EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-J6M-MZ-B1

Description
Isolated DC/DC Converters VI J00/200 - 300 Vin, 10 Vout, 25 W, M Product Grade
CategoryPower/power management    The power supply circuit   
File Size655KB,8 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-J6M-MZ-B1 Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-J6M-MZ-B1 - - View Buy Now

VI-J6M-MZ-B1 Overview

Isolated DC/DC Converters VI J00/200 - 300 Vin, 10 Vout, 25 W, M Product Grade

VI-J6M-MZ-B1 Parametric

Parameter NameAttribute value
MakerVICOR
package instruction,
Reach Compliance Codecompliant
Other featuresREMOTE SHUTDOWN
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
CertificationTUV, UL
Efficiency (main output)90%
high27.4 mm
Maximum input voltage400 V
Minimum input voltage200 V
Nominal input voltage300 V
length61 mm
Maximum grid adjustment rate0.2%
Maximum load regulation0.2%
Maximum operating temperature100 °C
Minimum operating temperature-55 °C
Nominal output voltage10 V
Maximum total power output25 W
width57.9 mm
Half Brick, DC-DC Converters
VI-J00
VE-J00
®
S
C
US
C
NRTL
US
25 to 100 Watts
Features & Benefits
Isolated output
Up to 50W/in
3
cURus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28” x 2.4” x 0.5”
(57,9 x 61,0 x 12,7mm)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
RoHS compliant (VE verisons)
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC
converters. This “junior” size complement to the higher power VI-200 family offers up
to 100W of isolated and regulated power in a board mounted package. With thousands
of input/output/power combinations, and with a maximum operating temperature
rating of 100°C, the MiniMod provides nearly unlimited flexibiliy for power system
designers to meet demanding time to market requirements.
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven
by an installed base of over 8 million units, the MiniMod family combines state of
the art power density with the efficiency, low noise and reliability required by next
generation power systems.
Part Numbering
VI
J
6
1
C
W
Family
VI
=Non-RoHS
VE
= RoHS
Series
J
= J00
0
= 12V
V
= 24V
1
= 24V
W
= 24V
2
= 36V
3
= 48V
Input
N
= 48V
4
= 72V
T
= 110V
5
= 150V
6
= 300V
7
= 150/300V
Z
= 2V
Y
= 3.3V
0
= 5V
X
= 5.2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
Output
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
Grade
E
= –10 to 100°C
I
= – 40 to 100°C
M
= –55 to 100°C
≥ 5V
Power
< 5V
W
= 20A
X
= 15A
Y
= 10A
Z
= 5A
C
= –25 to 100°C
W
= 100W
X
= 75W
Y
= 50W
Z
= 25W
Note:
For additional
packaging options,
please see page 5.
VI-J00 DC-DC Converters
Page 1 of 7
Rev 3.0
06/2017
Ask for advice on multi-point measurement in the weighing industry
I would like to ask experts for advice on the problem of multi-point measurement in the weighing industry. As shown in the figure below, pressure sensors are installed at the four corners of the table...
simonprince Microcontroller MCU
RC π type filter resistor and capacitor value -------
RC π-type filter resistor and capacitor value ---Some people say that according to experience, 2πfR or 2πfc or 2πfl is less than (switching frequency 1M) * 1/5 or 1/10? In the formula, f is the switch...
QWE4562009 Discrete Device
How to achieve analog/digital conversion?
I am making a detection device that needs to convert current or voltage signals into digital signals and output them on a PC. I would like to ask experts how to achieve this. The more specific the bet...
lqdz68 Embedded System
A/D conversion: Relationship between conversion frequency and sampling frequency?
A/D conversion: the relationship between conversion frequency and sampling frequency? Please tell me what is the relationship between the two. I feel confused....
Grizabella Analog electronics
A new trend of green power: fuel cells
With the shortage of energy, rising oil prices and serious environmental pollution, energy conservation and environmental protection have become the direction of human unremitting efforts. Fuel cells ...
clj2004000 Power technology
Talk about the usage of function pointers
[size=4][color=#000000]When the program is running, the function code is the algorithm instruction part of the program. Like arrays, they also occupy storage space and have corresponding addresses. Yo...
Aguilera Programming Basics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1366  2757  2319  1791  1530  28  56  47  37  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号