EEWORLDEEWORLDEEWORLD

Part Number

Search

DAS100F24

Description
Heat Sinks HEAT SINK-HORIZONTAL DAS100/DPA500F
CategoryPower/power management    The power supply circuit   
File Size172KB,5 Pages
ManufacturerCosel
Download Datasheet Parametric Compare View All

DAS100F24 Online Shopping

Suppliers Part Number Price MOQ In stock  
DAS100F24 - - View Buy Now

DAS100F24 Overview

Heat Sinks HEAT SINK-HORIZONTAL DAS100/DPA500F

DAS100F24 Parametric

Parameter NameAttribute value
MakerCosel
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
DC-DC Converters Power Module type
Ordering information
DAS50
R
DA
1
2
S
3
50
4
O
5
05
1Series
name
2Single
output
3Output
wattage
4Input
voltage
F :DC88 - 370V
48 :DC36 - 72V
5Output
voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
DAS50F05
50
5V 10A
DAS50F12
50.4
12V 4.2A
DAS50F24
50.4
24V 2.1A
DAS504805
50
5V 10A
DAS504812
50.4
12V 4.2A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
EFFICIENCY[%]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +85
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +85
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +85
C
TEMPERATURE REGULATION[mV]
-10 to +85
C
*
2
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
DAS50F05
DAS50F12
DAS50F24
DC88 - 370
0.5typ (DCIN 130V, Io=100%) 0.25typ (DCIN 260V, Io=100%)
82typ
82typ
82typ
0.3max (By UL, CSA, VDE and DEN-AN)
5
12
24
10
4.2
2.1
20max
48max
96max
40max
100max
150max
80max
120max
120max
140max
160max
160max
150max
200max
200max
190max
230max
230max
85max
204max
408max
95max
228max
456max
20max
48max
96max
200max (DCIN 88V, Io=100%)
Fixed (TRM pin open)
t
10% adjustable by external VR
DAS504805
DAS504812
DC36 - 72
1.30typ (DCIN 48V, Io=100%) 1.28typ (DCIN 48V, Io=100%)
80typ
82typ
5
10
20max
40max
80max
140max
150max
190max
85max
95max
20max
200max (DCIN 36V,
12
4.2
48max
100max
120max
160max
200max
230max
210max
230max
48max
Io=100%)
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
DAS
ENVIRONMENT
SAFETY
OTHERS
4.85 - 5.35
11.4 - 12.6
22.8 - 25.2
4.85 - 5.35
11.4 - 12.6
Works over 105% of rating and recovers automatically
Works at 115 - 140% of rating
Provided
Between RC and -side of input:short - 1.2V
---
output ON, 2.4 - 5.5V(or open)
---
output OFF, Compatible TTL
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA max, DC500V 50M
W
min (At Room Temperature)
-10 to +85
C
(Aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 49.0m/s
2
(5G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with UL60950-1, CSA C22.2 No.60950-1 and EN60950-1
58
X
12.7
X
115mm (W
X
H
X
D) / 120g max
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1
Measured by attaching the electrolytic capacitor of 220mF at output.
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*
Parallel operation with other model is not possible.
DAS-2

DAS100F24 Related Products

DAS100F24 DAS100F05 DAS1004812 DAS50F24 DAS50F12 DAS504812
Description Heat Sinks HEAT SINK-HORIZONTAL DAS100/DPA500F Heat Sinks HEAT SINK-HORIZONTAL DAS100/DPA500F Heat Sinks HEAT SINK-HORIZONTAL DAS100/DPA500F Heat Sinks HEAT SINK-VERTICAL DAS50 SERIES Isolated DC/DC Converters Board mount DC/DC (88-370DC IN) Isolated DC/DC Converters Board mount DC/DC (36-72DC IN)
Product Category - - Isolated DC/DC Converters Isolated DC/DC Converters Isolated DC/DC Converters Isolated DC/DC Converters
Manufacturer - - Cosel Cosel Cosel Cosel
RoHS - - Details Details Details Details
Number of Outputs - - 1 Output 1 Output 1 Output 1 Output
Output Voltage-Channel 1 - - 12 V 24 V 12 V 12 V
Output Current-Channel 1 - - 8.5 A 2.1 A 4.2 A 4.2 A
Isolation Voltage - - 3 kVAC/500 VDC 3 kVAC/500 VDC 3 kVAC/500 VDC 3 kVAC/500 VDC
Mounting Style - - SMD/SMT SMD/SMT SMD/SMT SMD/SMT
Length - - 130 mm 115 mm 115 mm 115 mm
Width - - 58 mm 12.7 mm 12.7 mm 12.7 mm
Height - - 12.7 mm 58 mm 58 mm 58 mm
Factory Pack Quantity - - 100 100 100 100
Unit Weight - - 5.291094 oz 4.232875 oz 4.232875 oz 4.232875 oz

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2074  238  1598  494  1712  42  5  33  10  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号