IEC Inlet Filters FN 9244 E
Excellent Performance EMC/EMI Filter with Earth Line Choke
Rated currents up to 15 A
Superior attenuation performance
Integrated earth line choke
Complies with IEC/EN 60601-1
Snap-in versions (S and S1 type)
Hot inlet versions (HI type)
Approvals
(CQC except HI-types)
Performance indicators
The FN 9244 E IEC inlet filter combines an IEC inlet
and mains filter with superior filter attenuation in a
small form factor. The FN 9244 E high performance
power entry module offers additional EMI
suppression on the earth line. Choosing the FN 9244
E product line brings you the rapid availability of a
standard filter associated with the necessary safety
acceptances. Standard IEC connector filters are a
practical solution helping you to pass EMI system
approval in a short time. A wide selection on
amperage ratings, output connections, mounting
possibilities and filters for medical applications are
designed to offer you the desired solution. For types
without additional earth line choke please consult
the FN 9244 data sheet.
Technical specifications
Maximum continuous operating voltage
Operating frequency
Rated currents
Approvals by rated current
High potential test voltage
250 VAC, 50/60 Hz
dc to 400 Hz
1 to 15 A @ 50°C
1 to 10 A (ENEC, CQC)
1 to 15 A (UL, CSA)
P –> PE 2000 VAC for 2 sec (standard types)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 1000 VAC for 2 sec
IP 40 according to IEC 60529
-25°C to +85°C (25/85/21)
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
UL 94 V-2 or better
2,230,000 hours
Features and benefits
Superior conducted attenuation performance,
based on chokes with high saturation resistance
and excellent thermal behavior
Rear/front or snap-in mounting
Without earth line choke see FN 9244 data sheet
Optional medical versions (B type) comply with the
requirements of IEC/EN 60601-1 for creepage and
clearance, leakage current and high potential
testing
Wide mounting flanges available
Custom-specific versions are available on request
Protection category
Temperature range (operation and storage)
Design corresponding to
Flammability corresponding to
MTBF @ 40°C/230 V (Mil-HB-217F)
Typical applications
Electrical and electronic equipment
Small to medium-sized machines and household
equipment
Single-phase power supplies, switch-mode power
supplies
Test and measurement equipment
Medical devices (MDD)
In-vitro diagnostic medical devices (IVDD)
Rack mounting equipment
Typical electrical schematic
DIY emergency light accessories are available~~
The picture aboveSpecial thanks to Simon:), under Simon's guidance, we wandered around Zhongfa and Zhichun for more than 2 hours and finally got all the devices....
soso DIY/Open Source Hardware
Three-terminal regulator data
Three-terminal regulator data...
hxiaoruo Analog electronics
[Q&A] Which one has higher precision, a stepper motor or a servo motor?
[size=4]Some friends may ask, why did Lao Xu ask this question? Electricians all know that servo motors are definitely more accurate than stepper motors! [/size] [size=4] [/size] [size=4]As we all kno...
xuyiyi Integrated technical exchanges
05.11 DIY home IoT terminal: initial framework of basic functions, looking forward to suggestions!
Netizens who participate in the DIY activity of home IoT terminals please note:The above is the basic framework of this project in its early stages. If there are any functions that need to be added, p...
EEWORLD社区 DIY/Open Source Hardware
Question + How to implement automatic ISP on power-on in STM32
We all know that the ISP of stm32 must pull up BOOT0. Does anyone have any good way to pull up boot0 without opening the shell, but achieve it through restart....
zhaojun_xf stm32/stm8
Selection of winning works of the 5th National Undergraduate Electronic Design Competition
Selection of winning works of the 5th National Undergraduate Electronic Design Competition...
wqd520 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2586  2223  1768  629  1963  53  45  36  13  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号