Industrial and process control, distributed power, medical, ATE, communications,
defense, and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V24B12T200BL2
24B
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
P
OUT
100W, 150W
150W, 200W
200W
200W
150W, 200W, 250W
150W, 200W
150W, 200W, 250W
150W, 200W, 250W
150W, 200W
150W, 200W, 250W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
6.5
= 6.5V
8
=
8V
12
=
12V
15
=
15V
24
=
24V
28
=
28V
36
=
36V
48
=
48V
V
OUT
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36 V
48 V
24V Mini Family
Page 1 of 15
Rev 5.1
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
%/°C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 9.1
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Mini Family
Page 2 of 15
Rev 5.1
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
(89.3)
3.5
(99.6)
100
3000
1500
500
10
3.5
(100.3)
3.9
(110.6)
115
cURus, cTÜVus, CE
3.9
(111.3)
4.3
(121.6)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
24V Mini Family
Page 3 of 15
Rev 5.1
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 150W (e.g. S24B3V3C150BL, V24B3V3C150BL)
Parameter
Efficiency
S24B3V3C150BL (enhanced efficiency)
V24B3V3C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
80.0
4.14
Typ
86.5
81.4
160
4.3
5
±0.02
52.3
52.3
Max
Unit
%
200
4.46
6
±0.2
45.45
61.5
61.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
46.4
31.8
3.3
V
OUT
, 100W (e.g. S24B3V3C100BL, V24B3V3C100BL)
Parameter
Efficiency
S24B3V3C100BL (enhanced efficiency)
V24B3V3C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
80.4
4.14
Typ
85.1
81.4
71
4.3
2.5
±0.02
34.8
34.8
Max
Unit
%
89
4.46
3
±0.2
30.3
41
41
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.9
21.2
5
V
OUT
, 200W (e.g. S24B5C200BL, V24B5C200BL)
Parameter
Efficiency
S24B5C200BL (enhanced efficiency)
V24B5C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.9
80.5
6.07
Typ
87.0
84.9
95
6.3
5.1
±0.02
52
52
Max
Unit
%
119
6.53
5.5
±0.45
40
54.5
62
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
40.8
28
5
V
OUT
, 150W (e.g. S24B5C150BL, V24B5C150BL)
Parameter
Efficiency
S24B5C150BL (enhanced efficiency)
V24B5C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
83.5
6.03
Typ
87.2
84.8
50
6.25
3.7
±0.02
34.5
34.5
Max
Unit
Notes
%
63
6.47
4.5
±0.2
30
40.5
40.5
mV
Volts
Watts
%
Amps
Amps
Amps
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.6
5
24V Mini Family
Page 4 of 15
Rev 5.1
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
6.5
V
OUT
, 200W (e.g. S24B6V5C200BL, V24B6V5C200BL)
Parameter
Efficiency
S24B6V5C200BL (enhanced efficiency)
V24B6V5C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.5
83.2
7.7
Typ
87.5
84.6
182
8.0
5.3
±0.02
35.4
35.4
Max
Unit
%
230
8.3
6.2
±0.2
30.8
41.5
41.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
31.4
21.5
8
V
OUT
, 200W (e.g. S24B8C200BL, V24B8C200BL)
Parameter
Efficiency
S24B8C200BL (enhanced efficiency)
V24B8C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.0
85.0
9.36
Typ
89.0
86.4
200
9.7
5
±0.02
28.8
28.8
Max
Unit
%
250
10.1
6
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
12
V
OUT
, 250W (e.g. S24B12C250BL, V24B12C250BL)
Parameter
Efficiency
S24B12C250BL (enhanced efficiency)
V24B12C250BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.0
86.0
13.8
Typ
89.0
87.4
172
14.3
6.5
±0.02
24.0
24.0
Max
Unit
%
215
14.8
7.6
±0.2
20.8
28.1
28.1
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
21.3
14.6
12
V
OUT
, 200W (e.g. S24B12C200BL, V24B12C200BL)
Parameter
Efficiency
S24B12C200BL (enhanced efficiency)
V24B12C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.0
87.0
13.8
Typ
90.0
88.0
360
14.4
4.6
±0.02
19.2
19.2
Max
Unit
%
450
15
7.4
±0.2
16.67
22.6
22.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
DAC function details 1. DAC buffer operation The buffer size is 1~16 and can be set in word units. When converting, the read pointer points to the data being converted. The buffer unit currently being...
The GAPP layer always plays one of the following four roles:
1. Broadcaster - cannot connect to advertising devices
2. Observer - scans broadcasts but cannot initiate connections
3. Peripheral - a con...
DaVinciTM technology DSP TMS320DM648 is based on TI's TMS320C64X+TM DSP core, and is based on TMS320DM642. The new processors integrate new features and reduce video system bill of materials (BOM) cos...
Interrupts largely reflect the performance of a microcontroller. From this point of view, MSP430 does a very good job in interrupts, mainly by providing a very rich interrupt source, the basic ones ar...
Microcontrollers (MCUs), which are widely used in automotive electronics, are rapidly facing time and cost pressures. The main advantage of using MCUs has always been to create high-level system in...[Details]
As cellular phones become more advanced, the power consumption of the system during operation and the power consumption during standby are also increasing. Therefore, the power management design of...[Details]
With the continuous improvement of the requirements of intelligent building security systems and the continuous improvement of people's safety awareness, indoor anti-theft has gradually attracted peop...[Details]
Vertical cavity surface emitting lasers (VCSELs) are gradually replacing traditional edge emitting lasers, especially in low bandwidth and short-distance communication systems where cost factors ar...[Details]
LED technology has made rapid progress, and improvements in chip design and materials have promoted the development of brighter and more durable light sources, and the scope of light source applica...[Details]
1 Introduction
Ultrasound refers to elastic vibration with a frequency higher than the audible frequency limit (i.e., in the frequency band above 20 kHz). The propagation process of this vib...[Details]
The power consumption of a switching power supply includes fixed losses caused by parasitic resistances such as semiconductor switches, magnetic components, and wiring, as well as switching losses ...[Details]
With the popularity of digital appliances, rechargeable batteries can be seen everywhere in people's daily lives and have become one of the indispensable daily necessities.
This article gives ...[Details]
0 Introduction
With the rapid development of modern power electronics technology, various power electronic devices have been widely used in various fields such as power systems, industry, an...[Details]
0 Introduction
PROFIBUS is an open digital communication system with a wide range of applications, which has been included in the international standards IEC 61158 and IEC 61784. Since the gen...[Details]
Stepper motors, also called steppers, use the principles of electromagnetism to convert electrical energy into mechanical energy and have been used since the 1920s. With the increasing popularity o...[Details]
Globally, the market for airbags and other restraint systems consists of different geographical regions, each with its own characteristics and needs. North America first introduced airbags in mass-...[Details]
Current sensing in automotive applications includes controlling the current through solenoids and injectors. For example, during diesel injection, we rapidly increase the current to the induction i...[Details]
1 Causes of problems with electric vehicle batteries
1.1 Caused by the battery itself
Why do we say that? In the previous issue, we learned about the working princi...[Details]
Lithium iron phosphate batteries are used as lithium-ion secondary batteries. Their main application is now in power batteries, which have great advantages over NI-H and Ni-Cd batteries.
Lithi...[Details]