P4056
Description
Pressure Transducer
The P4056 Pressure Transducer incorporate a back-side PRT configuration that is compatible with many types of liquid and gaseous media. This flexible
product family can be supplied with a built in Metri-Pack 150 electrical connector. The small sensor size is ideal for high volume applications. Pressure
ranges may be customized for OEM applications. The P4056 pressure ranges are measured in Bar.
Features
• Small Size
• Absolute, Gage or Sealed Gage Pressure References
• Packard Metri-Pack 150 Electrical Connector Standard
• 0.5 to 4.5 Vdc Output
• High Vibration Tolerance
• Superior EMI/RFI Performance
• Available with NPT, G1/4, M10, & M12 Pressure Ports
• Temperature Compensated
• RoHS Compliant
Applications
• Pumps & Compressors
• Process Controls
• Filter Restriction
• Oil and Fuel Pressures
• Water Management
• Level Measurement
• Test & Monitoring Equipment
MAIN FEATURES
Pressure Ranges
Electrical Connection
Pressure Connection
Housing Material
Output Signal
0 to 200 mBar up to 0 to 20 bar
Packard Electric Metri-Pack 150 Series
1/4-18 NPT (external), 1/8-27 NPT (external) - for more options see how to order
Brass
0.5 - 4.5 VDC
Page 1
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
TECHNICAL SPECIFICATIONS
Pressure Ranges
From 0 to ...
*1
Proof Pressure
Burst Pressure
bar
bar
bar
200 mBar
400 mBar
600 mBar
300 mBar
600 mBar
900 mBar
1
2
3
2
4
6
4
8
12
5
10
15
7
14
21
10
20
30
15
22.5
30
20
30
40
1. for more options see Ordering Options
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Media Temperature
Environmental Temperature
Storage Temperature
Media
min. 10 million full pressure cycles over the full range
10 G’s peak to peak sinusoidal, from 20 to 2000 Hz
75 G’s ½ sine wave
1m onto concrete surface
≤
50 grams
IP67
-40°C to + 125°C
-40°C to + 125°C
-40°C to + 125°C
All class II fluids and gases compatible with brass and fluorosilicone
Performance
Total Error Band
2
+/-2% of span (-20
≤
T
≤
100° C) +/-3% of span (T < -20° C,T < 100° C)
2. Including accuracy, calibration, temperature, non-linearity, hysteresis, non-repeatability, error
Electrical
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Reverse Polarity Protection
Impedance
Response Time
3. for min. 3 intervals at 5 minutes each
4. for min. 10 seconds on assigned pins
0.5…4.5 VDC ratiometric
5 VDC ± 5%
≤
25 mW
16 VDC
Yes
3
500 VDC
Yes
4
Min load 25 kΩ
≤
10 ms max. to 63% of full scale pressure with step change on input
Page 2
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
DIMENSIONS
Dimensions in mm [Inch]
Packard (metri-pack 150) Pin Call Outs
Output
0.5-4.5 VDC ratiometric
Pin A
GND
Pin B
Vsup
Pin C
Vout
Page 3
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
ORDERING OPTIONS
Example: P4056-15A-E1A
P4056 Pressure Sensor, 0 – 1 Bar Absolute, Fluorosolicone Internal
Sealrmaterial , 1/4-18 NPT- Pressure Connection, with Packard Metri-Pack 150
Built-in Connector
Family
P4056
P4056
15
A
E
1
A
Pressure Ranges
P2:
P3:
1:
2:
4:
5:
7:
10:
14:
15:
16:
20:
0 - 200 mBar
0 - 300 mBar
0 - 1 Bar
0 - 2 Bar
0 - 4 Bar
0 - 5 Bar
0 - 7 Bar
0 - 10 Bar
0 - 14 Bar
0 - 15 Bar
0 - 16 Bar
0 - 20 Bar
Reference
A:
Absolute
G:
Gauge
S:
Sealed Gauge
Internal Seal Material
E:
Fluorosilicone
Pressure Connection (Port)
1:
1/4-18 NPT
2:
M12 X 1.5-6g PER ISO 6149
3:
M10 X 1-6g PER ISO 6149
4:
1/8-27 NPTF
5:
STUD END PER DIN 3852-A-G1/4 (sealing by washer, not supplied)
6:
M14 X 1.5-6g PER ISO 6149
7:
STUD END PER DIN 3852-C-R1/4 (1/4-19 BSPT)
8:
7/16-20UNF-2A
9:
M16 X 1.5-6g
10:
STUD END PER DIN 3852-C-R1/8 (1/8-28 BSPT)
Built-in Connector
A:
Metripack 150 with mating connector 12” leads
C:
Metripack 150 without mating connector
Page 4
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
AGENCY APPROVALS & CERTIFICATIONS
2002/95/EC RoHS Directive
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B) and Immunity (industrial locations), EMI, ESD
protected
Page 5
Revised 2/7/18
Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that
incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible
for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have
been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that
specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements,
improvements and other changes to its data sheets or components without notice.
Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO
OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND
NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS
ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE
OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS
ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET
ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD
TO SENSATA DATA SHEETS OR USE THEREOF.
All products are sold subject to Sensata’s terms and conditions of sale supplied at
www.sensata.com
SENSATA ASSUMES NO LIABILITY
FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY
RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS,
AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION
OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.
Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA.
CONTACT US
Americas
+1 (800) 350 2727
sensors@sensata.com
switches@sensata.com
Europe, Middle East & Africa
+359 (2) 809 1826
pressure-info.eu@sensata.com
Asia Pacific
sales.isasia@list.sensata.com
China
+86 (21) 2306 1500
Japan
+81 (45) 277 7117
Korea
+82 (31) 601 2004
India
+91 (80) 67920890
Rest of Asia
+886 (2) 27602006
ext 2808
Copyright © 2018 Sensata Technologies, Inc.