K8AB-AS1-200-230VAC

Description
Industrial Relays 20-500mA 1-phs curre nt monitor
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size777KB,13 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric Compare View All

K8AB-AS1-200-230VAC Online Shopping

Suppliers Part Number Price MOQ In stock  
K8AB-AS1-200-230VAC - - View Buy Now

K8AB-AS1-200-230VAC Overview

Industrial Relays 20-500mA 1-phs curre nt monitor

K8AB-AS1-200-230VAC Parametric

Parameter NameAttribute value
Product CategoryIndustrial Relays
ManufacturerOMRON
RoHSNo
TypeCurrent Control Relay
Contact TerminationScrew
Contact FormSPDT (1 Form C)
Coil TerminationScrew
Coil TypeLatching
Mounting StyleDIN Rail
ApplicationIndustrial
ProductIndustrial
Factory Pack Quantity1
Unit Weight4.585615 oz
New Product
Single-phase Current Relay
K8AB-AS
Ideal for current monitoring for
industrial facilities and equipment.
• Monitor for overcurrents or undercurrents.
• Manual resetting and automatically resetting supported by one
Relay.
• Startup lock and operating time can be set separately.
• One SPDT output relay, 6 A at 250 VAC (resistive load).
• Output relay can be switched between normally open and
normally closed.
• Process control signal (4 to 20 mA) and commercial CT input
(0 to 1 A or 0 to 5 A) supported.
• Output status can be monitored using LED indicator.
• Inputs are isolated from the power supply.
Model Number Structure
Model Number Legend
K8AB-@@
1
2 3
4
1. Basic Model
K8AB:
Measuring and Monitoring Relays
2. Functions
AS:
Single-phase Current Relay (One-sided operation)
3. Measuring Current
1:
2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC
2:
0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC
3:
10 to 100 A AC, 20 to 200 A AC (See note.)
Note:
The K8AB-AS3 is specially designed to be used in combination with the OMRON K8AC-CT200L Current Transformer (CT). (Direct input is
not possible.)
4. Supply Voltage
24 VAC/DC: 24 VAC/DC
100-115 VAC: 100 to 115 VAC
200-230 VAC: 200 to 230 VAC
Ordering Information
List of Models
Single-phase Current Relay
Measuring current
2 to 20 mA AC/DC,
10 to 100 mA AC/DC,
50 to 500 mA AC/DC
0.1 to 1 A AC/DC,
0.5 to 5 A AC/DC,
0.8 to 8 A AC/DC
10 to 100 A AC,
20 to 200 A AC
(See note.)
Supply voltage
24 VAC/DC
100-115 VAC
200-230 VAC
24 VAC/DC
100-115 VAC
200-230 VAC
24 VAC/DC
100-115 VAC
Model
K8AB-AS1 24 VAC/DC
K8AB-AS1 100-115 VAC
K8AB-AS1 200-230 VAC
K8AB-AS2 24 VAC/DC
K8AB-AS2 100-115 VAC
K8AB-AS2 200-230 VAC
K8AB-AS3 24 VAC/DC
K8AB-AS3 100-115 VAC
200-230 VAC
K8AB-AS3 200-230 VAC
Note:
The K8AB-AS3 is designed to be used in combination with an OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not
possible.)
1

K8AB-AS1-200-230VAC Related Products

K8AB-AS1-200-230VAC K8AB-AS1-100-115VAC K8AB-AS3-200-230VAC K8AB-AS2-200-230VAC
Description Industrial Relays 20-500mA 1-phs curre nt monitor Industrial Relays 20-500mA 1-PHS CRT MONITOR Industrial Relays 100-200A 1-phs curre nt monitor Industrial Relays 1-8A 1-phase current monitor
Product Category Industrial Relays Industrial Relays Industrial Relays Industrial Relays
Manufacturer OMRON OMRON OMRON OMRON
RoHS No Details No No
Contact Termination Screw Screw Screw Screw
Contact Form SPDT (1 Form C) SPDT (1 Form C) SPDT (1 Form C) SPDT (1 Form C)
Coil Termination Screw Screw Screw Screw
Coil Type Latching Latching Latching Latching
Mounting Style DIN Rail DIN Rail DIN Rail DIN Rail
Application Industrial Industrial Industrial Industrial
Product Industrial Industrial Industrial Industrial
Factory Pack Quantity 1 1 1 1
Unit Weight 4.585615 oz 4.585615 oz 4.585615 oz 4.585615 oz
Type Current Control Relay Current Control Relay - Current Control Relay
Smart Home Password Lock
1.This password lock can complete the functions of measuring temperature, unlocking, timeout alarm, administrator decryption, password modification, and anti-pry alarm.2.In addition, users can choose ...
kevinrobot Microcontroller MCU
IQ Format
Is there any article that specifically introduces the algorithm, format, programming, and function of IQ in the Instaspin foc motor driver? I've been so confused recently. :faint:...
Mavine TI Technology Forum
Catalog of Safety Technology Prevention Training Materials
*******************************Table of Contents*********************************** Chapter 1 Overview of Security Technology Prevention Section 1 Importance of Technical Prevention 1. What is technic...
zcgzanne Industrial Control Electronics
Sign up now to win wonderful gifts! -2014 Spring Seminar Series
In 2014, Texas Instruments (TI) is ready to launch a spring technical seminar with eight stops in southern China and eastern China. The new series of solutions for industrial, medical, automotive, and...
EEWORLD社区 TI Technology Forum
Solutions to common problems in LED power supply product glue filling
Problems that may occur during the potting process of two-component potting glue: The main agent is too soft after curing/the surface is too sticky. The first method is to quickly cure at 60-80℃ for 1...
探路者 LED Zone
Operational Amplifier Used as Integrator
[align=left][color=rgb(82, 82, 82)][font=Arial, sans-serif][size=12px]In the first article of this series, “Operational Amplifiers—Basic Building Blocks” (link below), the transfer function of an oper...
wstt Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1228  1997  1104  892  978  25  41  23  18  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号