Part Number

Search

389FXCXC1M-24D

Description
General Purpose Relays 389F Power Relay 3PDT, 20A
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size655KB,4 Pages
ManufacturerSCHNEIDER ELECTRIC
Download Datasheet Parametric View All

389FXCXC1M-24D Online Shopping

Suppliers Part Number Price MOQ In stock  
389FXCXC1M-24D - - View Buy Now

389FXCXC1M-24D Overview

General Purpose Relays 389F Power Relay 3PDT, 20A

389FXCXC1M-24D Parametric

Parameter NameAttribute value
Product CategoryGeneral Purpose Relays
ManufacturerSCHNEIDER ELECTRIC
RoHSIn Transition
ProductPower Relay
TypeStandard
Coil Voltage24 VDC
Contact Form3PDT (3 Form C)
Contact Current Rating20 A
Contact TerminationQuick Connect Terminal
Mounting StylePanel
Mounting TypeFlange
Switching Voltage300 VAC
Coil TerminationQuick Connect Terminal
Coil TypeNon-Latching
Coil Resistance400 Ohms
Contact MaterialSilver (Ag)
Power Consumption1.44 W
Factory Pack Quantity100
Unit Weight3.351026 oz
389F Power Relays/One,
Two or Three Pole 20-30 Amp Rating (DC and AC)
Oversized current carrying parts
to run cooler and last longer
Full range of contact ratings
to meet a wide variety of
applications
A variety of covers and
mounting options
Up to 30A switching for
power applications
600 V spacing can handle
most loads
Terminals for 0.25”
Quick Connects
Can be customized for
unique situations
WHITE
UL Recognized
File No. E43641
Contact Viewing Window
Gold Flashed Contacts
Square Base
General Specifications - (UL 508)
Contact Characteristics
Number and type of contacts
Contact materials
Thermal (carrying) current
Maximum switching voltage
Resistive
Switching current @
voltage
Ballast
HP
389FHXX, XHX
SPST-NO-DM, SPDT-DM-DB
Silver Alloy
30 A
600 V
30 A @ 300 VAC 50/60Hz
30 A @ 28 VDC
25 A @ 277 VAC 50/60Hz
1.5 @ 200-300 V 50/60Hz
1 @ 120-199 V 50/60Hz
A600
100 mA @ 5 VDC or 0.5 W
12 to 240 VAC
12 to 110 VDC
85% to 110% AC
80% to 110% DC
3.5 VA
1.44 W
10% AC/DC
100,000 operations
5,000,000 operations
20 ms
2000 VAC
2000 VAC
500 VAC
UL, CE, CSA
-40 to 85 °C
-40 to 55 °C
88 g
389FXAX, BXX, XBX
SPST, SPDT, DPST, DPDT
Silver Alloy
25 A
600 V
25 A @ 300 VAC 50/60Hz
13 A @ 28 VDC
20 A @ 277 VAC 50/60Hz
1.5 @ 208-240 V 50/60Hz
1 @ 480-600 V 50/60Hz
B600
100 mA @ 5 VDC or 0.5 W
12 to 240 VAC
12 to 110 VDC
85% to 110% AC
80% to 110% DC
3.5 VA
1.44 W
10% AC/DC
100,000 operations
5,000,000 operations
20 ms
2000 VAC
2000 VAC
500 VAC
UL, CE, CSA
-40 to 85 °C
-40 to 55 °C
88 g
389FCXX, XCX
3PST, 3PDT
Silver Alloy
20 A
300 V
20 A @ 150 VAC 50/60Hz
13 A @ 28 VDC
20 A @ 150 VAC 50/60Hz
6.67 A @ 277 VAC 50/60Hz
0.5 @ 208-240 V 50/60Hz
0.5 @ 120 V 50/60Hz
B300
100 mA @ 5 VDC or 0.5 W
12 to 240 VAC
12 to 110 VDC
85% to 110% AC
80% to 110% DC
3.5 VA
1.44 W
10% AC/DC
100,000 operations
5,000,000 operations
20 ms
2000 VAC
2000 VAC
500 VAC
UL, CE, CSA
-40 to 85 °C
-40 to 55 °C
88 g
Pilot Duty
Minimum switching requirement
Coil Characteristics
Voltage range
Operating range (% of nominal)
Average consumption
Drop-out voltage threshold
Performance Characteristics
Electrical life (operations @ rated current)
Mechanical life (unpowered)
Operating time (response time)
Between coil and
contact
Dielectric strength
Between poles
Between contacts
Environment
Product certifications
Standard version
Ambient air temperature Storage
around the device
Operation
Weight
SECTION 6
Part Number Builder
389F
Series
389F =
Standard model
equipped with flag indicator
XBX
Configuration
XAX =
SPDT
BXX =
DPST-NO
XBX =
DPDT
CXX =
3PST-NO
XCX =
3PDT
HXX =
SPST-NO-DM
XHX =
SPDT-DM-DB
C1M
Options**
B =
Mounting base
C =
Plastic dust cover - socket mountable
C1 =
Side flange mount cover
C3 =
Top flange cover
L =
Indicator lamp across coil
M =
Manual operator button on case
T =
Printed circuit board terminals
-120
Voltage
Coil Voltage
A
Current Type
A =
AC
D =
DC
Note - Not all iterations of option codes are available and some standard parts may use different nomenclature than outlined in part number builder.
**Multiple codes may be used.
6/12
M a gn e c r a ft S o lu t io n G ui de 1 0 5 A
Supply voltage prevention issues
The power supply line in a certain country adopts a three-phase five-wire system with an ungrounded neutral point. The neutral point is directly drawn from the transformer. When the three-phase load i...
eeleader Industrial Control Electronics
Firmware-based MSP430 programming style, more in-depth discussion to come!
The firmware-based development model has been widely used in ARM Cortex applications. Can MSP430 also adopt this method? The answer is yes. The following is a routine code snippet based on the firmwar...
平湖秋月 Microcontroller MCU
Communication problem between 430 MCU and G100
Thanks for the help: My 430 serial port has been tuned, and G100 is also easy to use with the serial port debugging assistant, but it doesn't work when I use 430 to send commands to G100. What's wrong...
dmj2168 Microcontroller MCU
Urgently looking for PIC16F73B pin description
Please help! Does anyone have the pinout description for the PIC16F73B?...
nwf1987 Microchip MCU
Ask the prawns a question
How to measure the real-time wireless transmission rate when using MSP430f149 and nrf24L01 to realize wireless transmission? I wanted to use the serial port assistant to display the number of received...
kaka0202 Microcontroller MCU
About the issue of Youlong bootloader
Hello everyone! I am learning to transplant bootloader recently. The development board I use is MINI2440 with 128M NAND FLASH. I would like to ask if anyone here has made a bootloader with 128M NAND F...
lanqier396 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 254  1338  235  797  686  6  27  5  17  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号