(2/5)
C A P A C I T O R S
REMINDERS FOR USING THESE PRODUCTS
(1) During transportation and storage
Do not transport or store where the prodcuts will be exposed to high temperature or high humidity.
Do not expose to poisonous gases such as H
2
SO
4
, HCl, or HNO
3
.
Avoid excessive impact such as that caused by falling.
(2) During operation
Avoid contact with electrolytes such as perspiration. Do not touch with bare hands.
Avoid excessive impact such as that caused by falling.
Do not apply solder to stud terminals.
Do not re-machine the terminals.
(3) Usage
Make sure that the prodcuts are not exposed to radiant heat from chambers or transformers.
(4) Others
The products listed on this catalog are not designed or warranted to meet the requirements of the applications listed below, whose perfor-
mance and/or quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious
damage to society, person or property.
If you intend to use the products in the applications listed below or if you have special requirements exceeding the range or conditions set
forth in the each catalog, please contact us.
(1) Aerospace/aviation equipment
(2) Transportation equipment (cars, electric trains, ships, etc.)
(3) Medical equipment
(4) Power-generation control equipment
(5) Atomic energy-related equipment
(6) Seabed equipment
(7) Transportation control equipment
(8) Public information-processing equipment
(9) Military equipment
(10) Electric heating apparatus, burning equipment
(11) Disaster prevention/crime prevention equipment
(12) Safety equipment
(13) Other applications that are not considered general-purpose
applications
When designing your equipment even for general-purpose applications, you are kindly requested to take into consideration securing pro-
tection circuit/device or providing backup circuits in your equipment.
20170227 / uhv_uhv_en.fm
(3/5)
C A P A C I T O R S
Ultra high voltage ceramic capacitors
With metal terminals
For high voltage power supplies/lasers
Product compatible with RoHS directive
Overview of UHV series
FEATURES
A lineup with a rated voltage of Edc:20 to 50kV
low ESR
Low-loss and low distortion factor
Molded type metal screw terminals for easy mounting
Uses high-reliability mold resin
APPLICATION
High-voltage power circuits (for medical devices, lithography, industrial analyzers)
OPERATING TEMPERATURE RANGE, PRODUCT WEIGHT
Temperature range
Part No.
Sub part No.
Operating
temperature
(°C)
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
Storage
temperature
(°C)
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
–30 to +85
Individual weight
UHV-221A
UHV-222A
UHV-223A
UHV-224A
UHV-1A
UHV-2A
UHV-3A
UHV-231A
UHV-232A
UHV-233A
UHV-4A
UHV-5A
UHV-6A
UHV-241A
UHV-242A
UHV-243A
UHV-7A
UHV-8A
UHV-9A
UHV-251A
UHV-252A
UHV-253A
UHV-10A
UHV-11A
UHV-12A
60711ZT201K4DDA
60716ZT401K4DDA
60721ZT701K4DDA
60725ZT102K4DDA
60729ZT142K4DDA
60739ZT252K4DDA
60750ZT402K4DDA
60713ZT201K4FDA
60719ZT401K4FDA
60725ZT701K4FDA
60729ZT941K4FDA
60739ZT172K4FDA
60750ZT272K4FDA
60711ZT101K4GDA
60716ZT201K4GDA
60722ZT401K4GDA
60729ZT701K4GDA
60739ZT132K4GDA
60750ZT202K4GDA
60712ZT101K4HDA
60718ZT201K4HDA
60726ZT401K4HDA
60729ZT561K4HDA
60739ZT102K4HDA
60750ZT172K4HDA
(g)
14
25
40
53
75
115
170
28
46
63
83
138
210
22
38
72
112
173
261
25
61
88
126
199
297
RoHS Directive Compliant Product: See the following for more details.https://product.tdk.com/info/en/environment/rohs/index.html
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20170227 / uhv_uhv_en.fm
(5/5)
C A P A C I T O R S
UHV series
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS SPECIFICATION TABLES
Class 2 (Temperature stable)
Temperaturecharacteristics:
Z5T(+10
to
+85°C, +22/–33%)
Part No.
Sub part No.
Rated voltage
Capacitance
Withstanding
voltage
[1min, in oil]
(kV)
30
30
30
30
30
30
30
45
45
45
45
45
45
60
60
60
60
60
60
75
75
75
75
75
75
Dissipation
factor (tan)
(%) max.
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
Insulation
resistance
(M) min.
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
100000
AC corona
starting voltage
[3PC
]
(kVAC) min.
10
10
10
10
10
10
10
15
15
15
15
15
15
20
20
20
20
20
20
25
25
25
25
25
25
UHV-221A
UHV-222A
UHV-223A
UHV-224A
UHV-1A
UHV-2A
UHV-3A
UHV-231A
UHV-232A
UHV-233A
UHV-4A
UHV-5A
UHV-6A
UHV-241A
UHV-242A
UHV-243A
UHV-7A
UHV-8A
UHV-9A
UHV-251A
UHV-252A
UHV-253A
UHV-10A
UHV-11A
UHV-12A
60711ZT201K4DDA
60716ZT401K4DDA
60721ZT701K4DDA
60725ZT102K4DDA
60729ZT142K4DDA
60739ZT252K4DDA
60750ZT402K4DDA
60713ZT201K4FDA
60719ZT401K4FDA
60725ZT701K4FDA
60729ZT941K4FDA
60739ZT172K4FDA
60750ZT272K4FDA
60711ZT101K4GDA
60716ZT201K4GDA
60722ZT401K4GDA
60729ZT701K4GDA
60739ZT132K4GDA
60750ZT202K4GDA
60712ZT101K4HDA
60718ZT201K4HDA
60726ZT401K4HDA
60729ZT561K4HDA
60739ZT102K4HDA
60750ZT172K4HDA
(kV)
20
20
20
20
20
20
20
30
30
30
30
30
30
40
40
40
40
40
40
50
50
50
50
50
50
(pF)
200±10%
400±10%
700±10%
1,000±10%
1,400±10%
2,500±10%
4,000±10%
200±10%
400±10%
700±10%
940±10%
1,700±10%
2,700±10%
100±10%
200±10%
400±10%
700±10%
1,300±10%
2,000±10%
100±10%
200±10%
400±10%
560±10%
1,000±10%
1,700±10%
PC:Pico coulomb.
CAPACITANCE VS. TEMPERATURE CHARACTERISTICS
CAPACITANCE VS. DC BIAS CHARACTERISTICS
50
10
30
Z5T
0
Capacitance change rate(%)
Capacitance change rate(%)
10
–10
–10
–20
–30
–30
–50
–50
0
50
Temperature(°C)
100
–40
100%=Rated voltage
0
50
100
Rated voltage(%)
150
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20170227 / uhv_uhv_en.fm