xxxxDx-E
+Vin
1
7
6
RC
–Vin
5
2
3
4
+Vout
Terminal connections
No.1
No.2
No.3
No.4
No.5
No.6
No.7
+Vin
RC
–Vin
–Vout
Common out
TRM
+Vout
Load
TRM
–Vout
TRM
COM
–Vout
4 NC
Derating Curve
100
Output power (%)
80
60
40
20
Natural air cooling
a
b
a:
0.5m/s
(100LFM)
b:
1m/s
(200LFM)
Ambient temperature (°
C)
0
-40 -20 0 20 40 60 80 100
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
2.54 5.08 2.54
10.16
7.62
1.2
Load
(DIP/SMD)
CC3-E
CC3-E Specifications
MODEL CC3-0503Sx-E
CC3-0505Sx-E
CC3-0512Sx-E
CC3-0512Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC5.0
Voltage Range
V
DC4.5-9.0
Input
Efficiency (typ)
(*1)
%
73
77
82
81
Current (typ)
(*1) A
0.723
0.779
0.732
0.741
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2)
2.64
3
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4)
%
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
%
RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
%
RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Vibration
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC3-1203Sx-E
CC3-1205Sx-E
CC3-1212Sx-E
CC3-1212Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1)
%
74
79
82
81
Current (typ)
(*1) A
0.297
0.316
0.305
0.309
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2) W
2.64
3
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4)
%
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Operating Ambient Humidity
Environment
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
Please give me some advice. I use msp430+ov7670 to make a black and white image test program, but the image has not come out. I don't know what the problem is....
[i=s] This post was last edited by gs001588 on 2018-1-26 03:10 [/i] [align=center][font=宋体][size=3]STEVAL-IDB007V1 ADC Test 1 [/size][/font][/align] [align=left][font=宋体][size=3] This evaluation and c...
Some people boast that even if the software they wrote is decrypted by others, the pass rate of burning with the decrypted code is only 80% (and this pass rate can be determined when writing the progr...
[i=s]This post was last edited by dontium on 2015-1-23 11:11[/i] [align=left][font=宋体][size=4] Chapter 5 introduces the introduction to noise measurement and introduces three instruments for measuring...
This is a problem I encountered when observing the RTL view when doing an experiment on digital tubes. I don't know what the red symbols in the picture mean? Please explain it to me....
At present, the development of wireless power supply technology for electric vehicles (EVs) is becoming more and more active. In 2012, Volvo of Sweden established Volvo Technology Japan in Tokyo as...[Details]
1. Introduction
RFID (radio frequency identification) is a non-contact automatic identification technology that emerged in the 1990s. It uses the characteristics of radio frequency signal prop...[Details]
Automotive applications are particularly sensitive to EMI events, which are unavoidable in a noisy electrical environment consisting of a central battery, bundled wiring harnesses, various inductiv...[Details]
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
In order to highlight the concept of "energy saving and environmental protection" of intelligent buildings, solar street lights are designed for intelligent communities. The inclination and capacit...[Details]
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The way to reduce costs is
① Use the Bluetooth data transmission function of mobile ph...[Details]
Electronic systems are located at different points on the automotive power bus and therefore often need to operate under very stringent power requirements. These include load dump, cold crank, very lo...[Details]
Although it is relatively easy to check the stability of a simple amplifier at lower frequencies, it may be much more difficult to evaluate the stability of a more complex circuit. This artic...[Details]
We know that microcontroller development tools generally include real-time online emulators and programmers. Among them, online emulators are very good tools, but they are also more expensive...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
1. Introduction
Testing the temperature of steel billets before rolling is an important measure to ensure the quality of steel. Traditional manual testing is difficult to ensure product qu...[Details]
On the afternoon of July 10, Beijing time, Taiwan's largest chip designer MediaTek expects its smartphone chip shipments to grow by double digits in the third quarter of this year, and the company is ...[Details]
PV inverter manufacturer SMA has launched its first DC arc fault circuit interrupter (AFCI) PV inverter and has received UL certification.
The new SunnyBoy AFCI inverter models include 3000-US...[Details]
With concerns about the growing energy crisis, motor efficiency has become an important and timely topic. This is because motors use 63% to 70% of the electricity produced in the United States and ...[Details]
Spatial Division Multiplexing (SDM) MIMO processing can significantly improve spectrum efficiency and thus greatly increase the capacity of wireless communication systems. Spatial Division Multip...[Details]