Reinforced Infocom Connectors for Harsh Environment
RJ Field Cat6
NEW
Connecting to people + technology
www.rjfield.com
Amphenol
INFORMATION
CAT5e
CAT6
CAT6A
Standard
ISO 11801
EIA/TIA 568
ISO 11801
EIA/TIA 568
ISO 11801
EIA/TIA 568
Data rate
1 GBit/s
1 GBit/s
10 GBit/s
Frequency
100 MHz
250 MHz
500 MHz
OUR SOLUTIONS
Series
RJFRB
RJF544
RJF5446
RJFEZ
RJF / RJFTV
RJF6 / RJFTV6
RJFTV ATEX
RJFTV6 ATEX
µCom-10Gb+
RJF6A / RJFTV6A
*
High reliability
cables & cordsets
*
Coming soon
CAT5e
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CAT6
X
CAT6A
Amphenol
2
Cat5e solutions
Download
the Rugged Ethernet & USB catalogue
µCom-10Gb+
Ethernet Micro Connector
Download
the catalogue
or
visit
www.amphenol-socapex.com
RUGGED ETHERNET CAT6 SOLUTIONS SELECTION GUIDE
Connectors
Series
Indust.
Ethernet Spec.
Coupling
Mechanism
Reverse
bayonet
Shape
Material
Specification
Prime Market
Page
Inustrial &
Telecom
RJFRB
Circular
Plastic
N/A
5
RJF5446
IEC 60603-7
variant 12
Push Pull
Circular
Plastic
N/A
Industrial &
Telecom
7
RJF6
IEC 60603-7
variant 11
Bayonet
Circular
Metal
MIL-DTL-26482
Industrial
Mil/Aero
9
RJF6
CAT6 in line receptacle
IEC 60603-7
variant 11
Bayonet
Circular
Metal
MIL-DTL-26482
Industrial
Mil/Aero
12
RJF6
CAT6 transversally
sealed receptacles
RJF6
CAT6 hermetic
receptacles
RJ Field Cat 6
receptacles with self
closing cap
Bayonet
Circular
Metal
MIL-DTL-26482
Mil/Aero &
Industrial
13
Bayonet
Circular
Metal
MIL-DTL-26482
Mil/Aero &
Industria
14
IEC 60603-7
variant 11
Bayonet
Circular
Metal
MIL-DTL-26482
Industrial
Mil/Aero
15
RJF TV6
Thread
Circular
Metal
MIL-DTL-38999
Series III
Mil/Aero & Rail
Mass Transit
18
Thread
Circular
Metal
21
RJF TV 6
CAT6 transversally
sealed receptacles
RJF TV 6
CAT6 hermetic
receptacles
Cable
Series
High reliabiliy Cat6
cable & cordets
Thread
Circular
Metal
MIL-DTL-38999
Series III
Mil/Aero &
Industrial
22
Thread
Circular
Metal
MIL-DTL-38999
Series III
Mil/Aero &
Industrial
23
Prime Market
Mil/Aero
Page
27
RUGGED ATEX ZONE 2 CAT6 SOLUTION SELECTION GUIDE
Connectors
Series
Indust.
Ethernet Spec.
Coupling
Mechanism
Shape
Material
Specification
Prime Market
Page
MIL-DTL-38999
Series III
Factory
Automation,
Video, Oil & Gas
RJF TV6X
EN60079-15
Thread
Circular
Metal
28
3
Amphenol
RJF TV6
CAT6 through
bulkhead receptacles
MIL-DTL-38999
Series III
Mil/Aero &
Rail Mass
Transit
TABLE
OF CONTENTS
CAT 6 Rugged Ethernet Solutions
RJFRB - CAT6 Ethernet connection system for harsh environment - Industrial Ethernet ............................................................................... 5
RJF5446 - CAT6 Ethernet connection system for harsh environment - Industrial Ethernet ........................................................................... 7
RJF6 - CAT6 Ethernet connection system for harsh environment - Industrial Ethernet .................................................................................. 9
RJF6 - CAT6 in line receptacle ..............................................................................................................................................................................................12
RJF CAT6 receptacle with self closing cap .................................................................................................................................................................... 15
RJF plugs with 360° EMI backshell ................................................................................................................................................................................... 16
RJF special plugs for big insulation wire up to 1.6 mm ........................................................................................................................................... 17
RJF TV6 - CAT6 Ethernet connection system for harsh environment ...................................................................................................................18
RJF TV6 - CAT6 through bulkhead receptacles ..............................................................................................................................................................21
RJFTV plugs with 360° EMI backshell ............................................................................................................................................................................. 24
RJFTV special plugs for big insulation wire up to 1.6mm ....................................................................................................................................... 25
Amphenol
4
Self closing cap (SCC) for RJF TV6/RJFTV receptacles .................................................................................................................................................26
High reliability CAT6 Ethernet cable and cordsets .......................................................................................................................................................27
ATEX Solutions
RJF TVX6 - CAT6 RJ45 explosion proof solution for Zone 2 .....................................................................................................................................28
ROHS
RJF RB
COMPLIANT
CAT6 Ethernet connection system for harsh environment – Industrial Ethernet
RJFRB allows you to use an Ethernet Class E / Cat 6 connection for 10 BaseT, 100
BaseTX or 1000 BaseT up to 250 MHz networks in harsh environments.
With the patented RJStop® system you can use a standard RJ45 cordset in a
protective
composite
plug which will protect it from shocks, dust and fluids.
No hazardous on-field cabling and grounding!
Applications
n
Telecom equipments
n
Video control
n
Robotics
n
Industrial process control
n
machines
CNC
n
Special machines
n
Motion control
Main characteristics
n
Sealed against fluids and dust (IP68)
n
Shock, vibration and traction resistant
n
cabling operation in field, no tools required
No
n
Reverse bayonet coupling
n
cordset retention in the plug: 70 N in the axis
RJ45
n
Mating cycles: 500 min
n
Compatible with cable diameter from 5,5 mm [0.216 in] to 7 mm [0.275 in]
Environmental protection
n
Sealing: IP68
n
spray > 1000 h
Salt
n
retardant / Low smoke: UL94 V0 and NFF 16102, DIN 5510-2
Fire
n
Thermal shock: 5 cycles at - 40°C / +100°C
n
Operating temperature: - 40°C / +85°C
Data transmission
10 BaseT, 100 BaseTX and 1000 BaseT up to 250
MHz networks
Cat6 per EIA/TIA 568 and ClassE per ISO11801
Part number code
RJF RB
Shell type
7:
composite jam nut receptacle
6:
composite reverse bayonet plug, plastic gland
Back terminations
(for receptacles only)
3U:
IDC cat6 - unshielded
3F:
IDC cat6 - partial shielding
3S:
IDC cat6 - 100% shielded
Examples:
- receptacle, IDC cat6, unshielded
RJF RB 73U
- plug
RJF RB 6
7
3U
Receptacle
n
3: IDC CAT 6 termination (rear mounting)
Type
Panel Drilling
Unshielded:
RJF RB 73U
Partial shielding
RJF RB 73F
Shielded:
RJFRB73S
Cat5e version: page 10 of the Field series catalogue.
I recently started playing with Multi_Touch LCD. The CD that came with this touch screen said that I first had to download the image into FLASH. The download method was through the Control Panel. But ...
c51 is connected to pc through 485-232 port. I can't debug it for the first time. I want the computer to send a number and the microcontroller returns a number. I use the serial port assistant. Please...
Beijing Automotive Research Institute Co., Ltd. is an enterprise based on the research and development of independent brand automobile technology. Due to project needs, it is now urgently recruiting t...
FPGA and PCB collaborative design solution: We know that after the FPGA function development is completed, the corresponding functional circuit board must be developed. In PCB design, a lot of repetit...
1. Introduction
This design was made for participating in an electronic design competition. It effectively solved the problem of the operation and control of an electric car on a seesaw. The s...[Details]
With the advent of increasingly powerful processors, image sensors, memory, and other semiconductor devices, as well as the algorithms that enable them, computer vision can be implemented in a wide...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
With concerns about the growing energy crisis, motor efficiency has become an important and timely topic. This is because motors use 63% to 70% of the electricity produced in the United States and ...[Details]
As people's requirements for safety and comfort in the process of driving cars continue to increase, automotive radars are widely used in the car's adaptive cruise system, collision avoidance syste...[Details]
The TPS92210 is a single-stage LED lighting pulse width modulation (PWM) controller. The TRIAC dimmable solution not only regulates the LED current, but also achieves a power factor close to 1. The...[Details]
store
To prevent moisture, LEDs should be stored in a dry and ventilated environment with a storage temperature of -40°C to +100°C and a relative humidity below 85%.
The LED should be use...[Details]
Car lights, whether headlights, fog lights or tail lights, play an important role in driving safety. However, the material of the car lights determines that the probability of damage in a collision...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
The power consumption of a switching power supply includes fixed losses caused by parasitic resistances such as semiconductor switches, magnetic components, and wiring, as well as switching losses ...[Details]
introduction
Caller ID delivery (CID) is a service provided to the user's phone. The method is that the originating switch transmits the caller number and other information to the terminal swi...[Details]