EEWORLDEEWORLDEEWORLD

Part Number

Search

PH300F280-12

Description
Isolated DC/DC Converters 300W 12V 25A
Categorysemiconductor    Power management   
File Size383KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Download Datasheet Parametric View All

PH300F280-12 Online Shopping

Suppliers Part Number Price MOQ In stock  
PH300F280-12 - - View Buy Now

PH300F280-12 Overview

Isolated DC/DC Converters 300W 12V 25A

PH300F280-12 Parametric

Parameter NameAttribute value
Product CategoryIsolated DC/DC Converters
ManufacturerTDK Corporation
RoHSDetails
Number of Outputs1 Output
Output Power300 W
Input Voltage200 V to 400 V
Output Voltage-Channel 112 V
Output Current-Channel 125 A
Length5.75 in
Width3.38 in
Height0.5 in
PackagingBulk
ProductIsolated
Factory Pack Quantity1
PH-F Series
Full function, 50 to 300W DC-DC converters
Features
High Density
Wide Range Input
Wide output adjustment capability
Remote On/Off
Fixed Switching Frequency
International Safety Approvals
Parallel Operation
Low component count
Signals to support N+1 redundancy
Key Market Segments & Applications
Specifications
Model
Input range
Output Voltage Adj. Range
Line Regulation
Load Regulation
Ripple and Noise
Series Operation
Over Voltage Protection
Overload Protection
Remote On/Off
Remote Sensing
Parallel operation
Inverter Good signal
Auxiliary Bias Supply
Thermal Protection
Cooling
Operating Temperature Range
Storage Temperature
Temperature Coefficient
Isolation
Isolation Resistance
Safety Agency Approval
Warranty
VDC
VDC
-
-
pk-pk
-
%
%
-
-
-
-
-
-
-
°C
°C
-
-
-
-
yrs
2V
3.3V
5V
12V
15V
24V
28V
24V nom: 18-36, 48V nom: 36-76V, 110V nom: 82-185V, 280V nom: 200-400V
1.6~2.4
2.64~3.96
2~6
4.8~14.4
6~18
9.6~28.8
11.2~33.6
0.4% or 20mV (whichever is greater) over entire input range with constant load
0.8% or 40mV (whichever is greater) from no load to full load with constant input line
100mV
150mV
240mV
280mV
Possible - Refer to installation manual
150 - 180%
125 - 145%
Approximately 105 - 140%, automatic recovery
Low = ON, Open = OFF
Yes
Using current share pin (PC). Will share within 5%, see app. notes for connection details
Signal available for status of inverter
8V 10mA auxiliary voltage to supply power to interface circuits (AUX pin)
Internal sensing, self resetting
Conduction or forced air. See application notes for cooling and heatsink selection
Baseplate temperature -20°C to +85°C. -40°C start up possible - consult factory
-40°C to +85°C
0.02%/°C
Input to output: 3000VAC, Input to Baseplate: 2500VAC(1)
Output to Baseplate -100MOhm at 500VDC and 70%RH
UL60950-1, CSA60950-1, EN60950-1 and CE Mark.
Two years
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) 24V input models input to output: 2kVAC; input to baseplate: 2kVAC
has a last time buy of June 2018
1-800-526-2324 • www.us.tdk-lambda.com/lp/
153
Disclaimer: us.tdk-lambda.com/lp/legal.htm

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development