EEWORLDEEWORLDEEWORLD

Part Number

Search

SUCW1R54812BP

Description
Isolated DC/DC Converters 1.5W 12/24V 0.65A SMD/SMT
Categorysemiconductor    Power management   
File Size564KB,9 Pages
ManufacturerCosel
Download Datasheet Parametric View All

SUCW1R54812BP Online Shopping

Suppliers Part Number Price MOQ In stock  
SUCW1R54812BP - - View Buy Now

SUCW1R54812BP Overview

Isolated DC/DC Converters 1.5W 12/24V 0.65A SMD/SMT

SUCW1R54812BP Parametric

Parameter NameAttribute value
Product CategoryIsolated DC/DC Converters
ManufacturerCosel
RoHSDetails
Number of Outputs2 Output
Output Power1.5 W
Input Voltage36 V to 76 V
Output Voltage-Channel 112 V
Output Current-Channel 165 mA
Output Voltage-Channel 224 V
Output Current-Channel 265 mA
Isolation Voltage500 V
Mounting StyleSMD/SMT
Length0.88 in
Width0.52 in
Height0.28 in
Commercial/MedicalCommercial
Operating Temperature Range- 40 C to + 85 C
ProductIsolated
Factory Pack Quantity600
Unit Weight0.105822 oz
DC-DC Converters PCB Mount Type
Ordering information
SUCW1R5
SUC W 1R5 12 12
1
2
3
4
5
6
B
7
P
-O
8
R
1Series
name
2Dual
output
3Output
wattage
4Input
voltage
5Output
voltage
6Mounting
type
B :SMD
C :DIP
7Packing
form
Blank:Plastic cover
P :Tray (SMD type)
8Optional
C :with coating (only DIP
type)*
*
Safety standards are
pending
SU.SUC/SUT
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
SUCW1R50512
1.56
VOLTAGE[V]
*
1
t
12 or +24
CURRENT[A] 0.065
SUCW1R50515
1.5
t
15 or +30
0.05
SUCW1R51212
1.56
t
12 or +24
0.065
SUCW1R51215
1.5
t
15 or +30
0.05
SUCW1R52412
1.56
t
12 or +24
0.065
SUCW1R52415
1.5
t
15 or +30
0.05
SUCW1R54812
1.56
t
12 or +24
0.065
SUCW1R54815
1.5
t
15 or +30
0.05
SPECIFICATIONS
MODEL
VOLTAGE[V]
*
2
CURRENT[A]
INPUT
*
2
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
-20 to +55
C
*
3
RIPPLE[mVp-p]
-40 to -20
C
*
3
-20 to +55
C
*
3
OUTPUT
RIPPLE NOISE[mVp-p]
-40 to -20
C
*
3
-20 to +55
C
TEMPERATURE REGULATION[mV]
-40 to +55
C
*
4
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE
OUTPUT VOLTAGE SETTING[V] (t5%)
OVERCURRENT PROTECTION
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY
AGENCY APPROVALS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
PROTECTION
CIRCUIT AND
OTHERS
SU.SUC/SUT
SUCW1R50512
DC4.5 - 9
0.446typ
70typ
t
12(+24)
SUCW1R50515 SUCW1R51212
DC9 - 18
0.429typ
0.178typ
70typ
73typ
t
15(+30)
t
12(+24)
SUCW1R51215 SUCW1R52412
DC18 - 36
0.171typ
0.089typ
73typ
73typ
t
15(+30)
t
12(+24)
0.05
75max
750max
120max
150max
150max
200max
180max
290max
60max
0.065
60max
600max
120max
150max
150max
200max
150max
240max
50max
SUCW1R52415 SUCW1R54812
DC36 - 76
0.086typ
0.045typ
73typ
73typ
t
15(+30)
t
12(+24)
0.05
75max
750max
120max
150max
150max
200max
180max
290max
60max
0.065
60max
600max
120max
150max
150max
200max
150max
240max
50max
SUCW1R54815
0.043typ
73typ
t
15(+30)
0.05
75max
750max
120max
150max
150max
200max
180max
290max
60max
by external VR
11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75
Works over 105% of rating and recovers automatically
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
AC500V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (20
t
15
C
)
-40 to +85
C
, 20 - 95%RH (Non condensing) (Required Derating), 3,000m (10,000feet) max
-40 to +100
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s
2
(10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s
2
(50G), 11ms, once each along X, Y and Z axis
UL60950-1, C-UL, EN60950-1
22.4
X
7.0
X
13.2mm [0.88
X
0.28
X
0.52 inches] (W
X
H
X
D) / 3g max
Convection/Forced air
0.065
0.05
0.065
60max
75max
60max
600max
750max
600max
120max
120max
120max
150max
150max
150max
150max
150max
150max
200max
200max
200max
150max
180max
150max
240max
290max
240max
50max
60max
50max
20max (Minimum input, Io=100%)
Fixed (TRM pin open)
t
5% adjustable
*1
*2
*3
*4
*
Output pins can be connected in series to make a 24V/30V output.
Rated input 5V, 12V, 24V or 48V DC Io=100%
Ripple and Ripple Noise is measured by using measuring board with capacitor with in 25mm from output pin terminals.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
Parallel operation with other model is not possible.
SU
.SUC/SUT-26
SUC/SUT-26

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1984  1702  1263  2764  1694  40  35  26  56  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号