EEWORLDEEWORLDEEWORLD

Part Number

Search

325438EP028

Description
Power/Signal Relay, 4 Form C, 4PDT, Momentary, 12.5A (Coil), 32VDC (Coil), 3A (Contact), 28VDC (Contact), DC Input, Random, AC/DC Output, Panel Mount
CategoryMechanical and electronic products    relay   
File Size335KB,4 Pages
ManufacturerSTPI Siege Social
Download Datasheet Parametric View All

325438EP028 Overview

Power/Signal Relay, 4 Form C, 4PDT, Momentary, 12.5A (Coil), 32VDC (Coil), 3A (Contact), 28VDC (Contact), DC Input, Random, AC/DC Output, Panel Mount

325438EP028 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
body width20.6 mm
body height16.3 mm
Body length or diameter20.6 mm
Maximum coil current (DC)12.5 A
Coil operating voltage (DC)19.8 V
Coil release voltage (DC)1.5 V
Coil resistance400 Ω
Maximum coil voltage (DC)32 V
Nominal coil voltage28 V
Coil/Input Power TypeDC
Contact (AC) maximum rated load I5A@115VAC
Contact (AC) maximum rated load M2A@115VAC
Contact (AC) maximum rated R load5A@115VAC
Maximum contact current (AC)5 A
Maximum contact current (DC)3 A
Contact (DC) maximum rated R load3A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
Input switching control typeRandom
Insulation resistance100000000 Ω
JESD-609 codee3
Manufacturer's serial number325
Installation featuresPANEL MOUNT
Number of terminals14
operating hours16 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
physical size20.6mm X 20.6mm X 16.3mm
Relay actionMOMENTARY
Relay style4 FORM C
Relay function4PDT
Relay typePOWER/SIGNAL RELAY
release time26 ms
sealHERMETICALLY SEALED
surface mountNO
Terminal surfaceTIN
Terminal length0.0053 inch
Termination typeSOLDER HOOK
weight33 g
Base Number Matches1
325 4
RT -
4
PDT
/5
A
RELAIS HERMETIQUES
MONOSTABLES
HERMETICALLY SEALED
NON LATCHING
RELAY
CARACTERISTIQUES GENERALES
GENERAL CHARACTERICS
Combinaison des contacts
Contact arrangement
4 RT
4 PDT
Pouvoir de coupure 28 Vcc - 1 5 /200 V - 400 Hz
1
Contact rating 28 Vdc - 115 V/400 Hz
Circuit résistif
Resistive load
5A
5 Amps
Circuit inductif (L/R = 5 ms)
Inductive load (L/R = 5 ms)
3 A (28 Vcc) / 5 A (1 5 V - 400 Hz)
1
3 Amps (28 Vdc) / 5 Amps (115 V - 400 Hz)
Circuit moteur
Motor load
2A
2 Amps
Circuit lampe
Lamp load
1A
1 Amp
Alimentation
Supply
Courant continu (polarisé) ou courant alternatif (400 Hz)
Direct current (polarised) or alternative current (400 Hz)
Masse
Weight
27 g à 33 g max.
27 g to 33 g max.
Normes applicables en annexe
See appendice for applicable specifications
ENVIRONNEMENT
Température de fonctionnement
Temperature range
ENVIRONMENT
- 65° à + 1
25°C
- 65° to + 125°C
Position de fonctionnement
Operating position
Indifférente
Any
Tenue aux vibrations
Resistance against vibrations
Sinus : 30 g - 70 - 3 000 Hz / Aléatoire : 0,4 g
2
/Hz - 50 - 2 000 Hz
Sinus : 30 g - 70 - 3 000 Hz / Random : 0,4 g
2
/Hz - 50 - 2 000 Hz
Tenue aux chocs
Shocks resistance
200 g - 6 ms
200 g - 6 ms
Tenue aux secousses
Shake resistance
40 g
40 g
Accélération
Acceleration
20 g
20 g
Taux de fuite
Leak rate
1.10
-8
cm
3
/sec
1.10
-8
cm
3
/sec
58 Av. Claude VELLEFAUX - 75010 PARIS - FRANCE
325 1/4
35
Tel : 33.(0)1.42.03.94.20 - Fax : 33.(0)1.42.03.52.85 - www.stpigroup.com
Has anyone tried ce6.0 rc3?
I saw a lot of interesting things. The original BSP under RC2 should not need to be modified, right? Has anyone tried IE and Flash? How about gesture recognition?...
rtl84723 Embedded System
Application of USB interface in information appliances
Application of USB interface in information appliances...
open82977352 Appliance Repair Collection
sampling
May I ask how the experts in the group achieve multiple sampling in one PWM cycle?...
lzx_18570633112 DSP and ARM Processors
Electric energy measurement solution based on C2000 built-in 12-bit ADC
This application note introduces a solution to implement software energy metering based on the C2000 core and the on-chip 12-bit ADC. C2000 is a 32-bit high-performance real-time microcontroller produ...
fish001 Microcontroller MCU
Q: LM3S control circuit is isolated from the main circuit
What methods are generally used, dear......
喜鹊王子 Microcontroller MCU
The role of leakage protector
Installing a leakage protector in a low-voltage power distribution system is one of the effective measures to prevent personal electric shock accidents, and it is also a technical measure to prevent e...
eeleader Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1571  1854  2707  2801  2655  32  38  55  57  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号