Hisense KFR-25GW-06BP inverter air conditioner indoor fan motor drive circuit
Source: InternetPublisher:拳制龙 Keywords: Hisense motor drive circuit inverter air conditioner Updated: 2020/10/16
Shown is the Hisense KlrR25GW/06BP variable frequency kiln regulator indoor fan motor drive circuit . As can be seen from the figure, the indoor fan
motor is powered by an AC 220 V power supply. The L end of the AC input circuit is connected to the common end of the motor through TLP361.
The live wire (N) of the AC 220 V input is added to the motor's running winding, and then The starting capacitor C is added to the starting winding of the motor. Only when the thyristor in TLP361
is turned on can voltage be added to the motor winding. The thyristor in TLP361 is controlled by the light-emitting diode. When the light-emitting diode
emits light, the thyristor turns on and current flows.
- How to use a microcontroller to control a servo motor?
- What are the challenges in designing a permanent magnet linear generator?
- A small improvement to the temperature and water level indicator alarm
- Working principle of ZNB-S digital display intelligent motor protector control circuit
- Motor self-starting circuit
- IGBT modules block overcurrent by controlling the gate
- Design and analysis of voice control circuit
- Home wireless burglar alarm circuit
- Precious home appliance anti-theft alarm
- Homemade anti-theft watchdog
- Egg heating control circuit
- Multi-channel patrol detection control circuit c
- Multi-channel patrol detection control circuit a
- Remote control receiving circuit of Panasonic inverter air conditioner indoor unit control circuit
- Micro remote control receiving and control circuit
- Ringtone control circuit
- Assembly line outage monitoring circuit
- Internal functional block diagram and external circuit of Hisense KFR-25GW-06BP inverter air conditioner indoor unit microprocessor
- Bedside touch light detection control circuit
- Water dispenser (Aucma) temperature detection control circuit