TECHNICAL DATASHEET
PMF Panel Mount Power Supply
24V 200W 1 Phase / PMF-24V200WC
□□
PMF
Highlights & Features
–
–
–
–
–
–
–
–
–
Universal AC input voltage
Built-in Active PFC and fan speed control
Full Aluminium casing for light weight and corrosion resistant
handling
Conforms to harmonic current IEC/EN 61000-3-2, Class A
and Class D
Remote ON/OFF is available as an option
Cold start -20°C at 100% load (200W)
Low leakage current < 0.5mA @ 240Vac
High MTBF > 700,000 hrs. as per Telcordia SR-332
Short Circuit / Overvoltage / Overcurrent / Over Temperature
Protections
Safety Standards
CB Certified for worldwide use
Model Number:
PMF-24V200WC☐☐
Unit Weight:
0.66 kg
Dimensions (L x W x D):
190 x 93 x 50 mm
General Description
The PMF Panel Mount Power Supply series currently offers nominal output voltages of 24V. These power supply units come with
universal AC input from 85Vac to 264Vac and wide operating temperature of -10°C to +70°C. The built-in active PFC provides high
power factor and conforms to harmonic current IEC/EN 61000-3-2, Class A and Class D. This versatile series has two different
connector options (Front Face and Terminal Block) to satisfy different application needs. Remote ON/OFF function is also available for
the PMF series. All PMF power supplies conform to major international safety standards including IEC/EN/UL 60950-1 standards and
are fully compliant with RoHS Directive 2011/65/EU for environmental protection.
Model Information
PMF Panel Mount Power Supply
Model Number
PMF-24V200WC☐☐
Input Voltage Range
85-264Vac
Output Voltage
24Vdc
Output Current
8.40A
Model Numbering
CC Code
PM
Panel Mount
F–
24V
200W
Output Power
C
Package Type
C – Enclosed
□
□
Product Series Output Voltage
F – PFC Series
Connector Type
Variable
G – Front Face
B – No Remote ON/OFF
A – Terminal Block* R – With Remote ON/OFF*
*Options
1
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (November 2013, Rev. 00)
TECHNICAL DATASHEET
PMF Panel Mount Power Supply
24V 200W 1 Phase / PMF-24V200WC
□□
Specifications
Input Ratings / Characteristics
Nominal Input Voltage
Input Voltage Range
Nominal Input Frequency
Input Frequency Range
Input Current
Efficiency at 100% Load
Max Inrush Current
Power Factor
Leakage Current
100-240Vac
85-264Vac
50-60Hz
47-63Hz
< 3.50A @ 115Vac, < 1.70A @ 230Vac
87.0% typ. @ 230Vac
< 30A @ 115Vac, < 50A @ 230Vac
> 0.99 typ. @ 115Vac, > 0.95 typ. @ 230Vac
< 0.5mA @ 240Vac
Output Ratings / Characteristics
Nominal Output Voltage
Output Voltage Tolerance
Output Voltage Adjustment Range
Output Current
Output Power
Line Regulation
Load Regulation
PARD (20MHz)
Rise Time
Start-up Time
Hold-up Time
Dynamic Response (Overshoot & Undershoot O/P Voltage)
Start-up with Capacitive Loads
Remote ON/OFF Function (Option)
CN102
24Vdc
± 1% (initial set point tolerance from factory)
21.6-26.4Vdc
8.40A
201.6W
± 0.5% typ. (@ 115Vac & 230Vac)
± 0.5% typ. (@ 115Vac & 230Vac)
< 150mVpp @ 25°C
< 300mVpp @ -10°C
50ms typ. @ 115Vac & 230Vac (100% load)
1200ms typ. @ 115Vac & 230Vac (100% load
)
20ms typ. @ 115Vac & 230Vac
± 5% (2.4V pk-pk) @ 115Vac & 230Vac (0-100% load)
8,000µF Max
Output ON: 5-12.5V
Output OFF: 0-0.5V
(For more information, please refer to the details in the
Functional Manual section on Page 10)
Mechanical
Case Chassis
Case Cover
Dimensions (L x W x D)
Unit Weight
Indicator
Cooling System
Terminal
Wire
PMF-24V200WCG☐
PMF-24V200WCA☐
Aluminium
Aluminium
190 x 93 x 50 mm
0.66 kg
Green LED (DC OK)
Forced Cooling
M3.5 x 7 Pins (Rated 300V/20A)
M3.5 x 7 Pins (Rated 300V/15A)
AWG 20-12
2
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (November 2013, Rev. 00)
TECHNICAL DATASHEET
PMF Panel Mount Power Supply
24V 200W 1 Phase / PMF-24V200WC
□□
Environment
Surrounding Air Temperature
Power De-rating
Operating Humidity
Operating Altitude
Shock Test (Non-Operating)
Vibration (Non-Operating)
Pollution Degree
Operating
Storage
-10°C to +70°C (Cold start at -20°C)
-25°C to +85°C
> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 1.33% / 1V
10-95% RH (Non-Condensing)
0 to 5,000 Meters
IEC 60068-2-27, Half Sine: 50G for a duration of 11ms,
3 shocks for each 3 directions
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms);
20 min per axis for all X, Y, Z direction
2
Protections
Overvoltage
Overload / Overcurrent
Over Temperature
Short Circuit
Protection Against Shock
*PE: Primary Earth
27.6-32.4V, Latch Mode
(AC power is recycled)
105-150%, Hicc-up Mode, Non-Latching
(Auto-Recovery)
Hicc-up Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Hicc-up Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Class I with PE* connection
Reliability Data
MTBF
Expected Cap Life Time
> 700,000 hrs. as per Telcordia SR-332
I/P: 100Vac, O/P: 100% load, Ta: 35°C
10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety Standards / Directives
Electrical Safety
TUV Bauart to EN 60950-1, UL/cUL recognized to UL
60950-1 and CSA C22.2 No. 60950-1, CB scheme to
IEC 60950-1, CCC to GB4943
In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
RoHS Directive 2011/65/EU Compliant
Input to Output
Input to Ground
Output to Ground
3.0KVac
2.0KVac
0.5KVac
CE
Material and Parts
Galvanic Isolation
3
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (November 2013, Rev. 00)
TECHNICAL DATASHEET
PMF Panel Mount Power Supply
24V 200W 1 Phase / PMF-24V200WC
□□
EMC
EMC / Emissions
Immunity to
Electrostatic Discharge
IEC 61000-4-2
Level 4 Criteria A
1)
Air Discharge: 15kV
Contact Discharge: 8kV
Level 3 Criteria A
1)
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
Level 3 Criteria A
1)
2kV
Level 3 Criteria A
1)
Common Mode
2)
: 2kV
3)
Differential Mode : 1kV
Level 3 Criteria A
1)
150kHz-80MHz, 10Vrms
Criteria A
1)
10A/Meter
100% dip; 1 cycle (20ms); Self Recoverable
Level 3 Criteria A
1)
Common Mode
2)
: 2kV
Differential Mode
3)
: 1kV
IEC/EN 61000-3-2, Class A and Class D
IEC/EN 61000-3-3
CISPR 22, EN 55022, FCC Title 47: Class B
Radiated Field
Electrical Fast Transient / Burst
Surge
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
Conducted
Power Frequency Magnetic Fields
Voltage Dips
Low Energy Pulse Test (Ring Wave)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC61000-4-12
Harmonic Current Emission
Voltage Fluctuation and Flicker
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
4
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (November 2013, Rev. 00)
TECHNICAL DATASHEET
PMF Panel Mount Power Supply
24V 200W 1 Phase / PMF-24V200WC
□□
Block Diagram
Device Description
PMF-24V200WCG☐:
Front Face
PMF-24V200WCA☐:
Terminal Block
1)
2)
3)
4)
Input & Output terminal block connector
DC voltage adjustment potentiometer
DC OK control LED (Green)
Remote ON/OFF function connector (Option)
5
All parameters are specified at 25°C ambient unless otherwise indicated.