ZUP
SERIES
ks
医 療
ProgrammableCVCC200W 〜 800W 19Model
その他
計 測
F A
半導½
その他
ph
800W
200W, 400W
その他
pf-a
その他
コンピュータ
通 信
F A
半導½
warranty
3
Y
E
A
R
S
■Features
●
●
●
●
●
●
●
Constant Voltage/Constant Current
Built-in RS232 & RS485 Interface
hk-a
An embedded Microprocessor controller
Digital Encoder Knob
Software Calibration
Last Setting Memory
hws
Parallel Operation (Master/Slave) Active Current
医 療
■Modelnamingmethod
ZUP36-12/
Series name
Output
Output
Voltage
Current
( 0 〜 36V ) ( 0 〜 12A )
Serial Link Cable
W. Cable included
BLANK: None
Front Panel
L. Output Jacks
BLANK: Standard
コンピュータ
通 信
Sharing
● External Voltage or Resistance Programming
■Applications
計 測
F A
半導½
AC Cable
E. Europe
U. USA
O. Unterminated
その他
I: SI 32 std.
BLANK: None
● Voltage up to 120V, Current up to 132A
フォーマット
● Active Power Factor Correction: 99%
●
●
●
●
85〜265Vac Universal Input Voltage
19" Rack Mounted ATE and OEM
Worldwide Safety Agency Approvals
CE Mark for LVD and
alpha
EMC Regulation
コンピュータ
通 信
医 療
■ConformitytoRoHSDirective
その他
This means that, in conformity with EU Directive 2002/95/
計 測
F A
半導½
EC, lead, cadmium, mercury, hexavalent chromium, and
have not been used, except for exempted applications.
その他
specific bromine-based flame retardants, PBB and PBDE,
■ProductLineup
200W
Output Voltage
0-6V
0-10V
0-20V
0-36V
0-60V
0-80V
0-120V
Output Current
0-33A
0-20A
0-10A
0-6A
0-3.5A
0-2.5A
0-1.8A
dlp
コンピュータ
通 信
医 療
計 測
F A
半導½
400W
Output Current
0-66A
0-40A
0-20A
通 信
医 療
0-12A
0-7A
0-5A
0-3.6A
Model
ZUP6-66
ZUP10-40
ZUP20-20
計 測
F A
ZUP36-12
ZUP60-7
ZUP80-5
ZUP120-3.6
Output Current
0-132A
0-80A
その他
0-40A
半導½
0-24A
0-14A
ー
ー
800W
Model
ZUP6-132
ZUP10-80
ZUP20-40
ZUP36-24
ZUP60-14
ー
ー
fps
Model
ZUP6-33
ZUP10-20
ZUP20-10
コンピュータ
ZUP36-6
ZUP60-3.5
ZUP80-2.5
ZUP120-1.8
ZUP
・All specifications are subject to change without notice.
A-341
ZUP
SERIES
ZUP Specifications
ITEMS/UNITS
MODEL
ZUP6-33
ZUP6-66
ZUP6-132
ZUP10-20
ZUP10-40
ZUP10-80
ZUP20-10
OUTPUT VOLTAGE
(*1)
OUTPUT CURRENT
(*2)
RATED OUTPUT POWER
LOAD REGULATION
LINE REGULATION
RMS RIPPLE (5Hz-1MHz Bandwidth)
RIPPLE (pk to pk) (20MHz Bandwidth)
(*3)
CONSTANT RECOVERY TIME
VOLTAGE TEMPERATURE COEFFICIENT
TEMPERATURE DRIFT
UP PROGRAMMING RESPONSE TIME (*4)
DOWN PROGRAMMING FULL LOAD
RESPONSE TIME
NO LOAD
LOAD REGULATION
(*5)
LINE REGULATION
(*6)
CONSTANT
RMS RIPPLE (5Hz-1MHz Bandwidth)
CURRENT
TEMPERATURE COEFICIENT
TEMPERATURE DRIFT
(*8)
RESOLUTION
ACCURACY
PROGRAM VOLTAGE
MING (*9)
RESOLUTION
CURRENT
ACCURACY
OVERVOLTAGE PROTECTION
(*10)
HOLD-UP TIME
VOLTAGE
DISPLAY CURRENT
STATUS
OUTPUT PROTECTIONS
INPUT VOLTAGE
(*11)
INPUT CURRENT
(*12)
INRUSH CURRENT ( 100/200V )
INPUT
EFFICIENCY ( *12 )
INPUT CURRENT HARMONICS
POWER FACTOR (TYP)
OPERATING TEMPERATURE
OPERATING HUMIDITY
ENVIRONMENT
STORAGE TEMPERATURE
STORAGE HUMIDITY
VIBRATION
SHOCK
MECHANICAL
WEIGHT
SIZE (W x H x D)
OUTPUT ON/OFF
OUTPUT GOOD
EXTERNAL
OUTPUT VOLTAGE PROGRAMMING
CONTROL
OUTPUT CURRENT PROGRAMMING
FUNCTIONS
REMOTE SENSING
COMMUNICATION INTERFACE
SAFETY STANDARDS
APPROVALS
EMC STANDARDS
CONDUCTED EMI
RADIATED EMI
SERIES OPERATION
PARALLEL OPERATION
COOLING
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
V
A
W
mV
mV
mS
mS
mS
mS
mA
V
A
A
%
Kg
mm
0-6
0-10
0-66
0-132
0-20
0-40
0-80
0-10
396
792
200
400
800
200
0.005%+2mV From No load to Full load, constant input voltage.
0.005%+1mV From 85-132VAC or 170-265VAC, constant load.
5
5
8
5
5
8
5
50
50
100
50
50
90
50
1
0.5
30ppm/…C from rated voltage following 30-minute warm-up.
0.01%+2mV Change in output over 8-hour interval under constant line, load and ambient temp following30-minute warm-up.
50
50
60
50
50
60
50
50
50
50
50
50
50
50
250
350
0.01%+5mA 0.01%+5mA 0.07%+10mA 0.01%+5mA 0.01%+5mA 0.07%+10mA 0.01%+5mA
0.01%+2mA 0.01%+2mA 0.01%+5mA 0.01%+2mA 0.01%+2mA 0.01%+5mA 0.01%+2mA
50
100
200
25
50
100
15
100ppm/
…C
from rated current following 30-minute warm-up.
0.02%+5mA 0.02%+5mA 0.05%+10mA 0.02%+5mA 0.02%+5mA 0.05%+10mA 0.02%+5mA
Better than 0.028% of rated output voltage
0.02%+5mV
0.02%+8mV
Better than 0.03% of rated output current
0.4%+40mA
0-7.5
0-13
20mS At 100V/200VAC, rated output voltage and output current.
3 digits ( 6v; 20v; 36v; 60v; 80v); 3.5 digits ( 10v; 120v ) accuracy: 0.2% +/- 2 digits.
3.5 digits (132A); All others 3 digits, accuracy: 0.5% +/- 3 digits.
CV/CC, Alarm, Fold, Local/Remote, On/Off.
Over Voltage, Over Temperature, Foldback.
85-265Vac Continuous, 47-63Hz
3.0/1.5
5.6/2.7
11.2/5.4
2.9/1.4
5.6/2.7
11.2/5.4
2.9/1.4
15/30 (*7)
15
30
15/30 (*7)
15
30
15/30 (*7)
69/72
74/77
74/77
73/77
79/82
77/81
74/78
Complies with EN61000-3-2, Class A
0.99 at 100/200Vac, 100% load.
0 to 50
…C
; 100% Load.
30-90% RH ( No dewdrop ).
-20 to 70
…C
10 - 95% RH (No dewdrop).
10-55Hz, Amplitude (sweep 1 min ) 2G, X, Y, Z, When mounted with mounting screws.
Less than 20G
2.9
3.2
5.8
2.9
3.2
5.8
2.9
200W and 400W units: 70 x 124 x 350. 800W units: 140 x 124 x 350 (Refer to outline drawing)
By TTL Signal or Dry Contact (Refer to instruction manual).
Open collector (Refer to instruction manual).
By Voltage ( 0-4V ) or by Resistance ( 0-4K ) (Refer to instruction manual).
By Voltage ( 0-4V ) or by Resistance ( 0-4K ) (Refer to instruction manual).
Maximum 0.5V drop on each load wire for model up to 60V and 2V for the 80V, 120V models
RS232 and RS485 Built-in, IEEE488 Optional.
UL3111-1, EN61010-1
EN61326-1, IEC 61326-1, FCC part 15 (class A).
EN55022-B, FCC-B, VCCI-2
EN55022-A, FCC-A, VCCI-1
Up to 2 units (Refer to instruction manual).
Master - Slave method; up to 5 units (Refer to instruction manual).
Forced air by blower fan (Blower fan is mounted within unit).
Input - Chassis...2.0kVAC 1 min, Input - Output...3.0kVac 1 min, Output - GND...500VAC 1 min.
More than 100MOhm at 25
…C
and 70% R.H.
0-33
198
(*1) Minimum voltage is guaranteed to maximum 0.2% of the rated out-
put voltage.
(*2) Minimum current is guaranteed to maximum 0.4% of the rated out-
put current.
(*8) Change in output over 8 hour interval constant line, load and ambi-
ent temperature following 30-minutes warm-up.
(*9) Given for control of the output via the serial communication or via
front panel controls.
(*10) Inverter shut down method, manual reset (OVP will shut down out-
put)
(*11) For cases where conformance to various safety specs. (UL, IEC,
etc.) are required, to be described as 100-240VAC (50/60Hz) on
name plate.
(*12) At 100V/200V and Maximum Output Power.
- When forced air cooling, refer to derating curve.
ZUP
(*3) Time for recovery to within +/-50mV against current change of 50%
to 100%.
(*4) From zero volts to full scale , resistive load and current setting at
maximum.
(*5) From no load to full load , constant input voltage.
(Measure with JEITA RC-9131 probe.)
(*6) From 85~132Vac or 170~265Vac constant load.
(*7) At cold start Ta=25
…C.
A-342
・All specifications are subject to change without notice.
ZUP
SERIES
Outline Drawing
[ZUP 200W/400W Units]
11.0
11.0
11.0
Note 1
External
Control
Note 1 Note 1
Connector
External External
Control Control
19.0
Connector
Connector
Note 1
External
Control
Connector
19.0
19.0
± 0.5
unit: mm
70x124x350
IEC320
RS232/RS485
AC Inlet
communication
20.0
20.0
connectorsIEC320 IEC320
RS232/RS485
RS232/RS485
20.0
IEC320
AC Inlet AC Inlet
RS232/RS485
communication
communication
AC Inlet
communication
connectors
connectors
connectors
59.5
20.0
20.0
48.4
±0.5
B
48.4
±0.5
B
B
B
B
48.4 48.4
±0.5 ±0.5
WEIGHT: Kg
200W units:2.9
400W units:3.2
B
B
B
B
Mounting Holes
Mounting Holes
Tap M4 4 marked A
Tap M4 x
x
4 marked A
B
B
B
B
B
13.0
13.0
B
± 0.5
±
± 0.5
0.5
59.5
59.5
20.0
20.0
20.0
59.5
B
13.0 13.0
131.0 ± 1.0
Rear Panel
Output Voltage
Connector
For 80V, 120V
Models.
Note:
1: Housing AMP: 87631-9
with pins AMP: 87523-6.
2: Header PHOENIX: PSC 1,5/3-M-PE
Plug PHOENIX: PSC 1,5/3-3-F
Plastic cable housing
Included with the power supply.
Mounting Mounting Holes
Holes
Tap M4 x 4 marked 4 marked A
Tap M4 x A
Rubber Bumpers Bumpers
Rubber
4 places marked B marked B
4 places
(removable)
(removable)
Rubber Bumpers
Rubber Bumpers
4 places
B
4 places marked
marked B
(removable)
(removable)
[ZUP 800W Unit]
REMOVABLE HANDLE
REMOVABLE HANDLE
REMOVABLE HANDLE HANDLE
REMOVABLE
124.0 ± 0.5
139.5 ± 1.0
131.0 ± 1.0
ADDR
OVP/UVP
V/A
FOLD
REM
OUT
1
External
Control
Note 1 Note 1
Connector
External External
Control Control
47.0
Connector
Connector
Note 1
External
Control
Connector
Note
47.0
131.0131.0 ± 1.0
± 1.0
11.0
19.0
131.0 ± 1.0
46.3
47.0
47.0
46.3
46.3
46.3
124.0124.0 ± 0.5
± 0.5
ADDR
OVP/UVP
V/A
FOLD
REM
OUT
POWER
ADDR
OVP/UVP
V/A
FOLD
REM
ADDR
OVP/UVP
OUT
V/A
FOLD
REM
OUT
20.0
99.6± 1
unit:
140x124x350 mm
POWER
WEIGHT:
5.8
POWER
kg
99.6±
RS232/RS485
communication
connectors
139.5139.5 ± 1.0
± 1.0
131.0131.0 ± 1.0
± 1.0
124.0 ± 0.5
139.5 ± 1.0
131.0 ± 1.0
IEC320
AC Inlet
20.0
1
POWER
20.0 99.6± 1 99.6± 1
Note:
1: Housing AMP: 87631-9
with pins AMP: 87523-6.
Included with the power supply.
RS232/RS485
communication
connectors
RS232/RS485
RS232/RS485 IEC320
communication
communication AC Inlet
connectors
connectors
Mounting Holes: Tap M4 x 4 marked A
IEC320
AC Inlet
IEC320
AC Inlet
Rubber Bumpers:
4 places marked B (removable)
ZUP
Mounting Holes: Tap M4 x 4 marked A
Rubber Bumpers:
4 places marked B (removable)
Rubber Bumpers:Bumpers:
Rubber
4 places marked Bmarked B (removable)
4 places (removable)
Mounting Mounting Holes: 4 marked 4 marked A
Holes: Tap M4 x Tap M4 x A
A-344
l
All specifications are subject to change without notice.