CCG15-48-xxS
C269-01-01A
TDK-Lambda
SPECIFICATIONS
MODEL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
ITEMS
Nominal Output Voltage
Maximum Output Current
Nominal Output Power
Efficiency (Typ.)
Input Voltage Range
Input Current
Output Voltage Accuracy
Output Voltage Range
Maximum Ripple & Noise
Maximum Line Regulation
Maximum Load Regulation
Over Current Protection
Over Voltage Protection
Remote ON/OFF control
Parallel Operation
Series Operation
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Cooling
Temperature Coefficient
Withstand Voltage
V
A
W
%
VDC
A
%
%
mV
mV
mV
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
CCG15-48-03S
3.3
4
13.2
85
0.32
CCG15-48-05S
5
3
15
87
18 - 76
0.36
±2
±10
70
13.2
13.2
70
95
20
48
20
48
105% min. (Hiccup, Automatic recovery method)
-
Possible (SHORT : ON OPEN : OFF)
-
Possible
-40°C - +110°C(Case) , -40°C - +85°C(Ambient)
5 - 95%RH (No Dewdrop)
-55°C - +125°C
5 - 95%RH (No Dewdrop)
Convection cooled / Forced air cooled
0.02%/°C
Output-Case : 1.0kVDC for 1min. (10mA)
CCG15-48-12S
12
1.3
15.6
88
0.37
CCG15-48-15S
15
1
15
88
0.36
(*1)
(*1)
(*1)
(*6)
(*2)
(*3)
95
60
60
(*5)
(*5)
(*4)
(*7)
Input-Case : 1.0kVDC for 1min. (10mA) , Input-Output : 1.5kVDC for 1min. (10mA)
24 Isolation Resistance
25 Vibration
26 Shock
27 Safety
28 Weight (Typ.)
29 Size (W x H x D)
Output to Case 500VDC more than 100MW (25°C,70%RH)
At No Operating, 10-55Hz (Sweep for 3min.)
Amplitude 1.52 mm Constant (Maximum 90.8m/s
2
) X,Y,Z 1 hour each
2
490.3m/s
Approved by UL60950-1, CSA60950-1, EN60950-1
20
25.4 x 9.9 x 25.4 (Refer to Outline Drawing)
*Read Instruction Manual carefully, before using the power supply unit.
=NOTES=
*1. At 48VDC and maximum output current.
(Ambient Temperature = +25°C.)
*2. 18 - 76VDC, Constant load.
*3. No Load - Full Load, Constant input voltage.
*4. Rating - Refer to Instruction Manual.
*5. Refer to Instruction Manual.
*6. External components are needed for operation.
(Refer to Instruction Manual.)
*7. This specification applies to power supply module as stand-alone.
CCG15-48-xxS
C269-01-02
BASIC CONNECTION
TDK-Lambda
*Read instruction manual carefully, before using the power supply unit.
==NOTES==
*1. Use an external fuse (fast blow type or normal blow type) for each unit.
*2. Put input capacitor.
C1 : Electrolytic capacitor More than 100V, 47uF
1) Use low impedance electrolytic capacitor with excellent temperature characteristics.
2) If the impedance of input line is high, C1 capacitance must be more than above.