GLD140CG

Description
Switching Power Supplies 140W MULTIPLE OUTPUT 5, 12, 15, -15V OUT
CategoryPower/power management   
File Size136KB,2 Pages
ManufacturerSL Power
Download Datasheet Parametric Compare View All

GLD140CG Online Shopping

Suppliers Part Number Price MOQ In stock  
GLD140CG - - View Buy Now

GLD140CG Overview

Switching Power Supplies 140W MULTIPLE OUTPUT 5, 12, 15, -15V OUT

GLD140CG Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerSL Power
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 15 VDC
Output Voltage-Channel 212 VDC
Number of Outputs4 Output
Output Power140 W
Open Frame/EnclosedOpen Frame
Input Voltage90 VAC to 264 VAC
Output Current-Channel 116 A
Output Current-Channel 26 A
Commercial/MedicalMedical
Mounting StyleChassis
Length8.5 in
Width4.5 in
Height1.95 in
ApprovalsEN60601-1
Cooling MethodConvection, Air-Cooled
Input Voltage, Max264 VAC
Input Voltage, Min90 VAC
Load RegulationRegulated
Mechanical StyleOpen / Enclosed Frame
Operating Temperature Range0 C to + 50 C
Output Current-Channel 34 A
Output Current-Channel 4750 mA
Output Voltage V1, Nominal5 VDC
Output Voltage V2, Nominal12 VDC
Output Voltage V3, Nominal15 VDC
Output Voltage V4, Nominal- 15 VDC
Output Voltage-Channel 315 VDC
Factory Pack Quantity100
GLD140 Gold Performance Medical Switchers
140 Watt Multiple Output
FEATURES:
Compact size (4.5" x 8.5" x 1.95")
Power factor corrected to IEC 1000-3-2 Class A
Documented FMEA, WCA and EMC test results
EMI compliance to CISPR11, FCC Class B, IEC601-1-2
Approved to UL2601, IEC601-1 and
CSA 22.2 No. 601.1-M90 and EN60601: 1990
marked to LVD
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase.
Output Power
Continuous output power 140 W with unrestricted convection
cooling, 180 W with 150 LFM of air.
Input Current
Active Power Factor Correction circuitry assures compliance
with IEC1000-3-2, Class A. Maximum input current at minimum
input voltage and full load is 3.0 A.
Efficiency
73 – 85 % at full rated load, nominal input voltage, depending on
model and load distribution.
Hold-up Time
26 ms total. 16 ms minimum from loss of ac input at full load until
activation of the power fail signal. Output voltages remain within
specified regulation limits for an additional 9 ms minimum after
power fail activates.
Overload Protection
Fully protected against short circuit and output overload. Short
circuit protection is cycling type power limit.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode.
Measured with noise probe directly across output terminals of
the power supply.
Transient Response
500 µs typical response time for return to within 0.5% of final
value for a 45% load step from any load greater than 10% of full
rated load,
∆i/∆t<
0.2 A µs. Maximum voltage deviation is 3.5%.
Remote Sense
Provided as a standard feature on V1 and V2.
Overvoltage Protection
Built in on V1, 2 and 3 outputs.
Voltage Adjustment
Factory set to specified voltage with user adjustable potentiom-
eter on V1, 2 and 3. User can adjust V1, 2 and 3 at least ±5% of
nominal output voltage.
Output Regulation
Regulation for all outputs is the maximum deviation from initial
set point under all line and load conditions. Initial set tolerance is
measured with all outputs at 50 % of full rated load.
No Load Turn-On/Standby
A minimum load of 3 A on V1 is required for proper regulation. If
not met, no degradation of reliability will occur.
Temperature Coefficient
0.03% / °C typical on all outputs.
Input Protection
Internal ac fuses provided on both lines on all units.
Inrush Current
Inrush is limited by internal thermistors. The inrush at 240 Vac,
averaged over the first ac half-cycle under cold start conditions
will not exceed 37 A.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit from
prolonged over temperature.
Power Fail
TTL / CMOS compatible output goes low (<0.5 V) 10 ms before
output voltage drops more than 4% below nominal voltage upon
loss of ac power.
Power Good
TTL / CMOS compatible output rises high 100 to 300 ms after V1
reaches regulation and should assure that sufficient energy is
stored in the input section to provide normal power fail /
shutdown.
Inhibit
Inhibit signal when pulled to the V1 output common will inhibit all
output voltages.
Fan Output
An additional thermally controlled 12 Vdc, 250 mA output suitable
for powering a dc fan is included in all models (Factory installed
cover with fan makes this output unavailable).
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following
requirements:
EMC SPECIFICATION
COMPLIANCE LEVEL
Conducted Emissions
EN55011, Class B; FCC Class B
Static Discharge
EN61000-4-2, 6 kV contact 8 kV air
RF Field Susceptibility
EN61000-4-3, 3V/meter
Fast Transients / Bursts
EN61000-4-4, 2 kV, 5 kHz
Surge Susceptibility
EN61000-4-5, 1 kV diff., 2 kV com.
Conducted RF Susceptibility EN61000-4-6, 3V
Voltage Sags & Surges
EN61000-4-11
Line Frequency Harmonics
EN61000-3-2 Class A
EMC Compliance for Gold Series
Magnetic Emissions - Emissions will not exceed the limits of the
Army curve in MIL-STD-461D, RE101 when measured at 7 cm
from 30 Hz - 100 kHz over all nominal inputs and at full rated load.
Leakage Current
70 µA under normal conditions 120 Vac @ 60 Hz
Single fault conditions 280 µA, 264 Vac @ 50 Hz.
SAFETY AGENCY APPROVALS:
All models are Certified to be in compliance with the
applicable requirements of UL2601-1, CSA-C22.2 No. 601.1,
IEC 601-1/60601-1.
DESIGN VERIFICATION DOCUMENTS
The “Gold” series has undergone rigorous review and design
analysis. The following product documentation is available upon
request: 1. Failure Mode and Effects analysis (FMEA), 2. DVT
Data, 3. EMC / Susceptibility test results.
58
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com

GLD140CG Related Products

GLD140CG GLD140EG
Description Switching Power Supplies 140W MULTIPLE OUTPUT 5, 12, 15, -15V OUT
Product Category Switching Power Supplies Switching Power Supplies
Manufacturer SL Power SL Power
RoHS Details Details
Product Switching Supplies Switching Supplies
Output Voltage-Channel 1 5 VDC 5 VDC
Output Voltage-Channel 2 12 VDC 24 VDC
Number of Outputs 4 Output 4 Output
Output Power 140 W 140 W
Open Frame/Enclosed Open Frame Open Frame
Input Voltage 90 VAC to 264 VAC 90 VAC to 264 VAC
Output Current-Channel 1 16 A 16 A
Output Current-Channel 2 6 A 4 A
Commercial/Medical Medical Medical
Mounting Style Chassis Chassis
Length 8.5 in 8.5 in
Width 4.5 in 4.5 in
Height 1.95 in 1.95 in
Approvals EN60601-1 EN60601-1
Cooling Method Convection, Air-Cooled Convection, Air-Cooled
Input Voltage, Max 264 VAC 264 VAC
Input Voltage, Min 90 VAC 90 VAC
Load Regulation Regulated Regulated
Mechanical Style Open / Enclosed Frame Open / Enclosed Frame
Operating Temperature Range 0 C to + 50 C 0 C to + 50 C
Output Current-Channel 3 4 A 4 A
Output Current-Channel 4 750 mA 750 mA
Output Voltage V1, Nominal 5 VDC 5 VDC
Output Voltage V2, Nominal 12 VDC 24 VDC
Output Voltage V3, Nominal 15 VDC 15 VDC
Output Voltage V4, Nominal - 15 VDC - 15 VDC
Output Voltage-Channel 3 15 VDC 15 VDC
Factory Pack Quantity 100 10

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2459  817  511  797  2136  50  17  11  44  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号