V12
SPECIFICATIONS
All Specifications Typical At Nominal Line, Full Load, and 25℃ Unless Otherwise Noted
INPUT SPECIFICATIONS :
Input Voltage Range ....……………............................................ ±10%
Input Surge Voltage (100ms max.) ………….. 5V …............ 9Vdc max.
12V …….... 18Vdc max.
24V ….… 30Vdc max.
Input Filter ……………………………………………..……… Capacitive
GENERAL SPECIFICATIONS :
Efficiency ...........................................………..……..…..…............. See Table
Isolation Voltage ...................................……..…………......... 1000 VDC min.
9
Isolation Resistance .....................…….…………..……..……..… 10 ohm min.
Isolation Capacitance …………………..………………………….. 10pF typ.
Switching Frequency ................................ 5&12V Input ........... 90KHz typ.
24V Input ........……. 80KHz typ.
Operating Ambient Temperature Range .....………....….….... -40℃ to +85℃
De-rating, Above 85℃ ……………..….……. Linearly to Zero power at 100℃
Case temperature (note4) ………..………….………..…..…... +100℃ max.
Cooling ……………………………….…..……..….……….. Natural Convection
Storage Temperature Range ...………..........………....…....... -55℃ to +125℃
Humidity .......................................................... 95% RH max. Non condensing
MTBF ………………. MIL-STD-217F, GB ……….…….……….. 1.7Mhrs min.
Dimensions:
5&12V input ..………….….….… 0.46x0.24x0.40 inches(11.6x6.0x10.2 mm)
24V input ………………..…..… 0.46x0.30x0.40 inches(11.6x7.5x10.2 mm)
Case Material ………………………………..… Non-conductive black plastic
Weight ………..………………………...…… 5&12V Input ….…..….….… 1.3g
24V Input ..….……….……. 1.7g
OUTPUT SPECIFICATIONS:
Voltage Accuracy …………………....……………...........… ±3.0% max.
Ripple and Noise, 20MHz BW .......................…….. 100mV pk-pk max.
Temperature Coefficient ................….……………....... ±0.05%/℃
Short Circuit Protection ...................……….… Momentary 1sec.
Line Regulation (note1) .….………...………………….….... ±1.2%
Load Regulation (note2) ………………….............……….... ±10%
max.
max.
max.
max.
Typical Derating curve for Natural Convection
120%
100%
LO AD(%)
80%
60%
40%
20%
0%
-40
-20
0
20
40
60
Ambient Temperature(
o
C)
80
100
Natural
Convection
NOTE :
1. Line regulation is per 1.0% change in input voltage.
2. Load regulation is for load change from 100% to 20%.
3. The output noise is measured with 0.33uF ceramic capacitor.
4. Maximum case temperature under any operating condition should
not be exceeded 100℃.
5. The EC1TA2XN input terminal need to parallel with 4.7uF ceramic
capacitor.
CASE SIP-4:
All Dimensions In Inches (mm)
Tolerances
Inches
Millimeters
±0.01
±0.25
±0.05
Pin
±0.002
0.46 [11.6]
0.40 [10.2]
0.02 [0.5]
PIN CONNECTION
Pin
1
2
3
4
Single
-Vin
+Vin
-Vout
+Vout
0.02 [0.5]
0.08 [2.0]
0.13 [3.2]
0.020 [0.50]
0.100 [2.54]
0.300 [7.62]
0.30 [7.5]
24V Models
0.24 [6.0]
1
2
3
4
0.010 [0.25]
0.07 [1.8]
Bottom View
2